<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>43527</id>
    <completedYear/>
    <publishedYear>2018</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>108</pageFirst>
    <pageLast>115</pageLast>
    <pageNumber/>
    <edition/>
    <issue>1</issue>
    <volume>41</volume>
    <type>article</type>
    <publisherName>Wiley-VCH</publisherName>
    <publisherPlace>Weinheim</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Chemical-free pest control by dielectric&#13;
heating with radio waves and microwaves:&#13;
Thermal effects</title>
    <abstract language="eng">Thermal pest control with hot air is widely accepted as an alternative to chemical methods. However, it requires relatively long treatment times owing to the low thermal conductivity of wood. Direct dielectric heating that applies radio waves or microwaves has the advantage of more homogeneous heating. However, Sound experimental data on this technique are currently rare. Therefore, the thermal treatment of wood-destroying insects with radio waves and microwaves was studied with two model pests, Anobium punctatum and Hylotrupes bajulus, and with Tenebrio molitor as a reference. The secure elimination of pests was achieved, and the corresponding treatment time was in the range of a few minutes. Temperature profiles were more homogeneous when applying radio waves.</abstract>
    <parentTitle language="eng">Chemical engineering and technology</parentTitle>
    <identifier type="doi">10.1002/ceat.201600712</identifier>
    <identifier type="issn">1521-4125</identifier>
    <identifier type="issn">0930-7516</identifier>
    <enrichment key="date_peer_review">04.01.2018</enrichment>
    <author>C. Hoyer</author>
    <author>C. Pfütze</author>
    <author>Rüdiger Plarre</author>
    <author>U. Trommler</author>
    <author>S. Steinbach</author>
    <author>Kerstin Klutzny</author>
    <author>F. Holzer</author>
    <author>C. Rabe</author>
    <author>B. Höhlig</author>
    <author>S. Schmidt</author>
    <author>U. Roland</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Dielectric heating</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Microwaves</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Pest control</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Radio waves</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Wood protection</value>
    </subject>
    <collection role="ddc" number="620">Ingenieurwissenschaften und zugeordnete Tätigkeiten</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
  </doc>
  <doc>
    <id>31301</id>
    <completedYear/>
    <publishedYear>2014</publishedYear>
    <thesisYearAccepted/>
    <language>deu</language>
    <pageFirst>1187</pageFirst>
    <pageLast>1197</pageLast>
    <pageNumber/>
    <edition/>
    <issue>8</issue>
    <volume>86</volume>
    <type>article</type>
    <publisherName>Wiley-VCH Verl.</publisherName>
    <publisherPlace>Weinheim</publisherPlace>
    <creatingCorporation>Verein Deutscher Ingenieure</creatingCorporation>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="deu">Chemikalienfreie Bekämpfung von Holzschädlingen durch dielektrische Erwärmung mit Radiowellen und Mikrowellen</title>
    <abstract language="deu">Die thermische Bekämpfung von Holzschädlingen erfordert wegen der geringen Wärmeleitfähigkeit von Holz lange Behandlungszeiten und kann zur Rissbildung führen. Hier wurde die thermische Behandlung mittels Radio- und Mikrowellen untersucht. Die direkte, dielektrische Erwärmung hat den Vorteil einer größeren Homogenität der Aufheizung. Die mit Radiowellen erzielten Temperaturprofile waren homogener als die mit Mikrowellen realisierten. Untersuchungen zeigten, dass die Abtötung nicht auf die direkte Einwirkung von elektromagnetischen Feldern, sondern auf die Temperaturerhöhung zurückzuführen ist.</abstract>
    <abstract language="eng">Thermal pest control requires long treatment times due to the low thermal conductivity of wood and may lead to the formation of cracks. Here, the thermal treatment with radio waves as well as microwaves has been studied. The direct dielectric heating has the advantage of a good homogeneity. The obtained temperature profiles for radio waves were more homogeneous compared to microwaves. Detailed studies showed that elimination of pests was not related to the application of the electromagnetic field itself, but due to the temperature increase.</abstract>
    <parentTitle language="deu">Chemie - Ingenieur - Technik</parentTitle>
    <identifier type="old">34310</identifier>
    <identifier type="doi">10.1002/cite.201300091</identifier>
    <identifier type="issn">0009-286X</identifier>
    <identifier type="issn">1522-2640</identifier>
    <enrichment key="date_peer_review">04.09.2014</enrichment>
    <author>C. Hoyer</author>
    <author>C. Pfütze</author>
    <author>Rüdiger Plarre</author>
    <author>U. Trommler</author>
    <author>S. Steinbach</author>
    <author>Kerstin Klutzny</author>
    <author>F. Holzer</author>
    <author>C. Rabe</author>
    <author>B. Höhlig</author>
    <author>F.-D. Kopinke</author>
    <author>D. Schmidt</author>
    <author>U. Roland</author>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Dielektrische Erwärmung</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Holzschutz</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Mikrowellen</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Radiowellen</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Bekämpfung</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Insekten</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Dielectric heating</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Microwaves</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Pest control</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Radio waves</value>
    </subject>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
  </doc>
  <doc>
    <id>29721</id>
    <completedYear/>
    <publishedYear>2013</publishedYear>
    <thesisYearAccepted/>
    <language>deu</language>
    <pageFirst>107</pageFirst>
    <pageLast>115</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName>Fraunhofer IRB Verl.</publisherName>
    <publisherPlace/>
    <creatingCorporation>Sächsischer Holzschutzfachverband / EIPOS</creatingCorporation>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="deu">Thermische Bekämpfungsverfahren im Holzschutz mit elektromagnetischen Wellen</title>
    <abstract language="deu">Bekämpfungsverfahren gegen Organismen, die in Deutschland Bauholz wirtschaftlich bedeutend schädigen können, sind in der DIN 68800 Teil 4: 02/2012 „Holzschutz - Bekämpfungs- und Sanierungsmaßnahmen gegen Holz zerstörende Pilze und Insekten“ regeltechnisch zusammengefasst und gewichtet. Dabei wird je nach Verfahren und Schadorganismus zwischen Regelsanierung und Sondermaßnahmen unterschieden.&#13;
So wird z. B. bei den thermischen Maßnahmen im Sinne der Norm das sogenannte Heißluftverfahren gegen Insekten als Regelsanierung bezeichnet, wogegen es gegen Pilze nicht als solche ausgewiesen ist. Gleiches gilt für elektrophysikalische Verfahren sowohl gegen Pilze als auch gegen Insekten. Dies begründet sich dadurch, dass bei Erstellung der Norm Zweifel bezüglich weitgehender Allgemeingültigkeit und Praxisbewährtheit elektrophysikalischer Verfahren, wie sie zur Erwärmung des befallenen Holzes eingesetzt werden, bestanden. Somit erklärt sich auch, dass die Rahmenbedingungen einer erfolgreichen Bekämpfung mittels z. B. Mikrowellen denen des Heißluftverfahrens gleichgesetzt wurden, nämlich die vollständige Erwärmung des befallenen Holzbauteils auf eine Mindesttemperatur von 55° C für eine Dauer von mindestens 60 min. Die physikalisch-chemischen Vorteile der zeitgleichen Wärmegeneration im gesamten Holzkörper durch elektromagnetische Felder im Vergleich zum sukzessiven Wärmeeintrag durch Konduktion fanden keine Berücksichtigung.</abstract>
    <parentTitle language="deu">22. Tagung des Sächsischen Holzschutzverbandes - Modernes Bauen mit Holz</parentTitle>
    <identifier type="old">32653</identifier>
    <identifier type="isbn">978-3-8167-9132-4</identifier>
    <identifier type="isbn">978-3-8167-9133-1</identifier>
    <enrichment key="eventName">22. Tagung des Sächsischen Holzschutzverbandes - Modernes Bauen mit Holz</enrichment>
    <enrichment key="eventPlace">Dresden, Germany</enrichment>
    <enrichment key="eventStart">16.03.2013</enrichment>
    <enrichment key="eventEnd">16.03.2013</enrichment>
    <author>Rüdiger Plarre</author>
    <author>S. Steinbach</author>
    <author>U. Roland</author>
    <author>U. Trommler</author>
    <author>C. Hoyer</author>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Holzschutz</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Mikrowellentechnik</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Radiowellentechnik</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Normung</value>
    </subject>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
  </doc>
  <doc>
    <id>29269</id>
    <completedYear/>
    <publishedYear>2013</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>112</pageFirst>
    <pageLast>115</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Radio-frequency heating for pest control, decontamination and drying of timber and masonry</title>
    <abstract language="eng">A number of very relevant processes for protection and reconstruction of buildings can be supported by controlled heating: elimination of pests without using hazardous Chemicals, drying and decontamination of timber and many other building materials. For this purpose, radio-frequency (RF) dielectric heating is an advantageous Option because the materials and structures can be heated directly by energy absorption in the volume, homogeneously and, if required, relatively fast.&#13;
Compared to microwaves, the penetration depths are usually much larger and the flexibility with respect to different materials is wider. Namely, heating can also be realized for dry materials because the dielectric loss is as not closely related to the presence of water as for microwave applications.</abstract>
    <parentTitle language="eng">14th International conference on microwave and high frequency heating (Proceedings)</parentTitle>
    <identifier type="old">32180</identifier>
    <identifier type="isbn">978-0-85358-293-9</identifier>
    <enrichment key="eventName">14th International conference on microwave and high frequency heating</enrichment>
    <enrichment key="eventPlace">Nottingham, UK</enrichment>
    <enrichment key="eventStart">16.09.2013</enrichment>
    <enrichment key="eventEnd">19.09.2013</enrichment>
    <author>U. Roland</author>
    <author>U. Trommler</author>
    <author>C. Hoyer</author>
    <author>C. Pfütze</author>
    <author>Rüdiger Plarre</author>
    <author>C. Rabe</author>
    <author>B. Höhlig</author>
    <author>F. Holzer</author>
    <author>M. Kraus</author>
    <author>D. Schmidt</author>
    <author>F.-D. Kopinke</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Radio-frequency heating</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Drying</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Decontamination</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Pest control</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Timber</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Masonry</value>
    </subject>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
  </doc>
</export-example>