<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>1312</id>
    <completedYear/>
    <publishedYear>2002</publishedYear>
    <thesisYearAccepted/>
    <language>deu</language>
    <pageFirst>138</pageFirst>
    <pageLast>141</pageLast>
    <pageNumber/>
    <edition/>
    <issue>3</issue>
    <volume>69</volume>
    <type>article</type>
    <publisherName>Oldenbourg</publisherName>
    <publisherPlace>München</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="deu">Pyrometrische Temperaturmessung durch Flammenvorhänge hindurch (Pyrometric Temperature Measurement through Curtains of Flames)</title>
    <abstract language="deu">Die Oberflächentemperatur von Spaltrohren wurde im Temperaturbereich um 800°C durch Erdgas- bzw. Heizölflammen (Temperatur ca. 950°C) hindurch gemessen. Anhaltswerte wurden mit einer Vorrichtung zum Andrücken eines Thermoelementes gewonnen. Mit einem Teilstrahlungspyrometer und einem Flammenkorrektur-Verfahren konnte eine Messunsicherheit von ±15 K erreicht werden. &#13;
&#13;
The surface temperature of tubes (about 800°C) had to be measured through flames of natural gas or heating oil (temperature about 950°C). A good approximation was derived by pressing a thermocouple against the tubes. With a partial radiation pyrometer and a special flame correction the temperature of the tubes could be measured with an uncertainty of ±15 Kelvin.</abstract>
    <parentTitle language="deu">Technisches Messen</parentTitle>
    <identifier type="old">974</identifier>
    <identifier type="doi">10.1524/teme.2002.69.3.138</identifier>
    <identifier type="issn">0340-837X</identifier>
    <identifier type="issn">0178-2312</identifier>
    <identifier type="issn">0171-8096</identifier>
    <enrichment key="bibliotheksstandort">ZA 18</enrichment>
    <enrichment key="date_peer_review">07.03.2003</enrichment>
    <author>Norbert Mayer</author>
    <author>Wolfgang Vorwald</author>
    <author>Claus Amberg</author>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Berührungslose Temperaturmessung</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Infrarot-Thermometer</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Pyrometer-Messung</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Messung durch Flammen</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Flammenkorrektur</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Temperatur-Messgabel</value>
    </subject>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access")</collection>
  </doc>