<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>63487</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>lecture</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Lithium isotope fractionation as a diagnostic tool for aging lithium-ion batteries</title>
    <abstract language="eng">Lithium-ion batteries (LIBs) are central to modern energy storage technologies, powering applications from portable electronics to electric vehicles and grid storage systems. Their popularity comes from their high energy density, efficiency, and extended cycle life. However, over time, various aging mechanisms lead to capacity loss, increased internal resistance, and, ultimately, battery failure. Understanding and predicting these aging processes is crucial for enhancing the reliability and longevity of LIBs. This necessity makes the development of advanced diagnostic tools essential.&#13;
&#13;
This study uses plasma-based spectrometry techniques to explore lithium isotope fractionation (LIF) as a predictive tool for monitoring LIB aging and degradation. Mass spectrometric techniques —including MC-ICP-MS, LA-ICP-MS, and MICAP-MS— were employed to analyze lithium isotopic composition in both new and aged lithium cobalt oxide (LCO) cells, including lab-made coin cells and commercial batteries.&#13;
&#13;
An isotopic fractionation was identified during electrochemical cycling: 6Li migrates towards the anode, while 7Li accumulates in the cathode. These isotopic patterns correlate with structural degradation, including solid electrolyte interphase (SEI) growth and crack formation, as confirmed by FIB-SEM, XANES, and EXAFS analyses. This correlation demonstrates that LIF aligns with key aging mechanisms in model coin cells and commercial batteries, such as capacity fade and impedance growth. LIF provides a powerful diagnostic tool for battery health monitoring and aging prediction by linking isotopic fractionation to structural degradation. This approach offers significant potential to extend battery lifespan and improve the reliability of energy storage systems.</abstract>
    <enrichment key="eventName">ANAKON 2025</enrichment>
    <enrichment key="eventPlace">Leipzig, Germany</enrichment>
    <enrichment key="eventStart">10.03.2025</enrichment>
    <enrichment key="eventEnd">13.03.2025</enrichment>
    <enrichment key="InvitedTalks">0</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>Carlos Enrique Abad Andrade</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Isotope</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Lithium</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Battery aging</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Degradation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Fractionation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Battery</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.1 Anorganische Spurenanalytik</collection>
    <collection role="institutes" number="">1.6 Anorganische Referenzmaterialien und Gasanalytik</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Elektrische Energiespeicher und -umwandlung</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="themenfelder" number="">Chemische Charakterisierung und Spurenanalytik</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Präsentation</collection>
  </doc>
  <doc>
    <id>59866</id>
    <completedYear/>
    <publishedYear>2024</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>3117</pageFirst>
    <pageLast>3125</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>article</type>
    <publisherName>Springer</publisherName>
    <publisherPlace>Berlin</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Determination of calcium, iron, and selenium in human serum by isotope dilution analysis using nitrogen microwave inductively coupled atmospheric pressure plasma mass spectrometry (MICAP-MS)</title>
    <abstract language="eng">In this study, we demonstrate the applicability of nitrogen microwave inductively coupled atmospheric pressure mass spectrometry (MICAP-MS) for Ca, Fe, and Se quantification in human serum using isotope dilution (ID) analysis. The matrix tolerance of MICAP-MS in Na matrix was investigated, uncovering that high Na levels can suppress the signal intensity. This suppression is likely due to the plasma loading and the space charge effect. Moreover, 40Ca and 44Ca isotopic fractionation was noted at elevated Na concentration. Nine certified serum samples were analyzed using both external calibration and ID analysis. Overestimation of Cr, Zn, As, and Se was found in the results of external calibration, which might be resulted from C-induced polyatomic interference and signal enhancement, respectively. Further investigations performed with methanol showed a similar enhancement effect for Zn, As, and Se, potentially supporting this assumption. The mass concentrations determined with ID analysis show metrological compatibility with the reference values, indicating that MICAP-MS combined with ID analysis can be a promising method for precise Ca, Fe, and Se determination. Moreover, this combination reduces the influences of matrix effects, broadening the applicability of MICAP-MS for samples with complex matrix.</abstract>
    <parentTitle language="eng">Analytical and bioanalytical chemistry</parentTitle>
    <identifier type="doi">10.1007/s00216-024-05274-0</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-598664</identifier>
    <identifier type="issn">1618-2642</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="date_peer_review">18.04.2024</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Zengchao You</author>
    <author>Alexander Winckelmann</author>
    <author>Jochen Vogl</author>
    <author>Sebastian Recknagel</author>
    <author>Carlos Enrique Abad Andrade</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Selenium</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Nitrogen microwave inductively coupled atmospheric pressure mass spectrometry</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Isotope dilution</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Human serum</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Calcium</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Iron</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.1 Anorganische Spurenanalytik</collection>
    <collection role="institutes" number="">1.6 Anorganische Referenzmaterialien und Gasanalytik</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="themenfelder" number="">Chemische Charakterisierung und Spurenanalytik</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/59866/216_2024_5274_MOESM1_ESM.pdf</file>
    <file>https://opus4.kobv.de/opus4-bam/files/59866/You-et-al_Ca-Fe-Se-in-Serum-IDMS-MICAP-MS_ABC-2024.pdf</file>
  </doc>
  <doc>
    <id>52716</id>
    <completedYear/>
    <publishedYear>2021</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>poster</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Central project for biochemical analysis of proteoglycans and glycosaminoglycans and for element-specific microscopy</title>
    <abstract language="eng">Nearly all disease processes are associated with variations of components of the extracellular matrix (ECM) that are typically observed during the development of inflammation. This concerns for example proteoglycans and their associated glycosaminoglycans (GAG), which have been shown to bind to cationic metal imaging probes due to their strong complexing activity. The complexing activity largely depends on the degree of GAG sulfation and/or carboxylation as well as on the GAG isomericity. In this central project, we investigate GAG structures from inflammatory disorders (namely cardiovascular diseases, inflammatory intestinal diseases and neuroinflammation) provided by researchers of the Collaborative Research Center at the molecular disaccharidic level using chromatographic and mass spectrometric methods. In parallel, the spatial localization and quantification of metal-based imaging probes are evaluated by LA-ICP-MS imaging.</abstract>
    <enrichment key="eventName">1st International Symposium In vivo Visualization of Extracellular Matrix Pathology</enrichment>
    <enrichment key="eventPlace">Online Meeting</enrichment>
    <enrichment key="eventStart">27.05.2021</enrichment>
    <enrichment key="eventEnd">28.05.2021</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>V. Blanchard</author>
    <author>Heike Traub</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Laser ablation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>ICP-MS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>MALDI</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.1 Anorganische Spurenanalytik</collection>
    <collection role="institutes" number="">1.6 Anorganische Referenzmaterialien und Gasanalytik</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="themenfelder" number="">Chemische Charakterisierung und Spurenanalytik</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Präsentation</collection>
  </doc>
  <doc>
    <id>53966</id>
    <completedYear/>
    <publishedYear>2021</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>lecture</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Recent Trends in Inexpensive Lithium Isotopic Analysis</title>
    <abstract language="eng">Lithium exists in two stable isotopes, 6Li and 7Li. The ratio of these in every ore varies depending on the geological history of the sample, thus providing a tool for fingerprinting the distinct origin of Li containing samples. Determination of the exact isotope ratio for e.g. designation of provenance today relies on expensive and bulky instrumentation such as multi `collector inductively coupled plasma mass spectrometry` (MC-ICP-MS). These instruments, however, are known to bear pitfalls in the characterization of particular elements including Lithium. BAM recently developed two alternative analytical devices for this task, solely relying on inexpensive optical spectroscopy in combination with state-of-the-art multivariate data analysis such as Machine learning algorithms. Both techniques have been comprehensively studied using certified reference materials and comparing the results to MC-ICP-MS results and could be shown to result in comparable figures of merit, paving the way for a more general accessibility to provenance determination instrumentation. The results also pave the way towards even further simplification of the laboratory infrastructure demands and to further include additional elements into the isotopic fingerprinting methodology.</abstract>
    <enrichment key="eventName">Lithium-Days</enrichment>
    <enrichment key="eventPlace">Halle, Germany</enrichment>
    <enrichment key="eventStart">06.12.2021</enrichment>
    <enrichment key="eventEnd">08.12.2021</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <enrichment key="InvitedTalks">0</enrichment>
    <author>Jens Riedel</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Lithium</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Isotopes</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Optical Spectroscopy</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.1 Anorganische Spurenanalytik</collection>
    <collection role="institutes" number="">1.3 Instrumentelle Analytik</collection>
    <collection role="institutes" number="">1.6 Anorganische Referenzmaterialien und Gasanalytik</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Elektrische Energiespeicher und -umwandlung</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Präsentation</collection>
  </doc>
  <doc>
    <id>52074</id>
    <completedYear/>
    <publishedYear>2021</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>106039</pageFirst>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume>176</volume>
    <type>article</type>
    <publisherName>Elsevier B.V.</publisherName>
    <publisherPlace>Amsterdam</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Calibration capacity of hot-pressed hydrogen standards for glow discharge optical emission and mass spectrometry</title>
    <abstract language="eng">Mixed copper and titanium hydride powder was hot-pressed and characterized by Carrier Gas Hot Extraction, XRay Diffraction, Thermal Gravimetric Analysis coupled with Mass Spectrometry, and Scanning Electron Microscopy.&#13;
The hot-pressed and five conventional samples were applied for calibration of hydrogen in Glow Discharge Optical Emission and Mass Spectrometry. Up to the introduction of 15 ng/s hydrogen the Emission yield model is useful in Glow Discharge Optical Emission Spectrometry. A correlation between saturation and even reversal of the emission yield of the spectral lines H121, H486 and H656 and low sputtering rates was found. Hydrogen effects exist for the spectral lines of Cu(II) 219 and Ti(I) 399. In Glow Discharge Mass Spectrometry, a linear dependency of the 1H ion current on the sputtered mass per time exists over the total range of hydrogen content investigated. Hydrogen effects also exist for the sensitivity of 48Ti and 63Cu. The sputtering rate of two-phase materials depends linearly on the sputtered mass per time of one phase, which allows the sputtering rate of two-phase materials with known composition to be predicted.</abstract>
    <parentTitle language="eng">Spectrochimica Acta Part B: Atomic Spectroscopy</parentTitle>
    <identifier type="doi">10.1016/j.sab.2020.106039</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="date_peer_review">18.03.2021</enrichment>
    <author>V. Hoffmann</author>
    <author>M. Uhlemann</author>
    <author>Silke Richter</author>
    <author>jens Pfeifer</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Hot-pressing</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>GD-OES</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>GD-MS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Calibration</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Hydrogen</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Titanium hydride</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Sputtering</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Two-phase system</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.1 Anorganische Spurenanalytik</collection>
    <collection role="institutes" number="">1.6 Anorganische Referenzmaterialien und Gasanalytik</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="themenfelder" number="">Chemische Charakterisierung und Spurenanalytik</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
  </doc>
  <doc>
    <id>53244</id>
    <completedYear/>
    <publishedYear>2021</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>251</pageFirst>
    <pageLast>256</pageLast>
    <pageNumber/>
    <edition/>
    <issue>1</issue>
    <volume>414</volume>
    <type>article</type>
    <publisherName>Springer</publisherName>
    <publisherPlace>Berlin</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Determination of lithium in human serum by isotope dilution atomic absorption spectrometry</title>
    <abstract language="eng">The therapeutic dose of lithium (Li) compounds, which are widely used for the treatment of psychiatric and hematologic disorders, is close to its toxic level; therefore, drug monitoring protocols are mandatory. Herein, we propose a fast, simple, and low-cost analytical procedure for the traceable determination of Li concentration in human serum, based on the monitoring of the Li isotope dilution through the partially resolved isotope shift in its electronic transition around 670.80 nm using a commercially available high-resolution continuum source graphite furnace atomic absorption spectrometer. With this technique, serum samples only require acidic digestion before analysis. The procedure requires three measurements—an enriched 6Li spike, a mixture of a certified standard solution and spike, and a mixture of the sample and spike with a nominal 7Li/6Li ratio of 0.82. Lanthanum has been used as an internal spectral standard for wavelength correction. The spectra are described as the linear superposition of the contributions of the respective isotopes, each consisting of a spin-orbit doublet, which can be expressed as Gaussian components with constant spectral position and width and different relative intensity, reflecting the isotope ratio in the sample. Both the spectral constants and the correlation between isotope ratio and relative band intensity have been experimentally obtained using commercially available materials enriched with Li isotopes. The Li characteristic mass (mc) obtained corresponds to 0.6 pg. The procedure has been validated using five human serum certified reference materials. The results are metrologically comparable and compatible to the certified values. The measurement uncertainties are comparable to those obtained by the more complex and expensive technique, isotope dilution mass spectrometry.</abstract>
    <parentTitle language="eng">Analytical and bioanalytical chemistry</parentTitle>
    <identifier type="doi">10.1007/s00216-021-03636-6</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-532446</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="date_peer_review">22.09.2021</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Alexander Winckelmann</author>
    <author>Dalia Morcillo Garcia-Morato</author>
    <author>Silke Richter</author>
    <author>Sebastian Recknagel</author>
    <author>Jens Riedel</author>
    <author>Jochen Vogl</author>
    <author>Ulrich Panne</author>
    <author>Carlos Enrique Abad Andrade</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Lithium</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Human serum</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Isotope dilution</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Atomic absorption spectrometry</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>High-resolution continuum source graphite furnace atomic absorption spectrometry</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="institutes" number="">P Präsident</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.1 Anorganische Spurenanalytik</collection>
    <collection role="institutes" number="">1.3 Instrumentelle Analytik</collection>
    <collection role="institutes" number="">1.6 Anorganische Referenzmaterialien und Gasanalytik</collection>
    <collection role="institutes" number="">S Qualitätsinfrastruktur</collection>
    <collection role="institutes" number="">S.1 Qualität im Prüfwesen</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="themenfelder" number="">Chemische Charakterisierung und Spurenanalytik</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <collection role="institutes" number="">P.0 Präsident und andere</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/53244/Winckelmann-et-al_Li-in-Serum-IDAAs_ABC_2022.pdf</file>
  </doc>
  <doc>
    <id>53028</id>
    <completedYear/>
    <publishedYear>2021</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>10022</pageFirst>
    <pageLast>10030</pageLast>
    <pageNumber/>
    <edition/>
    <issue>29</issue>
    <volume>93</volume>
    <type>article</type>
    <publisherName>American Chemical Society</publisherName>
    <publisherPlace>Washington, DC, USA</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">High-Resolution Atomic Absorption Spectrometry Combined With Machine Learning Data Processing for Isotope Amount Ratio Analysis of Lithium</title>
    <abstract language="eng">An alternative method for lithium isotope amount ratio analysis based on a combination of high-resolution atomic absorption spectrometry and spectral data analysis by machine learning (ML) is proposed herein. It is based on the well-known isotope shift of approximately 15 pm for the electronic transition 22P←22S at around the wavelength of 670.8 nm, which can be measured by the state-of-the-art high-resolution continuum source graphite furnace atomic absorption spectrometry. For isotope amount ratio analysis, a scalable tree boosting ML algorithm (XGBoost) was employed and calibrated using a set of samples with 6Li isotope amount fractions, ranging from 0.06 to 0.99 mol mol–1, previously determined by a multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS). The calibration ML model was validated with two certified reference materials (LSVEC and IRMM-016). The procedure was applied toward the isotope amount ratio determination of a set of stock chemicals (Li2CO3, LiNO3, LiCl, and LiOH) and a BAM candidate reference material NMC111 (LiNi1/3Mn1/3Co1/3O2), a Li-battery cathode material. The results of these determinations were compared with those obtained by MC-ICP-MS and found to be metrologically comparable and compatible. The residual bias was −1.8‰, and the precision obtained ranged from 1.9 to 6.2‰. This precision was sufficient to resolve naturally occurring variations, as demonstrated for samples ranging from approximately −3 to +15‰. To assess its suitability to technical applications, the NMC111 cathode candidate reference material was analyzed using high-resolution continuum source atomic absorption spectrometry with and without matrix purification. The results obtained were metrologically compatible with each other.</abstract>
    <parentTitle language="eng">Analytical Chemistry</parentTitle>
    <identifier type="issn">1520-6882</identifier>
    <identifier type="doi">10.1021/acs.analchem.1c00206</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="date_peer_review">28.07.2021</enrichment>
    <author>Alexander Winckelmann</author>
    <author>S. Nowak</author>
    <author>Silke Richter</author>
    <author>Sebastian Recknagel</author>
    <author>Jens Riedel</author>
    <author>Jochen Vogl</author>
    <author>Ulrich Panne</author>
    <author>Carlos Enrique Abad Andrade</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Lithium</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Isotope</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Machine learning</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Algorithms</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Reference material</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>AAS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Atomic Absorption Spectrometry</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="institutes" number="">P Präsident</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.1 Anorganische Spurenanalytik</collection>
    <collection role="institutes" number="">1.3 Instrumentelle Analytik</collection>
    <collection role="institutes" number="">1.6 Anorganische Referenzmaterialien und Gasanalytik</collection>
    <collection role="institutes" number="">S Qualitätsinfrastruktur</collection>
    <collection role="institutes" number="">S.1 Qualität im Prüfwesen</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Elektrische Energiespeicher und -umwandlung</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="themenfelder" number="">Chemische Charakterisierung und Spurenanalytik</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <collection role="institutes" number="">P.0 Präsident und andere</collection>
    <collection role="institutes" number="">PST Präsidiale Stabsstelle</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
  </doc>
  <doc>
    <id>61180</id>
    <completedYear/>
    <publishedYear>2024</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>5</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume>220</volume>
    <type>article</type>
    <publisherName>Elsevier BV</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Lithium isotope ratio analysis of geological samples using atomic absorption spectrometry with improved spectral resolution</title>
    <abstract language="eng">This study introduces an improved spectrometric method with enhanced precision to determine isotope ratios in geological samples without chromatographic separation. Firstly, the improvement is achieved by increasing the spectral resolution of the spectrometer applied in well-known high-resolution continuum source atomic absorption spectrometry (HR-CS-AAS). The resulting resolving power and linear dispersion of the upgraded setup, which is denoted in the following as HR+CS-AAS, is well adapted to the line widths of the Li isotope components we investigated. Secondly, our proposed method combines optical absorption spectrometry with machine learning data analysis using an extreme gradient boosting algorithm (XGBoost). This method was applied to analyze certified geological reference materials with δLSVEC(7Li/6Li) (hereafter δ7Li) values ranging from −0.5 ‰ to 4.5 ‰. With a pixel related optical resolving power of λ/∆λ ≈ 780 000, we obtain precisions in δ7Li measurements from 1.0 ‰ to 2.5 ‰. The method is validated by comparing the results with multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS), confirming its metrological compatibility. This work presents a fast, robust, and reliable method for δ7Li measurement in geological samples.</abstract>
    <parentTitle language="eng">Spectrochimica Acta Part B: Atomic Spectroscopy</parentTitle>
    <identifier type="doi">10.1016/j.sab.2024.107013</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-611807</identifier>
    <enrichment key="opus_doi_flag">true</enrichment>
    <enrichment key="opus_import_data">{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,15]],"date-time":"2024-09-15T00:13:15Z","timestamp":1726359195000},"reference-count":25,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,8,12]],"date-time":"2024-08-12T00:00:00Z","timestamp":1723420800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Spectrochimica Acta Part B: Atomic Spectroscopy"],"published-print":{"date-parts":[[2024,10]]},"DOI":"10.1016\/j.sab.2024.107013","type":"journal-article","created":{"date-parts":[[2024,8,3]],"date-time":"2024-08-03T00:18:25Z","timestamp":1722644305000},"page":"107013","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Lithium isotope ratio analysis of geological samples using atomic absorption spectrometry with improved spectral resolution"],"prefix":"10.1016","volume":"220","author":[{"given":"Dalia","family":"Morcillo","sequence":"first","affiliation":[]},{"given":"Alexander","family":"Winckelmann","sequence":"additional","affiliation":[]},{"given":"Daniel A.","family":"Frick","sequence":"additional","affiliation":[]},{"given":"Lars","family":"Jacobsen","sequence":"additional","affiliation":[]},{"given":"Tino","family":"Seger","sequence":"additional","affiliation":[]},{"given":"Stefan","family":"Florek","sequence":"additional","affiliation":[]},{"given":"Silke","family":"Richter","sequence":"additional","affiliation":[]},{"given":"Jochen","family":"Vogl","sequence":"additional","affiliation":[]},{"given":"Sebastian","family":"Recknagel","sequence":"additional","affiliation":[]},{"given":"Ulrich","family":"Panne","sequence":"additional","affiliation":[]},{"given":"Carlos","family":"Abad","sequence":"additional","affiliation":[]}],"member":"78","reference":[{"first-page":"202","year":"2022","series-title":"Mineral Commodity Summaries 2022: U.S. Geological Survey","author":"R. U.S. Geological Survey, Virginia: 2022","key":"10.1016\/j.sab.2024.107013_bb0005"},{"key":"10.1016\/j.sab.2024.107013_bb0010","doi-asserted-by":"crossref","DOI":"10.1088\/1748-9326\/aae9b1","article-title":"Socio-environmental impacts of lithium mineral extraction: towards a research agenda","volume":"13","author":"Agusdinata","year":"2018","journal-title":"Environ. Res. Lett."},{"key":"10.1016\/j.sab.2024.107013_bb0015","doi-asserted-by":"crossref","first-page":"4172","DOI":"10.1038\/s41467-022-31850-y","article-title":"Tracing the origin of lithium in li-ion batteries using lithium isotopes","volume":"13","author":"Desaulty","year":"2022","journal-title":"Nat. Commun."},{"key":"10.1016\/j.sab.2024.107013_bb0020","doi-asserted-by":"crossref","DOI":"10.1016\/j.jclepro.2022.131492","article-title":"Digital battery passports to enable circular and sustainable value chains: conceptualization and use cases","volume":"353","author":"Berger","year":"2022","journal-title":"J. Clean. Prod."},{"key":"10.1016\/j.sab.2024.107013_bb0025","series-title":"The minerals of Lithium, Elements","first-page":"235","volume":"16","author":"Grew","year":"2020"},{"key":"10.1016\/j.sab.2024.107013_bb0030","series-title":"Classification and characteristics of natural Lithium resources, Elements","first-page":"259","volume":"16","author":"Bowell","year":"2020"},{"key":"10.1016\/j.sab.2024.107013_bb0035","doi-asserted-by":"crossref","first-page":"153","DOI":"10.2138\/gsrmg.55.1.153","article-title":"Developments in the understanding and application of Lithium isotopes in the earth and planetary sciences","volume":"55","author":"Tomascak","year":"2004","journal-title":"Rev. Mineral. Geochem."},{"key":"10.1016\/j.sab.2024.107013_bb0040","doi-asserted-by":"crossref","first-page":"165","DOI":"10.2138\/rmg.2017.82.6","article-title":"Lithium isotope geochemistry","volume":"82","author":"Penniston-Dorland","year":"2017","journal-title":"Rev. Mineral. Geochem."},{"key":"10.1016\/j.sab.2024.107013_bb0045","doi-asserted-by":"crossref","first-page":"1711","DOI":"10.1016\/0016-7037(88)90239-6","article-title":"Variation of lithium isotope composition in the marine environment: a preliminary report","volume":"52","author":"Lui-Heung","year":"1988","journal-title":"Geochim. Cosmochim. Acta"},{"key":"10.1016\/j.sab.2024.107013_bb0050","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1002\/mas.20251","article-title":"Accurate and precise determination of isotopic ratios by MC-ICP-MS: a review","volume":"28","author":"Yang","year":"2009","journal-title":"Mass Spectrom. Rev."},{"key":"10.1016\/j.sab.2024.107013_bb0055","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1039\/C5JA00231A","article-title":"Accurate determination of lithium isotope ratios by MC-ICP-MS without strict matrix-matching by using a novel washing method","volume":"31","author":"Lin","year":"2016","journal-title":"J. Anal. At. Spectrom."},{"key":"10.1016\/j.sab.2024.107013_bb0060","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1016\/S0003-2670(01)95227-4","article-title":"The atomic absorption spectrometric determination of lithium isotope abundances by direct measurement of the absorbance ratio","volume":"116","author":"Chapman","year":"1980","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.sab.2024.107013_bb0065","article-title":"Lithium isotope measurement using laser-induced breakdown spectroscopy and Chemometrics","volume":"3702820953205","author":"Wood","year":"2020","journal-title":"Appl. Spectrosc."},{"key":"10.1016\/j.sab.2024.107013_bb0070","doi-asserted-by":"crossref","first-page":"105868","DOI":"10.1016\/j.sab.2020.105868","article-title":"Laser-induced breakdown self-reversal isotopic spectrometry for isotopic analysis of lithium","volume":"168","author":"Touchet","year":"2020","journal-title":"Spectrochim. Acta, Part B"},{"key":"10.1016\/j.sab.2024.107013_bb0075","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/j.sab.2017.08.012","article-title":"Determination of boron isotope ratios by high-resolution continuum source molecular absorption spectrometry using graphite furnace vaporizers","volume":"136","author":"Abad","year":"2017","journal-title":"Spectrochim. Acta B At. Spectrosc."},{"key":"10.1016\/j.sab.2024.107013_bb0080","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1016\/S0584-8547(00)00198-1","article-title":"Measurement of 7Li\/6Li isotope ratios by resonant Doppler-free two-photon diode laser atomic absorption spectroscopy in a low-pressure graphite furnace","volume":"55","author":"Wizemann","year":"2000","journal-title":"Spectrochim. Acta, Part B"},{"key":"10.1016\/j.sab.2024.107013_bb0085","doi-asserted-by":"crossref","first-page":"1131","DOI":"10.1016\/S0584-8547(98)00132-3","article-title":"A laser ablation\u2013atomic fluorescence technique for isotopically selective determination of lithium in solids","volume":"53","author":"Smith","year":"1998","journal-title":"Spectrochim. Acta, Part B"},{"key":"10.1016\/j.sab.2024.107013_bb0090","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1366\/11-06314","article-title":"Monitoring uranium, hydrogen, and Lithium and their isotopes using a compact laser-induced breakdown spectroscopy (LIBS) probe and high-resolution spectrometer","volume":"66","author":"Cremers","year":"2012","journal-title":"Appl. Spectrosc."},{"key":"10.1016\/j.sab.2024.107013_bb0120","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1177\/0003702820953205","article-title":"Lithium isotope measurement using laser-induced breakdown spectroscopy and Chemometrics","volume":"75","author":"Wood","year":"2020","journal-title":"Appl. Spectrosc."},{"key":"10.1016\/j.sab.2024.107013_bb0095","doi-asserted-by":"crossref","first-page":"10022","DOI":"10.1021\/acs.analchem.1c00206","article-title":"High-resolution atomic absorption spectrometry combined with machine learning data processing for isotope amount ratio analysis of Lithium","volume":"93","author":"Winckelmann","year":"2021","journal-title":"Anal. Chem."},{"key":"10.1016\/j.sab.2024.107013_bb0100","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1007\/s00216-021-03636-6","article-title":"Determination of lithium in human serum by isotope dilution atomic absorption spectrometry","volume":"414","author":"Winckelmann","year":"2022","journal-title":"Anal. Bioanal. Chem."},{"key":"10.1016\/j.sab.2024.107013_bb0105","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1039\/ja9951000145","article-title":"High-resolution spectrometer for atomic spectrometry","volume":"10","author":"Florek","year":"1995","journal-title":"J. Anal. At. Spectrom."},{"key":"10.1016\/j.sab.2024.107013_bb0125","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1111\/j.1751-908X.2005.tb00904.x","article-title":"GeoReM: a new geochemical database for reference materials and isotopic standards","volume":"29","author":"Jochum","year":"2005","journal-title":"Geostand. Geoanal. Res."},{"key":"10.1016\/j.sab.2024.107013_bb0110","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1111\/ggr.12327","article-title":"Intercalibration of mg Isotope Delta scales and realisation of SI traceability for mg isotope amount ratios and Isotope Delta values","volume":"44","author":"Vogl","year":"2020","journal-title":"Geostand. Geoanal. Res."},{"key":"10.1016\/j.sab.2024.107013_bb0130","doi-asserted-by":"crossref","DOI":"10.1016\/j.sab.2020.106051","article-title":"Isotopic analysis and plasma diagnostics for lithium detection using combined laser ablation\u2013tuneable diode laser absorption spectroscopy and laser-induced breakdown spectroscopy","volume":"177","author":"Hull","year":"2021","journal-title":"Spectrochim. Acta, Part B"}],"container-title":["Spectrochimica Acta Part B: Atomic Spectroscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0584854724001575?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0584854724001575?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,9,14]],"date-time":"2024-09-14T00:55:12Z","timestamp":1726275312000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0584854724001575"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10]]},"references-count":25,"alternative-id":["S0584854724001575"],"URL":"http:\/\/dx.doi.org\/10.1016\/j.sab.2024.107013","relation":{},"ISSN":["0584-8547"],"issn-type":[{"type":"print","value":"0584-8547"}],"subject":[],"published":{"date-parts":[[2024,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Lithium isotope ratio analysis of geological samples using atomic absorption spectrometry with improved spectral resolution","name":"articletitle","label":"Article Title"},{"value":"Spectrochimica Acta Part B: Atomic Spectroscopy","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.sab.2024.107013","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Authors. Published by Elsevier B.V.","name":"copyright","label":"Copyright"}],"article-number":"107013"}}</enrichment>
    <enrichment key="local_crossrefDocumentType">journal-article</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <enrichment key="date_peer_review">07.10.2024</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Dalia Morcillo</author>
    <author>Alexander Winckelmann</author>
    <author>Daniel A. Frick</author>
    <author>Lars Jacobsen</author>
    <author>Tino Seger</author>
    <author>Stefan Florek</author>
    <author>Silke Richter</author>
    <author>Jochen Vogl</author>
    <author>Sebastian Recknagel</author>
    <author>Ulrich Panne</author>
    <author>Carlos Enrique Abad Andrade</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Isotope</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>High-resolution continuum source atomic absorption spectroscopy</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Lithium</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Machine learning</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Echelle spectrometer</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="institutes" number="">P Präsident</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.1 Anorganische Spurenanalytik</collection>
    <collection role="institutes" number="">1.6 Anorganische Referenzmaterialien und Gasanalytik</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="themenfelder" number="">Chemische Charakterisierung und Spurenanalytik</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <collection role="institutes" number="">P.0 Präsident und andere</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/61180/1-s2.0-S0584854724001575-main.pdf</file>
  </doc>
  <doc>
    <id>53693</id>
    <completedYear/>
    <publishedYear>2021</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>poster</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Atomic absorption spectrometry with machine learning as a tool for lithium isotope analysis</title>
    <abstract language="eng">The general interest in the implementation of renewable energies, particularly in the development of lithium-ion batteries, makes lithium a key element to be analyzed. We are working to develop this tool to determine if the isotopic effect of lithium has an impact on battery aging.</abstract>
    <enrichment key="eventName">SALSA Konferenz</enrichment>
    <enrichment key="eventPlace">Berlin, Germany</enrichment>
    <enrichment key="eventStart">16.09.2021</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>Dalia Morcillo</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Atomic absorption spectrometry</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Battery</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Machine learning</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Lithium</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Isotope</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="institutes" number="">P Präsident</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.1 Anorganische Spurenanalytik</collection>
    <collection role="institutes" number="">1.3 Instrumentelle Analytik</collection>
    <collection role="institutes" number="">1.6 Anorganische Referenzmaterialien und Gasanalytik</collection>
    <collection role="institutes" number="">S Qualitätsinfrastruktur</collection>
    <collection role="institutes" number="">S.1 Qualität im Prüfwesen</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="themenfelder" number="">Chemische Charakterisierung und Spurenanalytik</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Präsentation</collection>
    <collection role="institutes" number="">P.0 Präsident und andere</collection>
  </doc>
  <doc>
    <id>53686</id>
    <completedYear/>
    <publishedYear>2021</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>poster</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Lithium isotope analysis combining atomic absorption spectroscopy and machine learning</title>
    <abstract language="eng">In this poster for the SCIX Conference, we apply an analytical procedure based on the monitoring of the lithium isotope through the partially resolved isotope shift in the electronic transition 22P&lt;-22S around wavelength 670.80 nm using high-resolution continuum source atomic absorption spectrometer (HR-CS-AAS) in combination with machine learning (ML) for the determination of Li Isotope ratio analysis.</abstract>
    <enrichment key="eventName">SCIX Conference</enrichment>
    <enrichment key="eventPlace">Providence, RI, USA</enrichment>
    <enrichment key="eventStart">26.09.2021</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>Dalia Morcillo</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Lithium isotope</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>High-resolution continuum source atomic absorption spectrometer</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Machine learning</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="institutes" number="">P Präsident</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.1 Anorganische Spurenanalytik</collection>
    <collection role="institutes" number="">1.3 Instrumentelle Analytik</collection>
    <collection role="institutes" number="">1.6 Anorganische Referenzmaterialien und Gasanalytik</collection>
    <collection role="institutes" number="">S Qualitätsinfrastruktur</collection>
    <collection role="institutes" number="">S.1 Qualität im Prüfwesen</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="themenfelder" number="">Chemische Charakterisierung und Spurenanalytik</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Präsentation</collection>
    <collection role="institutes" number="">P.0 Präsident und andere</collection>
  </doc>
  <doc>
    <id>52800</id>
    <completedYear/>
    <publishedYear>2021</publishedYear>
    <thesisYearAccepted/>
    <language>deu</language>
    <pageFirst>64</pageFirst>
    <pageLast>67</pageLast>
    <pageNumber/>
    <edition/>
    <issue>Juni</issue>
    <volume>69</volume>
    <type>article</type>
    <publisherName>Wiley-VCH</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="deu">Mehr Analyten, kleinere Proben</title>
    <abstract language="deu">Molekülmassenspektrometrie entwickelt sich weg von klassischer Target- hin zu Nontarget-Analytik. Elementmassenspektrometrie liefert hohe Ortsauflösung beim Element-Imaging und analysiert einzelne Zellen. Aufgrund der Fortschritte bei den Geräten für Timeof-Flight-Massenspektrometrie mit induktiv gekoppeltem Plasma (ICPToF-MS) lässt sich das gesamte Periodensystem der Elemente in kurzen transienten Signalen quasi-simultan massenspektrometrisch erfassen.</abstract>
    <parentTitle language="deu">Nachrichten aus der Chemie</parentTitle>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>Björn Meermann</author>
    <author>Jan Lisec</author>
    <author>Carsten Jaeger</author>
    <author>Jessica Saatz</author>
    <author>Heike Traub</author>
    <author>Marcus von der Au</author>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Massenspektrometrie</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Non-target</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>ICP-ToF-MS</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Laser Ablation/Imaging</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.1 Anorganische Spurenanalytik</collection>
    <collection role="institutes" number="">1.6 Anorganische Referenzmaterialien und Gasanalytik</collection>
    <collection role="institutes" number="">1.7 Organische Spuren- und Lebensmittelanalytik</collection>
    <collection role="institutes" number="">1.8 Umweltanalytik</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="themenfelder" number="">Chemische Charakterisierung und Spurenanalytik</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
  </doc>
  <doc>
    <id>64377</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>11</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>article</type>
    <publisherName>Royal Society of Chemistry (RSC)</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Exploring Age-Induced Lithium Isotope Fractionation in Lithium-Ion Batteries using Microwave-Induced Cold Nitrogen Plasma Mass Spectrometry</title>
    <abstract language="eng">This study explores Microwave-Inductively Coupled Atmospheric-pressure Plasma Mass Spectrometry (MICAP-MS) as a cost-effective alternative to Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS) for analyzing lithium isotopic composition in lithium-ion batteries (LIBs). We investigate the performance of MICAP-MS in measuring Li isotope ratios in new and aged commercial lithium cobalt oxide (LCO) batteries. Our results show that MICAP-MS, operating under cold plasma conditions at 800 W with an 8 mm torch position, achieves results metrologically compatible with MC-ICP-MS, with a precision ranging from 0.6‰ to 3.4‰ for δ7Li values. MICAP-MS benefits from a dielectric resonator for uniform plasma, better ion velocity control, and higher energy efficiency. Optimal settings were identified with dwell times of 10 ms for 6Li and 1 ms for 7Li. The study of LIBs revealed that 6Li migrates towards the anode over multiple charge–discharge cycles, causing 7Li to accumulate in the cathode, a fractionation effect that becomes more pronounced with prolonged cycling. MICAP-MS provides a cost-effective, precise alternative to MC-ICP-MS, with lower operational costs and enhanced portability, advancing the study of isotopic fractionation and aging in lithium-ion batteries.</abstract>
    <parentTitle language="eng">Journal of Analytical Atomic Spectrometry</parentTitle>
    <identifier type="issn">0267-9477</identifier>
    <identifier type="doi">10.1039/d4ja00324a</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-643777</identifier>
    <enrichment key="opus_doi_flag">true</enrichment>
    <enrichment key="local_crossrefDocumentType">journal-article</enrichment>
    <enrichment key="local_crossrefLicence">http://creativecommons.org/licenses/by/3.0/</enrichment>
    <enrichment key="local_import_origin">crossref</enrichment>
    <enrichment key="local_doiImportPopulated">PersonAuthorFirstName_1,PersonAuthorLastName_1,PersonAuthorFirstName_2,PersonAuthorLastName_2,PersonAuthorFirstName_3,PersonAuthorLastName_3,PersonAuthorFirstName_4,PersonAuthorLastName_4,PersonAuthorFirstName_5,PersonAuthorLastName_5,PersonAuthorFirstName_6,PersonAuthorLastName_6,PersonAuthorFirstName_7,PersonAuthorLastName_7,PersonAuthorFirstName_8,PersonAuthorLastName_8,PersonAuthorFirstName_9,PersonAuthorLastName_9,PersonAuthorFirstName_10,PersonAuthorLastName_10,PublisherName,TitleMain_1,Language,TitleAbstract_1,TitleParent_1,PublishedYear,IdentifierIssn,Enrichmentlocal_crossrefLicence</enrichment>
    <enrichment key="opus.source">doi-import</enrichment>
    <enrichment key="date_peer_review">27.10.2025</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Dalia Morcillo</author>
    <author>Alexander Winckelmann</author>
    <author>Marcus Oelze</author>
    <author>Robert Leonhardt</author>
    <author>Anita Schmidt</author>
    <author>Silke Richter</author>
    <author>Sebastian Recknagel</author>
    <author>Jochen Vogl</author>
    <author>Ulrich Panne</author>
    <author>Carlos Enrique Abad Andrade</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>MICAP-MS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Lithium</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Battery aging</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Lithium isotopes</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Nitrogen plasma</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Isotope fractionation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>lithium cobalt oxide</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LCO</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="institutes" number="">P Präsident</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.1 Anorganische Spurenanalytik</collection>
    <collection role="institutes" number="">1.6 Anorganische Referenzmaterialien und Gasanalytik</collection>
    <collection role="institutes" number="">3 Gefahrgutumschließungen; Energiespeicher</collection>
    <collection role="institutes" number="">3.1 Sicherheit von Gefahrgutverpackungen und Batterien</collection>
    <collection role="institutes" number="">S Qualitätsinfrastruktur</collection>
    <collection role="institutes" number="">S.1 Qualität im Prüfwesen</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Elektrische Energiespeicher und -umwandlung</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="themenfelder" number="">Chemische Charakterisierung und Spurenanalytik</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <collection role="institutes" number="">P.0 Präsident und andere</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/64377/Morcillo_et_al_2025.pdf</file>
    <file>https://opus4.kobv.de/opus4-bam/files/64377/Supporting_information_Morcillo_et_al_2025.pdf</file>
  </doc>
  <doc>
    <id>64879</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>lecture</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Tracking Lithium-Ion Battery Ageing via Lithium Isotope Fractionation</title>
    <abstract language="eng">Lithium-ion batteries power portable devices, electric vehicles, and stationary power grids, yet hidden aging reactions still shorten their service life and raise concerns about cost and safety. An analytical proxy is needed to report these reactions and accelerate product development, quality control, and recycling. Here, we demonstrate that subtle shifts in the natural 7Li/6Li ratio accurately record the two decisive stages of cell aging, solid-electrolyte interphase (SEI) formation and field-driven aging, which can be detected using multi-collector ICP-MS.&#13;
Because Li is easily stripped from digested electrodes or electrolyte in a one-step cation-exchange column, high-purity solutions reach the spectrometer in minutes. A streamlined MC-ICP-MS run yields a δ7LiLSVEC precision of 0.4 ‰, enabling dozens of battery fractions to be analyzed per day.&#13;
Applying the workflow to LiCoO2 coin cells as models, sampled from pristine to 700 cycles, reveals a clear isotopic narrative. During the first ≈45 cycles, 7Li leaves the LiCoO2 lattice, dissolves into the electrolyte, and is locked in the SEI on graphite, driving cathode δ7Li from +8 to –10 ‰ and raising the anode to +13 ‰ while capacity drops by 10 %. After the interphase matures, the electric field takes over: the lighter 6Li migrates faster to the anode, 7Li accumulates in the contracting Li1-xCoO2 lattice, and the bulk separation factor rises to α≈1.045 by 700 cycles. The δ7Li curve flattens roughly 70 cycles before capacity falls to 80%, providing an early warning of end-of-life. Isotopic gradients scale linearly with impedance growth, SEI thickness, and crack density confirmed by LA-ICP-MS mapping, FIB-SEM, XANES, and EXAFS.&#13;
Although each data point requires one cell, lithium-isotope fractionation provides direct, element-specific, and structural fatigue insight unavailable from non-destructive tests. The straightforward chemistry and fast MC-ICP-MS routine make the approach practical for targeted aging studies, additive screening, and forensic autopsies, complementing high-throughput electrochemical methods and supporting the design of longer-lived batteries.</abstract>
    <enrichment key="eventName">SciX 2025</enrichment>
    <enrichment key="eventPlace">Covington, KY, USA</enrichment>
    <enrichment key="eventStart">05.10.2025</enrichment>
    <enrichment key="eventEnd">10.10.2025</enrichment>
    <enrichment key="InvitedTalks">1</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>Carlos Enrique Abad Andrade</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Isotope</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Lithium</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>MC-ICP-MS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>MICAP-MS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Isotope fractionation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Battery</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.1 Anorganische Spurenanalytik</collection>
    <collection role="institutes" number="">1.6 Anorganische Referenzmaterialien und Gasanalytik</collection>
    <collection role="institutes" number="">6 Materialchemie</collection>
    <collection role="institutes" number="">6.3 Strukturanalytik</collection>
    <collection role="institutes" number="">S Qualitätsinfrastruktur</collection>
    <collection role="institutes" number="">S.1 Qualität im Prüfwesen</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Elektrische Energiespeicher und -umwandlung</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="themenfelder" number="">Chemische Charakterisierung und Spurenanalytik</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Präsentation</collection>
  </doc>
  <doc>
    <id>65094</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>19</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>preprint</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Lithium isotope fractionation as an early indicator of degradation mechanisms in lithium-ion batteries</title>
    <abstract language="eng">Aging in lithium-ion batteries (LIBs) degrades performance and hinders sustainability, demanding advanced diagnostics for early failure prediction. We investigate lithium isotope fractionation (LIF) as an innovative probe of degradation in lithium cobalt oxide (LCO) coin cells aged over 0−700 cycles. High-precision multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) quantified δ7Li variations across cell stages: non-cycled (0 cycles), newly formed (5 cycles), semi-aged (250 cycles), and fully aged (700 cycles). During early cycling (≤ 45 cycles), chemical processes drive 7Li enrichment at the anode (δ7Li vs LSVEC = +12 ‰) through solid electrolyte interphase (SEI) formation, while the cathode depletes in 7Li (δ7Li vs LSVEC = −0.7 ‰). Beyond 45 cycles, electric field-induced migration predominates, promoting 6Li intercalation into the anode and increasing the δ7Li of the cathode by 8.1 ‰. Mass balance verifies isotope conservation, attributing shifts to redistribution and trapping. Complementary electrochemical impedance spectroscopy (EIS) and X-ray absorption spectroscopy and diffraction confirm SEI expansion, cobalt oxidation, lattice shrinkage, and changes in electrode structure, corroborating LIF trends. Notably, a δ7Li inflection at approximately 270 cycles anticipates end-of-life by 70 cycles, surpassing traditional methods in sensitivity. LIF emerges as a predictive indicator of aging mechanisms, informing optimized designs for durable LIBs.</abstract>
    <parentTitle language="eng">ChemRxiv</parentTitle>
    <identifier type="doi">10.26434/chemrxiv-2025-16lvq</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-650945</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Dalia Morcillo</author>
    <author>Marcus Oelze</author>
    <author>Pranav Seena Prem</author>
    <author>Ana de Oliveira Guilherme Buzanich</author>
    <author>Franziska Emmerling</author>
    <author>Sebastian Recknagel</author>
    <author>Ulrich Panne</author>
    <author>Carlos Enrique Abad Andrade</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Lithium isotope fractionation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Lithium-ion batteries</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Degradation mechanisms</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LiCoO2 cathodes</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LCO</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Isotopic tracing</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Lithium isotopes</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="institutes" number="">P Präsident</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.1 Anorganische Spurenanalytik</collection>
    <collection role="institutes" number="">1.6 Anorganische Referenzmaterialien und Gasanalytik</collection>
    <collection role="institutes" number="">6 Materialchemie</collection>
    <collection role="institutes" number="">6.3 Strukturanalytik</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Elektrische Energiespeicher und -umwandlung</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="themenfelder" number="">Chemische Charakterisierung und Spurenanalytik</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="literaturgattung" number="">Graue Literatur</collection>
    <collection role="institutes" number="">P.0 Präsident und andere</collection>
    <collection role="unnumberedseries" number="">Preprints der BAM</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/65094/Manuscript_LIF_final_preprint.pdf</file>
  </doc>
</export-example>