<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>56456</id>
    <completedYear/>
    <publishedYear>2022</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>13</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume>224</volume>
    <type>article</type>
    <publisherName>Elsevier Ltd.</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Water flow through bone: Neutron tomography reveals differences in water permeability between osteocytic and anosteocytic bone material</title>
    <abstract language="eng">Vertebrate bones are made of a nanocomposite consisting of water, mineral and organics. Water helps bone material withstand mechanical stress and participates in sensation of external loads. Water diffusion across vertebrae of medaka (bone material lacking osteocytes) and zebrafish (bone material containing osteocytes) was compared using neutron tomography. Samples were measured both wet and following immersion in deuterated-water (D2O). By quantifying H+ exchange and mutual alignment with X-ray lCT scans, the amount of water expelled from complete vertebra was determined. The findings revealed that anosteocytic bone material is almost twice as amenable to D2O diffusion and H2O exchange, and that unexpectedly, far more water is retained in osteocytic zebrafish bone. Diffusion in osteocytic bones (only 33 % – 39 % water expelled) is therefore restricted as compared to anosteocytic bone (~ 60 % of water expelled), presumably because water flow is confined to the lacunar-canalicular network (LCN) open-pore system. Histology and Raman spectroscopy showed that anosteocytic bone contains less proteoglycans than osteocytic bone. These findings identify a previously unknown functional difference between the two bone materials. Therefore, this study proposes that osteocytic bone retains water, aided by non-collagenous proteins, which contribute to its poroelastic mechano-transduction of water flow confined inside the LCN porosity.</abstract>
    <parentTitle language="eng">Materials &amp; Design</parentTitle>
    <identifier type="doi">10.1016/j.matdes.2022.111275</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-564563</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="date_peer_review">05.12.2022</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>A. Silveira</author>
    <author>N. Kardjilov</author>
    <author>Henning Markötter</author>
    <author>E. Longo</author>
    <author>I. Greving</author>
    <author>P. Lasch</author>
    <author>R Shahar</author>
    <author>P. Zaslansky</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Bone porosity</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Anosteocytic bone</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Water permeability</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Neutron tomography</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Proteoglycans</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="institutes" number="">8 Zerstörungsfreie Prüfung</collection>
    <collection role="institutes" number="">8.5 Röntgenbildgebung</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/56456/Silveira_Markoetter_MatDes_final.pdf</file>
  </doc>
  <doc>
    <id>56164</id>
    <completedYear/>
    <publishedYear>2022</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>111037</pageFirst>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume>222</volume>
    <type>article</type>
    <publisherName>Elsevier Ltd.</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Torsion of a rectangular bar: Complex phase distribution in 304L steel revealed by neutron tomography</title>
    <abstract language="eng">Metastable austenitic stainless steel (304L) samples with a rectangular cross-section were plastically deformed in torsion during which they experienced multiaxial stresses that led to a complex martensitic phase distribution owing to the transformation induced plasticity effect. A three-dimensional characterization of the phase distributions in these cm-sized samples was carried out by wavelength-selective neutron tomography. It was found that quantitatively correct results are obtained as long as the samples do not exhibit any considerable preferential grain orientation. Optical microscopy, electron backscatter diffraction, and finite element modeling were used to verify and explain the results obtained by neutron tomography. Altogether, neutron tomography was shown to extend the range of microstructure characterization methods towards the meso- and macroscale.</abstract>
    <parentTitle language="eng">Materials &amp; Design</parentTitle>
    <identifier type="doi">10.1016/j.matdes.2022.111037</identifier>
    <identifier type="issn">0264-1275</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-561649</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="date_peer_review">03.11.2022</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>K. Van Tran</author>
    <author>R. Woracek</author>
    <author>N. Kardjilov</author>
    <author>Henning Markötter</author>
    <author>D. Abou-Ras</author>
    <author>S. Puplampu</author>
    <author>C. Förster</author>
    <author>D. Penumadu</author>
    <author>C. F. O. Dahlberg</author>
    <author>J. Banhart</author>
    <author>I. Manke</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Neutron tomography</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Phase distribution</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Rectangular cross-section</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Torsion</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Geometrical effect</value>
    </subject>
    <collection role="ddc" number="620">Ingenieurwissenschaften und zugeordnete Tätigkeiten</collection>
    <collection role="institutes" number="">8 Zerstörungsfreie Prüfung</collection>
    <collection role="institutes" number="">8.5 Röntgenbildgebung</collection>
    <collection role="themenfelder" number="">Material</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/56164/Van_Tran_torsion_rectangular_bar_spectral_neutron_tomography.pdf</file>
  </doc>
  <doc>
    <id>56910</id>
    <completedYear/>
    <publishedYear>2022</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>13</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume>222</volume>
    <type>article</type>
    <publisherName>Elsevier Ltd.</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Torsion of a rectangular bar: Complex phase distribution in 304L steel revealed by neutron tomography</title>
    <abstract language="eng">Metastable austenitic stainless steel (304L) samples with a rectangular cross-section were plastically deformed in torsion during which they experienced multiaxial stresses that led to a complex martensitic phase distribution owing to the transformation induced plasticity effect. A three-dimensional characterization of the phase distributions in these cm-sized samples was carried out by wavelength-selective neutron tomography. It was found that quantitatively correct results are obtained as long as the samples do not exhibit any considerable preferential grain orientation. Optical microscopy, electron backscatter diffraction, and finite element modeling were used to verify and explain the results obtained by neutron tomography. Altogether, neutron tomography was shown to extend the range of microstructure characterization methods towards the meso- and macroscale.</abstract>
    <parentTitle language="eng">Materials &amp; Design</parentTitle>
    <identifier type="doi">10.1016/j.matdes.2022.111037</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-569101</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>K. V. Tran</author>
    <author>R. Woracek</author>
    <author>N. Kardjilov</author>
    <author>Henning Markötter</author>
    <author>D. Abou-Ras</author>
    <author>S. Puplampu</author>
    <author>C. Förster</author>
    <author>D. Penumadu</author>
    <author>C. F. O. Dahlberg</author>
    <author>J. Banhart</author>
    <author>I. Manke</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Neutron tomography</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Phase distribution</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Rectangular cross-section</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Torsion</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Geometrical effect</value>
    </subject>
    <collection role="ddc" number="620">Ingenieurwissenschaften und zugeordnete Tätigkeiten</collection>
    <collection role="institutes" number="">8 Zerstörungsfreie Prüfung</collection>
    <collection role="institutes" number="">8.5 Röntgenbildgebung</collection>
    <collection role="themenfelder" number="">Material</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/56910/Van_Tran_torsion_rectangular_bar_spectral_neutron_tomography.pdf</file>
  </doc>
  <doc>
    <id>34963</id>
    <completedYear/>
    <publishedYear>2015</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>985</pageFirst>
    <pageLast>991</pageLast>
    <pageNumber/>
    <edition/>
    <issue>11-12</issue>
    <volume>57</volume>
    <type>article</type>
    <publisherName>Hanser</publisherName>
    <publisherPlace>München</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">X-ray compton line scan tomography</title>
    <abstract language="eng">The potentials of incoherent X-ray scattering (Compton) computed tomography (CT) are investigated. The imaging of materials of very different atomic number or density at once is generally a perpetual challenge for X-ray tomography or radiography. In a basic laboratory set-up for simultaneous perpendicular Compton scattering and direct beam attenuation tomography are conducted by single channel photon counting line scans. This results in asymmetric distortions of the projection profiles of the scattering CT data set. In a first approach, corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts. A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials. Comparison to neutron tomography &#13;
reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT offers the potential to replace neutron tomography, which requires much more efforts.</abstract>
    <parentTitle language="eng">Materials testing</parentTitle>
    <identifier type="old">38113</identifier>
    <identifier type="doi">10.3139/120.110799</identifier>
    <identifier type="issn">0025-5300</identifier>
    <enrichment key="date_peer_review">25.11.2015</enrichment>
    <author>Andreas Kupsch</author>
    <author>Axel Lange</author>
    <author>Manfred P. Hentschel</author>
    <author>Gerd-Rüdiger Jaenisch</author>
    <author>N. Kardjilov</author>
    <author>C. Tötzke</author>
    <author>Henning Markötter</author>
    <author>A. Hilger</author>
    <author>I. Manke</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>X-ray compton scattering</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Computed tomography</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Neutron tomography</value>
    </subject>
    <collection role="literaturgattung" number="">Eigenverlag BAM</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
  </doc>
  <doc>
    <id>31972</id>
    <completedYear/>
    <publishedYear>2014</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>9</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName>Brno University of Technology</publisherName>
    <publisherPlace>Brno</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">X-ray compton tomography</title>
    <abstract language="deu">The potentials of incoherent X-ray Scattering (Compton) tomography are investigated. Imaging materials of very different density or atomic number at once is a perpetual challenge for X-ray tomography or radiography, in general. In a basic laboratory set-up for simultaneous perpendicular Compton Scattering and direct beam attenuation tomographic scans are conducted by single channel photon counting. This results in asymmetric distortions of the projection profiles of the scattering CT-data set. ln a first approach corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts.&#13;
A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials.&#13;
Compärison to neutron tomography reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT bears the potential to replace neutron tomography, which requires much more efforts.</abstract>
    <parentTitle language="eng">ECNDT 2014 Proceedings</parentTitle>
    <identifier type="old">35030</identifier>
    <identifier type="isbn">978-80-214-5018-9</identifier>
    <enrichment key="eventName">ECNDT 2014 - 11th European Conference on Non-Destructive Testing</enrichment>
    <enrichment key="eventPlace">Prague, Czech Republic</enrichment>
    <enrichment key="eventStart">06.10.2014</enrichment>
    <enrichment key="eventEnd">10.10.2014</enrichment>
    <enrichment key="date_peer_review">17.11.2014</enrichment>
    <author>Axel Lange</author>
    <author>Manfred P. Hentschel</author>
    <author>Andreas Kupsch</author>
    <author>Gerd-Rüdiger Jaenisch</author>
    <author>N. Kardjilov</author>
    <author>C. Tötzke</author>
    <author>Henning Markötter</author>
    <author>A. Hilger</author>
    <author>I. Manke</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>X-ray compton scattering</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Computed tomography</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Neutron tomography</value>
    </subject>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Graue Literatur</collection>
  </doc>
</export-example>