<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>52134</id>
    <completedYear/>
    <publishedYear>2021</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1225</pageFirst>
    <pageLast>1238</pageLast>
    <pageNumber/>
    <edition/>
    <issue>2</issue>
    <volume>14</volume>
    <type>article</type>
    <publisherName>Copernicus Publications</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Facility for production of ambient-like model aerosols (PALMA) inthe laboratory: application in the intercomparison of automated PMmonitors with the reference gravimetric method</title>
    <abstract language="eng">A new facility has been developed which allows for a  stable  and  reproducible  production  of  ambient-like model aerosols (PALMA) in the laboratory. The set-up consists of multiple aerosol generators, a custom-made flow tube homogeniser,  isokinetic  sampling  probes,  and  a  system  to control  aerosol  temperature  and  humidity.  Model  aerosols containing elemental carbon, secondary organic matter from the ozonolysis of α-pinene, inorganic salts such as ammonium sulfate and ammonium nitrate, mineral dust particles,and water were generated under different environmental conditions and at different number and mass concentrations. The aerosol physical and chemical properties were characterised with an array of experimental methods, including scanning mobility particle sizing, ion chromatography, total reflection X-ray fluorescence spectroscopy and thermo-optical analysis. The facility is very versatile and can find applications in the calibration and performance characterisation of aerosol instruments  monitoring  ambient  air.  In  this  study,  we  performed, as proof of concept, an intercomparison of three different commercial PM (particulate matter) monitors (TEOM1405, DustTrak DRX 8533 and Fidas Frog) with the gravimetric reference method under three simulated environmental  scenarios.  The  results  are  presented  and  compared  to previous field studies. We believe that the laboratory-based method for simulating ambient aerosols presented here could provide in the future a useful alternative to time-consuming and expensive field campaigns, which are often required for instrument certification and calibration.</abstract>
    <parentTitle language="eng">Atmospheric Measurement Techniques</parentTitle>
    <identifier type="doi">10.5194/amt-14-1225-2021</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-521342</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="date_peer_review">25.03.2021</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>S. Horender</author>
    <author>K. Auderset</author>
    <author>P. Quincey</author>
    <author>Stefan Seeger</author>
    <author>S. N. Skov</author>
    <author>K. Dierschel</author>
    <author>T. O.M. Smith</author>
    <author>K. Williams</author>
    <author>C. C. Aegerter</author>
    <author>D. M. Kalbermatter</author>
    <author>F. Gaie-Levrel</author>
    <author>K. Vasilatou</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Model aerosols</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Intercomparison</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>PM monitors</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Aerosol gravimetry</value>
    </subject>
    <collection role="ddc" number="628">Sanitär- und Kommunaltechnik; Umwelttechnik</collection>
    <collection role="institutes" number="">4 Material und Umwelt</collection>
    <collection role="institutes" number="">4.2 Material-Mikrobiom Wechselwirkungen</collection>
    <collection role="themenfelder" number="">Umwelt</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/52134/amt-14-1225-2021 Horender et.al.pdf</file>
  </doc>
  <doc>
    <id>42506</id>
    <completedYear/>
    <publishedYear>2017</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>146</pageFirst>
    <pageLast>164</pageLast>
    <pageNumber/>
    <edition/>
    <issue>2</issue>
    <volume>52</volume>
    <type>article</type>
    <publisherName>Tailor &amp; Francis</publisherName>
    <publisherPlace>USA</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Mobility particle size spectrometers: Calibration procedures and measurement uncertainties</title>
    <abstract language="eng">Mobility particle size spectrometers (MPSS) belong to the essential instruments in aerosol science that determine the particle number size distribution (PNSD)in the submicrometer size range. Following calibration procedures and target uncertainties against standards and reference instruments are suggested for a complete MPSS quality assurance program: a) calibration of the CPC counting efficiency curve (within 5% for the plateau counting efficiency; within 1 nm for the 50% detection efficiency diameter), b) sizing calibration of the MPSS, using a certified polystyrene latex (PSL) particle size standard at 203 nm (within 3%), c) intercomparison of the PNSD of the MPSS (within 10% and 20% of the dN/dlogDP concentration for the particle size range 20 – 200 nm and 200 to 800 nm, respectively), and d) intercomparison of the integral PNC of the MPSS (within 10%). Furthermore, following measurement uncertainties have been investigated: a) PSL particle size standards in the range from 100-500nm match within 1% after sizing calibration at 203 nm. b) Bipolar diffusion chargers based on the radioactive nuclides Kr85, Am241 and Ni63 and a new ionizer based on corona discharge follow the recommended bipolar charge distribution, while soft X-ray-based charges may alter faster than expected. c) The use of a positive high voltage supply show a 10% better performance than a negative one. d) The intercomparison of the integral PNC of an MPSS against the total number concentration is still within the target uncertainty at an ambient pressure of approximately 500 hPa.</abstract>
    <parentTitle language="eng">Aerosol Science and Technology</parentTitle>
    <identifier type="doi">10.1080/02786826.2017.1387229</identifier>
    <identifier type="issn">1521-7388</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-425060</identifier>
    <enrichment key="date_peer_review">05.04.2018</enrichment>
    <licence>Creative Commons - Namensnennung - Nicht kommerziell 3.0</licence>
    <author>A. Wiedensohler</author>
    <author>A. Wiesner</author>
    <author>K. Weinhold</author>
    <author>W. Birmili</author>
    <author>M. Herrmann</author>
    <author>M. Merkel</author>
    <author>T. Müller</author>
    <author>S. Pfeifer</author>
    <author>A. Schmidt</author>
    <author>T. Tuch</author>
    <author>F. Velarde</author>
    <author>P. Quincey</author>
    <author>Stefan Seeger</author>
    <author>A. Nowak</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Measurement uncertainties</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Mobility particle size spectrometer (MPPS)</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Condensation particle counter (CPC)</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Calibration</value>
    </subject>
    <collection role="ddc" number="628">Sanitär- und Kommunaltechnik; Umwelttechnik</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/42506/Wiedensohler et al AST 2017 Mobility Particle Size Spectrometers Calibration Procedures and Measurement Uncertainties.pdf</file>
  </doc>
</export-example>