    <title language="eng">The potential of bioprinting for preparation of nanoparticle-based calibration standards for LA-ICP-ToF-MS quantitative imaging</title>
    <abstract language="eng">This paper discusses the feasibility of a novel strategy based on the combination of bioprinting nano-doping technology and laser ablation-inductively coupled plasma time-of-flight mass spectrometry analysis for the preparation and characterization of gelatin- based multi-element calibration standards suitable for quantitative imaging. To achieve this, lanthanide up-conversion nanoparticles were added to a gelatin matrix to produce the bioprinted calibration standards. The features of this bioprinting approach were com- pared with manual cryosectioning standard preparation, in terms of throughput, between batch repeatability and elemental signal homogeneity at 5 μm spatial resolution. By using bioprinting, the between batch variability for three independent standards of the same concentration of 89 Y (range 0–600 mg/kg) was reduced to 5% compared to up to 27% for cryosectioning. On this basis, the relative standard deviation ( RSD ) obtained between three independent calibration slopes measured within 1 day also reduced from 16% (using cryosectioning ) to 5% (using bioprinting), supporting the use of a single standard preparation replicate for each of the concentrations to achieve good calibration performance using bioprinting. This helped reduce the analysis time by approximately 3-fold. With cryosectioning each standard was prepared and sectioned individually, whereas using bio-printing it was possible to have up to six different standards printed simultaneously, reducing the preparation time from approximately 2 h to under 20 min (by approxi- mately 6-fold). The bio-printed calibration standards were found stable for a period of 2 months when stored at ambient temperature and in the dark.</abstract>
    <parentTitle language="eng">Metallomics</parentTitle>
    <identifier type="doi">10.1093/mtomcs/mfac088</identifier>
    <identifier type="issn">1756-591X</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="date_peer_review">20.02.2023</enrichment>
    <author>K. Billimoria</author>
    <author>Y. A. Diaz Fernandez</author>
    <author>Elina Andresen</author>
    <author>I. Sorzabal-Bellido</author>
    <author>G. Huelga-Suarez</author>
    <author>D. Bartczak</author>
    <author>C. Ortiz de Solórzano</author>
    <author>Ute Resch-Genger</author>
    <author>H. Goenaga Infante</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Environmental analysis</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LA-ICP-MS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Lanthanide</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Tag</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Fluorescence</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Nanoparticles</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Reference material</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Quality assurance</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>3D-printing</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Synthesis</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Production</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Multimodal</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="ddc" number="628">Sanitär- und Kommunaltechnik; Umwelttechnik</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.2 Biophotonik</collection>
    <collection role="themenfelder" number="">Umwelt</collection>
    <collection role="themenfelder" number="">Umwelt-Material-Interaktionen</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="themenfelder" number="">Chemische Charakterisierung und Spurenanalytik</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
  </doc>
</export-example>