<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>56928</id>
    <completedYear/>
    <publishedYear>2023</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>2</pageFirst>
    <pageLast>10</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Multi-sensory monitoring and ultrasound for quality assurance at underground sealing structures</title>
    <abstract language="eng">Within the safety concepts of underground disposal sites of nuclear waste, engineered barriers play an important role. As these sealing structures have high demands concerning integrity, we aim at advancing the available construction materials, monitoring, and inspection techniques within the project SealWasteSafe. A specifically developed alkali-activated material is compared to classical salt concrete. A comprehensive multi-sensory monitoring scheme is used at 150-340 l specimens to monitor setting and hardening of both materials. All sensors are demonstrated to resist the highly alkaline environments. Besides cabled and wireless temperature and humidity of the materials, strain variations using fibre optic sensors and acoustic emissions are recorded over periods of at least 28 days, partly for more than eight months. After hardening of the specimens, further nondestructive evaluations using ultrasonic echo and thermographic measurements are conducted.&#13;
Preliminary results proof the suitability of the tested sensors and clearly highlight differences between the tested materials. Particularly, the newly developed alkali-activated material shows lower acoustic emission activity indicating less cracking activity. Additionally, unique ultrasonic methods will enable better images of potential internal objects and cracks at in-situ sealing structures. A largescale ultrasonic system is optimised to reliably detect objects at a depth exceeding 9 m while still obtaining a good resolution. Modelling studies show the potential of further increasing the distance between individual transducer arrays. Additionally, a new ultrasonic borehole probe using phased arrays allowing for beam focussing is constructed and tested. Laboratory measurements at a halfcylindrical concrete specimen coincide well with the previous modelling. In total, the presented safe materials, detailed monitoring approaches and ultrasonic quality assurance methods will help to obtain safe sealing structures within salt as a host rock. The concepts can partly be transferred to sealing structures in alternative host rocks and will also be valuable for non-nuclear waste repositories.</abstract>
    <parentTitle language="eng">Proceedings of the International Conference on Non-destructive Evaluation of Concrete in Nuclear Applications</parentTitle>
    <enrichment key="eventName">NDE NucCon</enrichment>
    <enrichment key="eventPlace">Espoo, Finland</enrichment>
    <enrichment key="eventStart">25.01.2023</enrichment>
    <enrichment key="eventEnd">27.01.2023</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>Vera Lay</author>
    <author>Frank Mielentz</author>
    <author>Prathik Prabhakara</author>
    <author>Franziska Baensch</author>
    <author>Sergej Johann</author>
    <author>Detlef Hofmann</author>
    <author>Patrick Sturm</author>
    <author>Michael Stamm</author>
    <author>Ernst Niederleithinger</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>SealWasteSafe</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Engineered barriers</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Monitoring</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Embedded sensors</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Ultrasonic imaging</value>
    </subject>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="institutes" number="">7 Bauwerkssicherheit</collection>
    <collection role="institutes" number="">7.4 Baustofftechnologie</collection>
    <collection role="institutes" number="">8 Zerstörungsfreie Prüfung</collection>
    <collection role="institutes" number="">8.1 Sensorik, mess- und prüftechnische Verfahren</collection>
    <collection role="institutes" number="">8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen</collection>
    <collection role="institutes" number="">8.6 Faseroptische Sensorik</collection>
    <collection role="institutes" number="">8.3 Thermografische Verfahren</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Graue Literatur</collection>
    <collection role="themenfelder" number="">Kerntechnische Entsorgung</collection>
  </doc>
  <doc>
    <id>51099</id>
    <completedYear/>
    <publishedYear>2021</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>121450</pageFirst>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume>221</volume>
    <type>article</type>
    <publisherName>Elsevier B.V.</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Wastewater monitoring by means of e-nose, VE-tongue, TD-GC-MS, and SPME-GC-MS</title>
    <abstract language="eng">The presence of wastewater and air pollution has become an important risk factor for citizens, not only in terms of problems related to health risks, but also because of its negative impact on the country's image. For this reason, malodorous emission monitoring and control techniques are in high demand in urban areas and industries. The aim of this work is first to build an electronic nose (e-nose) and a Voltammetric Electronic tongue (VE-tongue) in order to study their ability to discriminate between polluted and clean environmental samples. Secondly, Thermal Desorption-Gas Chromatography-Mass Spectrometry (TD-GC-MS), and Solid Phase Micro Extraction-Gas Chromatography–Mass Spectrometry (SPME-GC-MS) are utilized to explain this discrimination by identifying specific compounds from these samples. Indeed, the e-nose, consisted of metal oxide semiconductor gas sensors, is used for the assessment of the studied odorous air and headspace samples from water and wastewater sites. Moreover, the VE-tongue, based on metal electrodes, is utilized to determine the patterns of the sensor array responses, which serve as fingerprints profiles of the analyzed liquid samples. Chemometric tools, such as Principal Component Analysis (PCA), Hierarchical Cluster Analysis (HCA), and Support Vector Machines (SVMs) are operated for the processing of data from the e-nose and the VE-tongue. By using the both systems, the analyses of headspace and liquid samples from the seven sites allow better discrimination. To explain the cause of the obtained discrimination, TD-GC-MS and SPME-GC-MS analyses are well performed to identify compounds related sites. According to these outcomes, the proposed e-nose and VE-tongue are proved to be rapid and valuable tools for analysis of environmental polluted matrices.</abstract>
    <parentTitle language="eng">Talanta</parentTitle>
    <identifier type="doi">10.1016/j.talanta.2020.121450</identifier>
    <enrichment key="date_peer_review">26.10.2020</enrichment>
    <author>M. Moufid</author>
    <author>Michael Hofmann</author>
    <author>N. El Bari</author>
    <author>Carlo Tiebe</author>
    <author>Matthias Bartholmai</author>
    <author>B. Bouchikhi</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Wastewater</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Electronic nose</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Voltammetric electronic tongue</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Thermal desorption-gas chromatography-mass spectrometry</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Solid phase micro extraction-gas chromatography–mass spectrometry</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="institutes" number="">8 Zerstörungsfreie Prüfung</collection>
    <collection role="institutes" number="">8.1 Sensorik, mess- und prüftechnische Verfahren</collection>
    <collection role="themenfelder" number="">Umwelt</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="themenfelder" number="">Sensorik</collection>
  </doc>