<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>41864</id>
    <completedYear/>
    <publishedYear>2017</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>Article e00374, 1</pageFirst>
    <pageLast>21</pageLast>
    <pageNumber/>
    <edition/>
    <issue>3</issue>
    <volume/>
    <type>article</type>
    <publisherName>Elsevier Limited</publisherName>
    <publisherPlace>125 London Wall London, EC2Y 5AS United Kingdom</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">In vivo XCT bone characterization of lattice structured implants fabricated by additive manufacturing</title>
    <abstract language="eng">Several cylindrical specimens and dental implants, presenting diagonal lattice structures with different cell sizes (600, 900 and 1200 µm) were additively manufactured by selective laser melting process. Then they were implanted for two months in a sheep. After removal, they were studied by Archimedes’ method as well as X-ray computed tomography in order to assess the penetration of bone into the lattice. We observed that the additive manufactured parts were geometrically conform to the theoretical specifications. However, several particles were left adhering to the surface of the lattice, thereby partly or entirely obstructing the cells. Nevertheless, bone penetration was clearly visible. We conclude that the 900 µm lattice cell size is more favourable to bone penetration than the 1200 µm lattice cell size, as the bone penetration is 84 % for 900 µm against 54 % for 1200 µm cell structures. The lower bone penetration value for the 1200 µm lattice cell could possibly be attributed to the short residence time in the sheep. Our results lead to the conclusion that lattice implants additively manufactured by selective laser melting enable better bone integration.</abstract>
    <parentTitle language="eng">Heliyon</parentTitle>
    <identifier type="doi">10.1016/j.heliyon.2017.e00374</identifier>
    <identifier type="issn">2405-8440</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-418648</identifier>
    <enrichment key="date_peer_review">01.04.2019</enrichment>
    <licence>Creative Commons - Namensnennung - Nicht kommerziell - Keine Bearbeitung 3.0</licence>
    <author>A-F. Obaton</author>
    <author>J. Fain</author>
    <author>M. Djemaï</author>
    <author>Dietmar Meinel</author>
    <author>Fabien Léonard</author>
    <author>E. Mahé</author>
    <author>B. Lécuelle</author>
    <author>J-J. Fouchet</author>
    <author>Giovanni Bruno</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Biomedical engineering</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Dentistry</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Medical imaging</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>X-ray computer tomography</value>
    </subject>
    <collection role="ddc" number="620">Ingenieurwissenschaften und zugeordnete Tätigkeiten</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/41864/DOI10.1016_j.heliyon.2017.e00374.pdf</file>
  </doc>