<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>4717</id>
    <completedYear/>
    <publishedYear>2004</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>8 pages</pageFirst>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>bookpartcollection</type>
    <publisherName>International Committee for Non-Destructive Testing</publisherName>
    <publisherPlace>Montreal</publisherPlace>
    <creatingCorporation>Canadian Institute for NDE</creatingCorporation>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Mobile 3D-X-Ray Tomography for Analysis of Planar Defects in Welds by "Tomocar"</title>
    <abstract language="eng">Tomographical Computer Aided Radiology (TomoCAR) is based on the mechanical position control of
an X-ray tube in front of a welding seam and the application of a planar array detector behind it. Several hundred
radiometric projections in small angle steps are acquired. The tomographical reconstruction allows the three-dimensional
(3D) representation of the defects. A new radiometric array detector system with a small internal
unsharpness and high image contrast is used for the 2- and 3-dimensional visualization and sizing of planar defects
with a defect opening of less than 100 µm. This detector is based on a CMOS-flat panel with a direct converting
CdTe-single crystal layer. The small design allows the application of the mobile testing equipment for mechanized
X-ray inspection in industrial plants. The physical pixel size of the detector amounts to 0,1x0,1 mm². Nevertheless,
this system yields a better spatial resolution than indirect converting detectors (e.g. cameras with fluorescence
layers of Gd2O2S). It allows the reliable detection of planar defects with openings far below the detector pixel size
by subpixel resolution.
'TomoCAR' is qualified at present in the context with a German pilot study following to the ENIQ guidelines for
the employment within the nuclear power industry.</abstract>
    <parentTitle language="eng">16th World Conference on Nondestructive Testing</parentTitle>
    <identifier type="old">4958</identifier>
    <enrichment key="bibliotheksstandort">Sonderstandort: Publica-Schrank</enrichment>
    <enrichment key="eventName">16th World Conference on Nondestructive Testing</enrichment>
    <enrichment key="eventPlace">Montreal, Canada</enrichment>
    <enrichment key="eventStart">2004-08-30</enrichment>
    <enrichment key="eventEnd">2004-09-03</enrichment>
    <author>Bernhard Redmer</author>
    <author>Uwe Ewert</author>
    <author>Christoph Rädel</author>
    <author>Uwe Zscherpel</author>
    <author>A.V. Likhatchov</author>
    <author>V.V. Pickalov</author>
    <author>B. Neundorf</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Digitale Radiologie</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Radiometrie</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Laminografie</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Mobile Anwendungen</value>
    </subject>
    <collection role="fulltextaccess" number="">Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access")</collection>
    <collection role="literaturgattung" number="">Graue Literatur</collection>
  </doc>
  <doc>
    <id>5227</id>
    <completedYear/>
    <publishedYear>2004</publishedYear>
    <thesisYearAccepted/>
    <language>deu</language>
    <pageFirst>1(?)</pageFirst>
    <pageLast>9(?)</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>bookpartcollection</type>
    <publisherName>DGZfP</publisherName>
    <publisherPlace>Berlin</publisherPlace>
    <creatingCorporation>Deutsche Gesellschaft für Zerstörungsfreie Prüfung</creatingCorporation>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="deu">Mobiler Einsatz digitaler Röntgen-Detektoren zur tomografischen Visualisierung flächiger Fehler im Anlagenbereich</title>
    <parentTitle language="deu">ZfP in Forschung, Entwicklung und Anwendung - Jahrestagung 2004</parentTitle>
    <identifier type="old">5528</identifier>
    <identifier type="isbn">3-931381-55-2</identifier>
    <identifier type="url">http://www.ndt.net/article/dgzfp04/papers/v62/v62.htm</identifier>
    <enrichment key="eventName">Jahrestagung Zerstörungsfreie Materialprüfung 2004</enrichment>
    <enrichment key="eventPlace">Salzburg, Österreich</enrichment>
    <enrichment key="eventStart">2004-05-17</enrichment>
    <enrichment key="eventEnd">2004-05-19</enrichment>
    <author>Bernhard Redmer</author>
    <author>Uwe Ewert</author>
    <author>Christoph Rädel</author>
    <author>Uwe Zscherpel</author>
    <author>A.V. Likhatchov</author>
    <author>V.V. Pickalov</author>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Digitale Radiologie</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Zeilenkamera</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Flächendetektor</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Laminografie</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Mobile Anwendungen</value>
    </subject>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Weder Datei noch physisches Exemplar vorhanden ("No Access")</collection>
  </doc>
</export-example>
