    <title language="eng">Novel sensor for long-term monitoring of ammonia in gas phase</title>
    <abstract language="eng">Because ammonia and its reaction products can cause considerable damage to human health and ecosystems, there is a need for reliably operating and reversibly interacting sensor materials to monitor traces of gaseous ammonia in ambient air, which at best can be used on-site for in-the-field measurements. Herein, the development of a sensor material for gaseous ammonia in the lower ppm to ppb range using optical fluorescence as transduction mechanism is presented. A fluorescent dye, which shows reversible fluorescence enhancement in the presence of ammonia is incorporated into a polymer matrix, the latter to ensure the accumulation of ammonia. The sensor material is integrated into a prototype of a miniaturized sensor device, facilitating long-term operation. To calibrate the optical sensor system a gas standard generator, producing standard gas mixtures, is used, leading to a sensitivity down to lower ppm concentrations of ammonia.</abstract>
    <parentTitle language="eng">13. Dresdner Sensor-Symposium 2017</parentTitle>
    <identifier type="doi">10.5162/13dss2017/P4.02</identifier>
    <enrichment key="eventName">13. Dresdner Sensor-Symposium 2017</enrichment>
    <enrichment key="eventPlace">Dresden, Germany</enrichment>
    <enrichment key="eventStart">04.12.2017</enrichment>
    <enrichment key="eventEnd">06.12.2017</enrichment>
    <author>Kornelia Gawlitza</author>
    <author>Carlo Tiebe</author>
    <author>Ulrich Banach</author>
    <author>Reinhard Noske</author>
    <author>Matthias Bartholmai</author>
    <author>Knut Rurack</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Ammonia gas sensor</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Fluorescence</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Air quality monitoring</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Standard gas generator</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Miniaturized sensor device</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="ddc" number="628">Sanitär- und Kommunaltechnik; Umwelttechnik</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Graue Literatur</collection>
  </doc>
  <doc>
    <id>65027</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>16</pageLast>
    <pageNumber/>
    <edition/>
    <issue>1</issue>
    <volume>16</volume>
    <type>article</type>
    <publisherName>Springer Science and Business Media LLC</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Ratiometric detection of perfluoroalkyl carboxylic acids using dual fluorescent nanoparticles and a miniaturised microfluidic platform</title>
    <abstract language="eng">The widespread contamination of soil and water with perfluoroalkyl substances (PFAS) has caused considerable societal and scientific concern. Legislative measures and an increased need for remediation require effective on-site analytical methods for PFAS management. Here we report on the development of a green-fluorescent guanidine-BODIPY indicator monomer incorporated into a molecularly imprinted polymer (MIP) for the selective detection of perfluorooctanoic acid (PFOA). Complexation of PFOA by the indicator, which is mediated by concerted protonation-induced ion pairing-assisted hydrogen bonding, significantly enhances fluorescence in polar organic solvents. The MIP forms as a thin layer on silica nanoparticles doped with tris(bipyridine)ruthenium(II) chloride, which provides an orange emission signal as internal reference, resulting in low measurement uncertainties. Using a liquid-liquid extraction protocol, this assay enables the direct detection of PFOA in environmental water samples and achieves a detection limit of 0.11 µM. Integration into an opto-microfluidic system enables a compact and user-friendly system for detecting PFOA in less than 15 minutes.</abstract>
    <parentTitle language="eng">Nature Communications</parentTitle>
    <identifier type="issn">2041-1723</identifier>
    <identifier type="doi">10.1038/s41467-025-66872-9</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-650270</identifier>
    <enrichment key="opus_doi_flag">true</enrichment>
    <enrichment key="local_crossrefDocumentType">journal-article</enrichment>
    <enrichment key="local_crossrefLicence">https://creativecommons.org/licenses/by/4.0</enrichment>
    <enrichment key="local_import_origin">crossref</enrichment>
    <enrichment key="local_doiImportPopulated">PersonAuthorFirstName_1,PersonAuthorLastName_1,PersonAuthorIdentifierOrcid_1,PersonAuthorFirstName_2,PersonAuthorLastName_2,PersonAuthorIdentifierOrcid_2,PersonAuthorFirstName_3,PersonAuthorLastName_3,PersonAuthorFirstName_4,PersonAuthorLastName_4,PersonAuthorIdentifierOrcid_4,PersonAuthorFirstName_5,PersonAuthorLastName_5,PersonAuthorIdentifierOrcid_5,PersonAuthorFirstName_6,PersonAuthorLastName_6,PersonAuthorIdentifierOrcid_6,PublisherName,TitleMain_1,Language,TitleAbstract_1,TitleParent_1,ArticleNumber,Issue,Volume,PublishedYear,IdentifierIssn,Enrichmentlocal_crossrefLicence</enrichment>
    <enrichment key="opus.source">doi-import</enrichment>
    <enrichment key="date_peer_review">15.12.2025</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Yijuan Sun</author>
    <author>Víctor Pérez-Padilla</author>
    <author>Virginia Valderrey</author>
    <author>Jérémy Bell</author>
    <author>Kornelia Gawlitza</author>
    <author>Knut Rurack</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>PFAS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Molecular imprinting</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Microfluidics</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Fluorescence</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Onsite assay</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="ddc" number="620">Ingenieurwissenschaften und zugeordnete Tätigkeiten</collection>
    <collection role="ddc" number="628">Sanitär- und Kommunaltechnik; Umwelttechnik</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.9 Chemische und optische Sensorik</collection>
    <collection role="themenfelder" number="">Umwelt</collection>
    <collection role="themenfelder" number="">Material</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="themenfelder" number="">Chemische Charakterisierung und Spurenanalytik</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <collection role="themenfelder" number="">Advanced Materials</collection>
    <collection role="themenfelder" number="">Sensorik</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/65027/NatCommun_2025_16_10869.pdf</file>
  </doc>
  <doc>
    <id>52576</id>
    <completedYear/>
    <publishedYear>2021</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>133</pageFirst>
    <pageLast>134</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Semi-automatic Measurement Device for Long-Term Monitoring of Ammonia in Gas Phase</title>
    <abstract language="eng">In the present paper the development of a semi-automated device for long-term monitoring of gaseous ammonia is described. A sensor material was produced that changes its optical properties in the pres-ence of low concentrations of ammonia in air. The implementation into an electronic device enables precise, simple, economic and fast monitoring of low concentrations of harmful gases, like ammonia, and hence can help to improve the climate monitoring in livestock housing, barns or stables.</abstract>
    <parentTitle language="eng">SMSI 2021 Proceedings</parentTitle>
    <enrichment key="eventName">SMSI 2021</enrichment>
    <enrichment key="eventPlace">Online meeting</enrichment>
    <enrichment key="eventStart">03.05.2021</enrichment>
    <enrichment key="eventEnd">06.05.2021</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>Kornelia Gawlitza</author>
    <author>Sergej Johann</author>
    <author>Maria Mansurova</author>
    <author>Harald Kohlhoff</author>
    <author>Carlo Tiebe</author>
    <author>Jérémy Bell</author>
    <author>Matthias Bartholmai</author>
    <author>Knut Rurack</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Spectroscopy</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Embedded sensor</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Environment</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Air quality</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="ddc" number="628">Sanitär- und Kommunaltechnik; Umwelttechnik</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.9 Chemische und optische Sensorik</collection>
    <collection role="institutes" number="">8 Zerstörungsfreie Prüfung</collection>
    <collection role="institutes" number="">8.1 Sensorik, mess- und prüftechnische Verfahren</collection>
    <collection role="themenfelder" number="">Umwelt</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Graue Literatur</collection>
    <collection role="themenfelder" number="">Sensorik</collection>
  </doc>
  <doc>
    <id>50867</id>
    <completedYear/>
    <publishedYear>2020</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>133</pageFirst>
    <pageLast>134</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Semi-automatic Measurement Device for Long-Term Monitoring of Ammonia in Gas Phase</title>
    <abstract language="eng">The present paper describes the development of a sensor material that changes its fluorescence in the presence of gaseous ammonia in a relevant concentration range. The implementation into a semi-automatic gas measurement device enables low-cost, precise, simple and fast monitoring of low con-centrations of harmful gases, like ammonia, and hence can help to improve the climate monitoring in livestock housing, barns or stables.</abstract>
    <parentTitle language="eng">SMSI 2020 Proceedings</parentTitle>
    <identifier type="doi">10.5162/SMSI2020/B5.4</identifier>
    <enrichment key="eventName">SMSI 2020</enrichment>
    <enrichment key="eventPlace">Meeting was canceled</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>Kornelia Gawlitza</author>
    <author>Sergej Johann</author>
    <author>M. Mansurova</author>
    <author>Harald Kohlhoff</author>
    <author>Carlo Tiebe</author>
    <author>Jérémy Bell</author>
    <author>Matthias Bartholmai</author>
    <author>Knut Rurack</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Spectroscopy</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Emmbedded sensor</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Environment</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Air quality</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.9 Chemische und optische Sensorik</collection>
    <collection role="institutes" number="">8 Zerstörungsfreie Prüfung</collection>
    <collection role="institutes" number="">8.1 Sensorik, mess- und prüftechnische Verfahren</collection>
    <collection role="themenfelder" number="">Umwelt</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="themenfelder" number="">Sensorik</collection>
  </doc>
  <doc>
    <id>51705</id>
    <completedYear/>
    <publishedYear>2020</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>4950</pageFirst>
    <pageLast>4961</pageLast>
    <pageNumber/>
    <edition/>
    <issue>22</issue>
    <volume>8</volume>
    <type>article</type>
    <publisherName>Royal Society of Chemistry</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Optimization of analytical assay performance of antibody-gated indicator-releasing mesoporous silica particles</title>
    <abstract language="eng">Antibody-gated indicator delivery (gAID) systems based on mesoporous silica nano- and microparticle scaffolds are a promising class of materials for the sensitive chemical detection of small-molecule analytes in simple test formats such as lateral flow assays (LFAs) or microfluidic chips. Their architecture is reminiscent of drug delivery systems, only that reporter molecules instead of drugs are stored in the voids of a porous host particle. In addition, the pores are closed with macromolecular “caps” through a tailored “gatekeeping” recognition chemistry so that the caps are opened when an analyte has reacted with a “gatekeeper”. The subsequent uncapping leads to a release of a large number of indicator molecules, endowing the system with signal amplification features. Particular benefits of such systems are their modularity and adaptability. With the example of the immunochemical detection of type-I pyrethroids by fluorescent dye-releasing gAID systems, the influence of several tuning modes on the optimisation of such hybrid sensory materials is introduced here. In particular, different mesoporous silica supports (from nano- and microparticles to platelets and short fibres), different functionalisation routes and different loading sequences were assessed. The materials’ performances were evaluated by studying their temporal response behaviour and detection sensitivity, including the tightness of pore closure (through the amount of blank release in the absence of analyte) and the release kinetics. Our results indicate that the better the paratope-accommodating Fab region of the antibody “cap” fits into the host material's pore opening, the better the closing/opening mechanism can be controlled. Because such materials are well-suited for LFAs, performance assessment included a test-strip format besides conventional assays in suspension. In combination with dyes as indicators and smartphones for read-out, simple analytical tests for use by untrained personnel directly at a point-of-need such as an aeroplane cabin can be devised, allowing for sensitivities down to the μg kg−1 range in &lt;5 min with case-required selectivities.</abstract>
    <parentTitle language="eng">Journal of Materials Chemistry B</parentTitle>
    <identifier type="doi">10.1039/d0tb00371a</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-517053</identifier>
    <enrichment key="date_peer_review">08.06.2020</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Elena Costa</author>
    <author>Estela Climent Terol</author>
    <author>Kornelia Gawlitza</author>
    <author>Wei Wan</author>
    <author>Michael G. Weller</author>
    <author>Knut Rurack</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Antibody-gated indicator delivery</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Lateral flow assay</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>SBA-15</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>SBA-16</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Type-I pyrethroids</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Phenothrin</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Permethrin</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Etofenprox</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Amplification</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Biosensors</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Immunoassays</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Mesoporous particles</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Optical detection</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="ddc" number="620">Ingenieurwissenschaften und zugeordnete Tätigkeiten</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.5 Proteinanalytik</collection>
    <collection role="institutes" number="">1.9 Chemische und optische Sensorik</collection>
    <collection role="themenfelder" number="">Umwelt</collection>
    <collection role="themenfelder" number="">Material</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="themenfelder" number="">Chemische Charakterisierung und Spurenanalytik</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <collection role="themenfelder" number="">Advanced Materials</collection>
    <collection role="themenfelder" number="">Sensorik</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/51705/Costa-2020-JMaterChemB-Supplement.pdf</file>
    <file>https://opus4.kobv.de/opus4-bam/files/51705/Costa-2020-JMaterChemB.pdf</file>
  </doc>
  <doc>
    <id>65733</id>
    <completedYear/>
    <publishedYear>2026</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>13</pageLast>
    <pageNumber/>
    <edition/>
    <issue>3</issue>
    <volume>5</volume>
    <type>article</type>
    <publisherName>Wiley-VCH</publisherName>
    <publisherPlace>Weinheim</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Detection of Perfluoroalkylic Acids From Water Using a Guanidine-Based Fluorescent Probe and Microfluidic Droplet Extraction</title>
    <abstract language="eng">Perfluoroalkylic acids (PFAAs), a subclass of per- and polyfluoroalkyl substances (PFAS), are stable, widely used industrial compounds posing environmental concerns due to their persistence and toxicity. Regulatory actions and remediation strategies necessitate effective onsite analytical methods for PFAS management. We developed an optical sensing system using a fluorescent probe with a benzoxadiazole core and guanidine receptor in a droplet-based microfluidic assay to detect PFAAs in water samples with low detection limits. The PFAAs binding enhances the probe's fluorescence in organic media through protonation-mediated hydrogen bond-assisted ion pairing, exploiting two complementary supramolecular forces. Direct detection employs a liquid-liquid extraction protocol in the microfluidic device, achieving detection limits for PFOA and PFOS down to ≥0.5 µm, with a dynamic range up to 200 µm for sample volumes &lt;100 µL. HCl/KCl buffering facilitates analyte desalting and phase transfer for quantitation from surface water. Additionally, we developed a method involving a thin polymer layer of the probe and a crosslinker on submicron silica particles for direct detection of PFAAs in water. Our approaches provide sensitive, direct recognition and indication of PFAAs, advancing the field beyond indirect sensing and offering improved background suppression, rapid assay times, and a modular design for targeting other PFAS subclasses.</abstract>
    <parentTitle language="eng">Advanced Sensor Research</parentTitle>
    <identifier type="doi">10.1002/adsr.70145</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-657330</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Víctor Pérez-Padilla</author>
    <author>Samual C. Burnage</author>
    <author>Philipp Wittwer</author>
    <author>Virginia Valderrey</author>
    <author>Jérémy Bell</author>
    <author>Kornelia Gawlitza</author>
    <author>Knut Rurack</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>PFAS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Fluorescence</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Microfluidics</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Droplet Extraction</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="ddc" number="604">Spezielle Themen</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.9 Chemische und optische Sensorik</collection>
    <collection role="institutes" number="">4 Material und Umwelt</collection>
    <collection role="institutes" number="">4.4 Thermochemische Reststoffbehandlung und Wertstoffrückgewinnung</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="themenfelder" number="">Chemische Charakterisierung und Spurenanalytik</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <collection role="themenfelder" number="">Gefährliche Stoffe</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/65733/AdvSensRes_2026_5_e70145.pdf</file>
  </doc>
</export-example>