<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>55225</id>
    <completedYear/>
    <publishedYear>2022</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>16</pageLast>
    <pageNumber/>
    <edition/>
    <issue>12</issue>
    <volume>12</volume>
    <type>article</type>
    <publisherName>MDPI</publisherName>
    <publisherPlace>Basel</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Molecularly Imprinted Polymers Exhibit Low Cytotoxic and Inflammatory Properties in Macrophages In Vitro</title>
    <abstract language="eng">Molecularly imprinted polymers (MIPs) against sialic acid (SA) have been developed as a detection tool to target cancer cells. Before proceeding to in vivo studies, a better knowledge of the overall effects of MIPs on the innate immune system is needed. The aim of this study thus was to exemplarily assess whether SA-MIPs lead to inflammatory and/or cytotoxic responses when administered to phagocytosing cells in the innate immune system. The response of monocytic/macrophage cell lines to two different reference particles, Alhydrogel and PLGA, was compared to their response to SA-MIPs. In vitro culture showed a cellular association of SA-MIPs and Alhydrogel, as analyzed by flow cytometry. The reference particle Alhydrogel induced secretion of IL-1b from the monocytic cell line THP-1, whereas almost no secretion was provoked for SA-MIPs. A reduced number of both THP-1 and RAW 264.7 cells were observed after incubation with SA-MIPs and this was not caused by cytotoxicity. Digital holographic cytometry showed that SA-MIP treatment affected cell division, with&#13;
much fewer cells dividing. Thus, the reduced number of cells after SA-MIP treatment was not linked to SA-MIPs cytotoxicity. In conclusion, SA-MIPs have a low degree of inflammatory properties, are not cytotoxic, and can be applicable for future in vivo studies.</abstract>
    <parentTitle language="eng">Applied Sciences</parentTitle>
    <identifier type="doi">10.3390/app12126091</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-552250</identifier>
    <identifier type="issn">2076-3417</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="date_peer_review">11.07.2022</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>L. Sternbaek</author>
    <author>Martha Wamaitha Kimani</author>
    <author>Kornelia Gawlitza</author>
    <author>Knut Rurack</author>
    <author>B. Janicke</author>
    <author>K. Alm</author>
    <author>A. Gjörloff-Wingren</author>
    <author>H. Eriksson</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Molecularly imprinted polymers</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Digital holographic cytometry</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Cytotoxicity</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Proinflammatory cytokines</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="ddc" number="620">Ingenieurwissenschaften und zugeordnete Tätigkeiten</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.9 Chemische und optische Sensorik</collection>
    <collection role="themenfelder" number="">Umwelt</collection>
    <collection role="themenfelder" number="">Material</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <collection role="themenfelder" number="">Materialdesign</collection>
    <collection role="themenfelder" number="">Sensorik</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/55225/Sternbaek_2022.pdf</file>
  </doc>
  <doc>
    <id>52521</id>
    <completedYear/>
    <publishedYear>2021</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>2363</pageFirst>
    <pageLast>2373</pageLast>
    <pageNumber/>
    <edition/>
    <issue>5</issue>
    <volume>3</volume>
    <type>article</type>
    <publisherName>American Chemical Society</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Imprinted Particles for Direct Fluorescence Detection of Sialic Acid in Polar Media and on Cancer Cells with Enhanced Control of Nonspecific Binding</title>
    <abstract language="eng">Glycoproteins are abundant on the cell surface of mammals, providing structural support, modulating cell Membrane properties, and acting as signaling agents. Variation of glycosylation patterns has been found to indicate various disease states, including cell malignancy. Sialic acid (SA) is present as a terminating group on cell-surface glycans, and its overexpression has been linked to several types of cancer. Detection of SA on the cell surface is therefore critical for detection of cancer in its early stages. In this work, a fluorescent molecularly imprinted polymer layer targeting SA was synthesized on the surface of silica-coated polystyrene (PS) particles. Compared to previous works, a PS core supplies a lighter, lower-density support for improved suspension stability and scattering properties. Moreover, their smaller size provides a higher surface-area-to-volume ratio for binding. The incorporation of a fluorescent monomer in the MIP shell allowed for simple and rapid determination of binding specificity in polar media due to a deprotonation−reprotonation interaction mechanism between the fluorescent monomer and SA, which led to spectral changes.&#13;
Upon titration of the MIP particles with SA in suspension, an increase in fluorescence emission of the particles was observed, with the MIP particles binding SA more selectively compared to the nonimprinted polymer (NIP) control particles. In cell staining experiments performed by flow cytometry, the binding behavior of the MIP particles compared favorably with that of SA-binding lectins. NIPs prepared with a “dummy” template served as a better negative control in cell binding assays due to the favorable inward orientation of template-binding functional groups in the polymer shell, which reduced nonspecific binding. The results show that fluorescent MIPs targeting SA are a promising tool for in vitro fluorescence staining of cancerous cells and for future diagnosis of cancer at early stages.</abstract>
    <parentTitle language="eng">ACS Applied Polymer Materials</parentTitle>
    <identifier type="doi">10.1021/acsapm.0c01353</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-525216</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="date_peer_review">07.06.2021</enrichment>
    <licence>Creative Commons - CC BY-NC-ND - Namensnennung - Nicht kommerziell - Keine Bearbeitungen 4.0 International</licence>
    <author>Martha Wamaitha Kimani</author>
    <author>S. Beyer</author>
    <author>Z. El-Schich</author>
    <author>Kornelia Gawlitza</author>
    <author>Knut Rurack</author>
    <author>A. Gjörloff-Wingren</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Flow cytometry</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Sialic acid</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Fluorescence</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Molecularly imprinted polymers</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Cancer cells</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.9 Chemische und optische Sensorik</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/52521/acsapm.0c01353.pdf</file>
  </doc>
  <doc>
    <id>47793</id>
    <completedYear/>
    <publishedYear>2019</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>21</pageFirst>
    <pageLast>23</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume>21</volume>
    <type>report</type>
    <publisherName>Wiley</publisherName>
    <publisherPlace>Imaging and Microscopy</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Digital Holographic Cytometry: Macrophage Uptake of Nanoprobes</title>
    <abstract language="eng">Digital holographic cytometry (DHC) is a state-of-the-art quantitative Phase imaging (QPI) method that permits time-lapse imaging of cells without induced cellular toxicity. DHC platforms equipped with semi-automated image segmentation and analysis software packages for assessing cell behavior are commercially available. In this study we investigate the possible uptake of nanoprobes in macrophages in vitro over time.</abstract>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>L. Sternbaek</author>
    <author>Martha Wamaitha Kimani</author>
    <author>Kornelia Gawlitza</author>
    <author>B. Janicke</author>
    <author>K. Alm</author>
    <author>A. Gjörloff-Wingren</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Macrophages</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>MIPs</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Holographic microscopy</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Sialic acid</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
  </doc>