<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>62326</id>
    <completedYear/>
    <publishedYear>2024</publishedYear>
    <thesisYearAccepted/>
    <language>deu</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>lecture</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="deu">Neues Klassifizierungssystem für Lithiumbatterien</title>
    <abstract language="deu">Um Lithiumbatterien sicherer aber gleichzeitig auch dem Gefährdungszustand angemessener und damit wirtschaftlich effizienter transportieren zu können, wird aktuell bei UN ein Klassifizierungssystem nach Gefährlichkeit ausgearbeitet. Als eine der intensiv mitarbeitenden zuständigen Behörden weltweit hat die BAM zahlreiche Untersuchungen selbst durchgeführt und arbeitet an Lösungsansätzen mit.</abstract>
    <enrichment key="eventName">Gefahrguttag des BMDV im Rahmen der IAA</enrichment>
    <enrichment key="eventPlace">Hannover, Germany</enrichment>
    <enrichment key="eventStart">19.09.2024</enrichment>
    <enrichment key="eventEnd">19.09.2024</enrichment>
    <enrichment key="InvitedTalks">1</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>Anita Schmidt</author>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Lithiumbatterien</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Klassifizierung</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Gefahrguttransport</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Gefährlichkeit</value>
    </subject>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="institutes" number="">3 Gefahrgutumschließungen; Energiespeicher</collection>
    <collection role="institutes" number="">3.1 Sicherheit von Gefahrgutverpackungen und Batterien</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Elektrische Energiespeicher und -umwandlung</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Präsentation</collection>
  </doc>
  <doc>
    <id>62959</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>168</pageFirst>
    <pageLast>174</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume>2025</volume>
    <type>conferenceobject</type>
    <publisherName>ICCEX</publisherName>
    <publisherPlace>Prag</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Testing of vacuum insulation panels for liquid hydrogen storage tanks</title>
    <abstract language="eng">Vacuum insulation panel (VIP) based insulation could present an alternative to the common double walled vacuum insulation for large liquefied Hydrogen (LH2) storage tanks. In this paper a brief introduction on VIPs and the envisioned design of VIP-based LH2-tank insulation is given. The design of a flat plate boil-off calorimeter for the testing of the insulation concept is shown, with regard to thermal design, mechanical design and instrumentation. Finally, an overview over the particular challenges for modelling VIP-based insulation and the proposed testing to be performed on the test rig is presented.</abstract>
    <parentTitle language="eng">The 18th Cryogenics 2025 IIR Conference</parentTitle>
    <identifier type="issn">978-2-36215-053-1</identifier>
    <identifier type="isbn">0151-1637</identifier>
    <identifier type="doi">10.18462/iir.cryo.2025.0010</identifier>
    <enrichment key="eventName">18th Cryogenics IIR International Conference</enrichment>
    <enrichment key="eventPlace">Prague, Czech Republic</enrichment>
    <enrichment key="eventStart">07.04.2025</enrichment>
    <enrichment key="eventEnd">11.04.2025</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>Finn Harwege</author>
    <author>Heiko Schmidt</author>
    <author>Robert Eberwein</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Liquefied Hydrogen</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Insulation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Calorimeter</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Vacuum Insulation Panel</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LH2</value>
    </subject>
    <collection role="ddc" number="604">Spezielle Themen</collection>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="institutes" number="">3 Gefahrgutumschließungen; Energiespeicher</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Graue Literatur</collection>
    <collection role="institutes" number="">3.5 Sicherheit von Gasspeichern und Gefahrguttanks</collection>
    <collection role="themenfelder" number="">Wasserstoff</collection>
    <collection role="themenfelder" number="">Gefährliche Stoffe</collection>