<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>59877</id>
    <completedYear/>
    <publishedYear>2024</publishedYear>
    <thesisYearAccepted/>
    <language>deu</language>
    <pageFirst>1</pageFirst>
    <pageLast>66</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>report</type>
    <publisherName>Deutsche Gesetzliche Unfallversicherung (DGUV)</publisherName>
    <publisherPlace>Berlin</publisherPlace>
    <creatingCorporation>Bundesanstalt für Materialforschung und -prüfung (BAM)</creatingCorporation>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="deu">Sicherheitstechnische Bewertung thermischer Betriebsbelastung auf sicherheitskritische Ausrüstung am Beispiel von Composite-Atemluftflaschen und Lithiumbatterien</title>
    <abstract language="deu">Ziel des Vorhabens war es, den Einfluss der realen Temperaturbelastung auf Atemschutzflaschen und Lithiumbatterien in Funkgeräten (FG) im Löscheinsatz von Rettungskräften zu ermitteln und deren Auswirkung auf die Alterung und Lebensdauer sowie die potenziellen Gesundheitsgefahren bei deren Nutzung besser beurteilen zu können und Handlungshilfen abzuleiten.&#13;
&#13;
Im Rahmen dieses Vorhabens wurden zum einen unterschiedlich thermisch gealterte Composite-Atemluftflaschen systematisch hinsichtlich ihrer Restfestigkeiten untersucht. Zum anderen wurden Lithiumbatterien aus FG hinsichtlich der Einwirkung von kritischen Temperaturen untersucht, ab denen es zu einem thermischen Durchgehen der Batterien kommen kann. Für diese beiden wichtigen Komponenten, Lithiumbatterien und Composite-Atemluftflaschen, wurden kritische Temperatur-Zeit-Profile ermittelt, die Auswirkungen durch geeignete Methodiken untersucht und die sich ergebenden Gefährdungen für den Träger bewertet.&#13;
&#13;
Als Methodische Vorgehensweise wurden durch Realversuche die tatsächlichen und zuvor durch Literatur-recherche ermittelten Temperaturprofile verifiziert und auf deren Grundlage die Laborbelastungen abgeleitet. Um den Eigenschaften der aus Faserverbundwerkstoffen hergestellten Composite-Atemluftflaschen Rechnung zu tragen, wurden an zwei repräsentativen Baumustern unterschiedlicher Hersteller Stichprobengruppen unterschiedlicher thermischer Belastung ausgesetzt und hinsichtlich ihrer verbleibenden Restfestigkeitsabnahme geprüft und mit thermisch unbelasteten Baumustern verglichen. Neben den statischen Berstversuchen wurden auch kombinierte Alterungs- und Restfestigkeitsuntersuchungen an zyklisch belasteten Behältern durchgeführt.&#13;
&#13;
Die FG wurden thermisch sowohl statischen als auch zyklischen Belastungen ausgesetzt und mit Kapazitätsmessungen begleitet. Die statischen Versuche dienten dem Zweck, die maximale thermische Belastbarkeit der Akkus zu ermitteln, bei der noch kein Versagen auftritt. Bei den zyklischen Versuchen wurde der Temperaturverlauf bei Löscheinsätzen so nah wie möglich im Labor nachgestellt. Hierbei wurden die Akkus wiederholt einem Belastungsprofil mit konstanter Temperatur ausgesetzt und nach einigen Intervallen die Restkapazitäten am Akku gemessen und so die Degradation bestimmt.&#13;
&#13;
Als Fazit der im Rahmen dieses Vorhabens durchgeführten Untersuchungen an zwei repräsentativen Baumustern von Atemschutzflaschen kann gefolgert werden, dass die thermischen Belastungen abhängig vom Baumuster einen z.T. deutlichen Einfluss auf die Restfestigkeiten der Atemschutzflaschen haben. Höhere thermische Exposition ist, zumindest an den untersuchten Atemschutzflaschen, deutlich zu erkennen und die Flaschen können durch die zuständigen Gerätewarte leicht ausgesondert und ersetzt werden. Die thermischen Belastungen, wie sie im Rettungseinsatz auftreten, waren für die untersuchten Atemschutzflaschen und die Rettungskräfte nicht kritisch sind. Die langjährige Erfahrung etablierter Hersteller dürfte hier aber nicht ohne Einfluss sein. Es ist somit kein Grund erkennbar, von der Verwendung der leichteren Typ 4 Atemschutzflaschen abzuraten, wenn Atemschutzflaschen, die visuell erkennbare thermische Einwirkungen (Farbänderungen, Materialschmelzungen o.ä.) aufweisen, unmittelbar ersetzt werden.&#13;
&#13;
Die Ergebnisse an den FG zeigen, dass trotz hoher Temperaturen keine Selbstentzündung der Lithiumbatterien ausgelöst wird. Der Kapazitätsverlust der Batterien infolge der Belastung führt ebenfalls nicht zu einem Funktionsausfall. Es konnte gezeigt werden, dass die Kapazitätsbestimmung als zuverlässiges und geeignetes Kriterium für die Sicherheitsbewertung der Akkus herangezogen werden kann, wenn die Kapazitätsmessung bei gleichbleibenden Bedingungen (gleiche Raumtemperaturen, gleiche Messgeräte, etc.) stattfindet. Es wird empfohlen, die Akkus ab einer Restkapazität von unter 80% zu tauschen. Als schnelle und sehr einfache Überprüfung kann eine Sichtprüfung an den FG stattfinden. Die im Projekt verwendeten FG zeigten eine Verformung der Kunststoffhülle bei zu hohen Belastungen.</abstract>
    <abstract language="eng">The aim of the project was to determine the influence of the real temperature load on breathing apparatus cylinders and Lithium batteries in radio devices in firefighting operations by rescue services and to be able to better assess their effect on ageing and service life time as well as the potential health hazards and to derive guidelines for action.&#13;
&#13;
As part of this project, composite breathing air cylinders that had undergone different thermal ageing processes were systematically analysed with regard to their residual strength. as a second use case, lithium batteries used in radio devices were analysed with regard to the effect of critical temperatures above which thermal runaway of the batteries can occur. Critical temperature-time profiles were determined for these two important components, lithium batteries and composite breathing air cylinders, the effects for the user were analysed using suitable methods and the resulting hazards for the wearer were assessed.&#13;
&#13;
As a methodical approach, the actual temperature profiles previously determined by literature research were first verified in real tests and the laboratory loads were derived on this basis. In order to take into account the properties of composite breathing air cylinders made of fibre composites, sample groups were subjected to different thermal loads and examined with regard to their residual strength reduction and in comparison to thermally unloaded samples from two representative samples from different manufacturers. In addition to the static burst tests, combined ageing and residual strength tests were also carried out on cyclic loaded cylinders.&#13;
&#13;
The radio devices were subjected to both static and cyclic thermal loads with accompanying capacity measurements. The purpose of the static tests was to determine the maximum thermal load capacity of the batteries at which no failure occurs. In the cyclic tests, practical conditions were simulated as closely as possible in the laboratory. For this purpose, the batteries were repeatedly subjected to a load profile at a constant temperature and the residual capacity of the battery was measured after several intervals to determine the degradation.&#13;
&#13;
As a conclusion of the tests carried out on two representative types of breathing apparatus cylinders as part of this project, it can be concluded that the thermal loads have a sometimes significant influence on the residual strength of the breathing apparatus cylinders, depending on the type. Higher thermal exposure is clearly recognizable, at least on the breathing apparatus cylinders tested, and the cylinders can be easily remove and replaced by the responsible equipment maintainers. The thermal loads that occur during rescue operations were not critical for the tested breathing protection cylinders and the rescue teams. However, the many years of experience of established manufacturers should not be without influence here. There is therefore no reason to advise against the use of the lighter Type 4 breathing protection breathing apparatus cylinders if cylinders with visually recognizable thermal effects (color changes, material melting, etc.) are replaced immediately.&#13;
&#13;
The results on the radio devices showed that determination of the capacity can serve as a suitable criterion for the safety assessment for the batteries. The loss of capacity of the batteries as a result of the load also does not lead to a functional failure. The capacity determination can be used as a reliable and suitable criterion for the safety assessment of the batteries if the capacity measurement is carried out under constant conditions (same room temperatures, same measuring devices, etc.). It is recommended to replace the batteries when the remaining capacity is below 80%. A visual inspection of the radio devices can be carried out as a quick and very simple check. The radio devices used in the project showed deformation of the plastic casing when subjected to excessive loads.</abstract>
    <identifier type="url">https://www.dguv.de/ifa/forschung/projektverzeichnis/ff-fp0462.jsp</identifier>
    <note>Abschlussbericht zum Vorhaben mit der Projekt-Nr. FF-FP 0462 (CoLiBri), Laufzeit 01.03.2021–29.02.2024, Bericht vom 15.04.2024</note>
    <enrichment key="opus.source">publish</enrichment>
    <author>Eric Duffner</author>
    <author>Chalid el Dsoki</author>
    <author>Sebastian John</author>
    <author>Anita Schmidt</author>
    <author>Georg W. Mair</author>
    <author>Derek Loechner</author>
    <author>Björn Drousch</author>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Composite</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Atemluftflaschen</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Litiumbatterien</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Funkgeräte</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Thermische Belastung</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Rettungskräfte</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Feuerwehr</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>PSA</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>DGUV</value>
    </subject>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="institutes" number="">3 Gefahrgutumschließungen; Energiespeicher</collection>
    <collection role="institutes" number="">3.1 Sicherheit von Gefahrgutverpackungen und Batterien</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Elektrische Energiespeicher und -umwandlung</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Graue Literatur</collection>
    <collection role="institutes" number="">3.5 Sicherheit von Gasspeichern und Gefahrguttanks</collection>
    <collection role="themenfelder" number="">Wasserstoff</collection>
  </doc>
  <doc>
    <id>64264</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>7</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume>36</volume>
    <type>article</type>
    <publisherName>Elsevier Ltd.</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">High-speed synchrotron radiography of nail penetration-induced thermal runaway: Understanding the explosive behavior of commercial sodium-ion batteries with NFM cathode</title>
    <abstract language="eng">The dynamics of mechanically initiated thermal runaway (TR) events in  cylindrical 18650 cells with NFM (Na(Ni1/3Fe1/3Mn1/3)O2), LFP (LiFePO4), and NMC532 (LiNi1/2Mn1/3Co1/5O2) cathode chemistries were investigated using high-speed synchrotron X-ray imaging. Structural similarity index measures (SSIM) were employed to identify and track rapid structural changes. In this manner, thermal decompositions and internal propagation dynamics, influencing the safety mechanisms of the cells, were studied. This lead to two major findings: (I) Among NFM, LFP, and NMC532 cells, the TR-characteristics differ significantly in temperature and internal propagation speed. Internal safety mechanisms appear, however, visually similar. Among all samples, LFP cells exhibit higher safety performance concerning the initiation of TR by nail penetration and the progression of TR. (II) The NFM cells used in this study displayed an almost explosive TR. This finding appears counterintuitive on a first glance, since sodium-ion batteries are usually considered safe. High-speed imaging revealed that the explosive TR is not necessarily caused by the thermochemical decomposition reactions, but rather by a failure of the venting mechanism. This results in a significant pressure buildup within the cell upon TR initiation and eventually a severely violent TR. These results underline that battery safety depends on many factors and not solely on optimized cell chemistries or materials.</abstract>
    <parentTitle language="eng">Journal of Power Sources Advances</parentTitle>
    <identifier type="issn">2666-2485</identifier>
    <identifier type="doi">10.1016/j.powera.2025.100188</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-642649</identifier>
    <enrichment key="opus_doi_flag">true</enrichment>
    <enrichment key="local_crossrefDocumentType">journal-article</enrichment>
    <enrichment key="local_crossrefLicence">https://www.elsevier.com/tdm/userlicense/1.0/</enrichment>
    <enrichment key="local_import_origin">crossref</enrichment>
    <enrichment key="local_doiImportPopulated">PersonAuthorFirstName_1,PersonAuthorLastName_1,PersonAuthorFirstName_2,PersonAuthorLastName_2,PersonAuthorFirstName_3,PersonAuthorLastName_3,PersonAuthorFirstName_4,PersonAuthorLastName_4,PersonAuthorFirstName_5,PersonAuthorLastName_5,PersonAuthorFirstName_6,PersonAuthorLastName_6,PersonAuthorFirstName_7,PersonAuthorLastName_7,PersonAuthorFirstName_8,PersonAuthorLastName_8,PersonAuthorIdentifierOrcid_8,PublisherName,TitleMain_1,Language,TitleParent_1,ArticleNumber,Volume,PublishedYear,IdentifierIssn,Enrichmentlocal_crossrefLicence</enrichment>
    <enrichment key="opus.source">doi-import</enrichment>
    <enrichment key="date_peer_review">20.10.2025</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Jonas Pfaff</author>
    <author>Sebastian Schopferer</author>
    <author>Henning Markötter</author>
    <author>Alexander Rack</author>
    <author>Giovanni Bruno</author>
    <author>Anita Schmidt</author>
    <author>Tim Tichter</author>
    <author>Nils Böttcher</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>High-speed X-ray radiography</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Synchrotron X-rays</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>18650</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>SIB</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Na-NFM</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Structure similarity index measure</value>
    </subject>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="institutes" number="">3 Gefahrgutumschließungen; Energiespeicher</collection>
    <collection role="institutes" number="">3.1 Sicherheit von Gefahrgutverpackungen und Batterien</collection>
    <collection role="institutes" number="">8 Zerstörungsfreie Prüfung</collection>
    <collection role="institutes" number="">8.5 Röntgenbildgebung</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Elektrische Energiespeicher und -umwandlung</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/64264/High-speed synchrotron radiography of nail penetration-induced thermal runaway.pdf</file>
  </doc>
  <doc>
    <id>64377</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>11</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>article</type>
    <publisherName>Royal Society of Chemistry (RSC)</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Exploring Age-Induced Lithium Isotope Fractionation in Lithium-Ion Batteries using Microwave-Induced Cold Nitrogen Plasma Mass Spectrometry</title>
    <abstract language="eng">This study explores Microwave-Inductively Coupled Atmospheric-pressure Plasma Mass Spectrometry (MICAP-MS) as a cost-effective alternative to Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS) for analyzing lithium isotopic composition in lithium-ion batteries (LIBs). We investigate the performance of MICAP-MS in measuring Li isotope ratios in new and aged commercial lithium cobalt oxide (LCO) batteries. Our results show that MICAP-MS, operating under cold plasma conditions at 800 W with an 8 mm torch position, achieves results metrologically compatible with MC-ICP-MS, with a precision ranging from 0.6‰ to 3.4‰ for δ7Li values. MICAP-MS benefits from a dielectric resonator for uniform plasma, better ion velocity control, and higher energy efficiency. Optimal settings were identified with dwell times of 10 ms for 6Li and 1 ms for 7Li. The study of LIBs revealed that 6Li migrates towards the anode over multiple charge–discharge cycles, causing 7Li to accumulate in the cathode, a fractionation effect that becomes more pronounced with prolonged cycling. MICAP-MS provides a cost-effective, precise alternative to MC-ICP-MS, with lower operational costs and enhanced portability, advancing the study of isotopic fractionation and aging in lithium-ion batteries.</abstract>
    <parentTitle language="eng">Journal of Analytical Atomic Spectrometry</parentTitle>
    <identifier type="issn">0267-9477</identifier>
    <identifier type="doi">10.1039/d4ja00324a</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-643777</identifier>
    <enrichment key="opus_doi_flag">true</enrichment>
    <enrichment key="local_crossrefDocumentType">journal-article</enrichment>
    <enrichment key="local_crossrefLicence">http://creativecommons.org/licenses/by/3.0/</enrichment>
    <enrichment key="local_import_origin">crossref</enrichment>
    <enrichment key="local_doiImportPopulated">PersonAuthorFirstName_1,PersonAuthorLastName_1,PersonAuthorFirstName_2,PersonAuthorLastName_2,PersonAuthorFirstName_3,PersonAuthorLastName_3,PersonAuthorFirstName_4,PersonAuthorLastName_4,PersonAuthorFirstName_5,PersonAuthorLastName_5,PersonAuthorFirstName_6,PersonAuthorLastName_6,PersonAuthorFirstName_7,PersonAuthorLastName_7,PersonAuthorFirstName_8,PersonAuthorLastName_8,PersonAuthorFirstName_9,PersonAuthorLastName_9,PersonAuthorFirstName_10,PersonAuthorLastName_10,PublisherName,TitleMain_1,Language,TitleAbstract_1,TitleParent_1,PublishedYear,IdentifierIssn,Enrichmentlocal_crossrefLicence</enrichment>
    <enrichment key="opus.source">doi-import</enrichment>
    <enrichment key="date_peer_review">27.10.2025</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Dalia Morcillo</author>
    <author>Alexander Winckelmann</author>
    <author>Marcus Oelze</author>
    <author>Robert Leonhardt</author>
    <author>Anita Schmidt</author>
    <author>Silke Richter</author>
    <author>Sebastian Recknagel</author>
    <author>Jochen Vogl</author>
    <author>Ulrich Panne</author>
    <author>Carlos Enrique Abad Andrade</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>MICAP-MS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Lithium</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Battery aging</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Lithium isotopes</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Nitrogen plasma</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Isotope fractionation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>lithium cobalt oxide</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LCO</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="institutes" number="">P Präsident</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.1 Anorganische Spurenanalytik</collection>
    <collection role="institutes" number="">1.6 Anorganische Referenzmaterialien und Gasanalytik</collection>
    <collection role="institutes" number="">3 Gefahrgutumschließungen; Energiespeicher</collection>
    <collection role="institutes" number="">3.1 Sicherheit von Gefahrgutverpackungen und Batterien</collection>
    <collection role="institutes" number="">S Qualitätsinfrastruktur</collection>
    <collection role="institutes" number="">S.1 Qualität im Prüfwesen</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Elektrische Energiespeicher und -umwandlung</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="themenfelder" number="">Chemische Charakterisierung und Spurenanalytik</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <collection role="institutes" number="">P.0 Präsident und andere</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/64377/Morcillo_et_al_2025.pdf</file>
    <file>https://opus4.kobv.de/opus4-bam/files/64377/Supporting_information_Morcillo_et_al_2025.pdf</file>
  </doc>
</export-example>