    <title language="eng">Development of a fully automated slurry sampling introduction system for GF-AAS and its application for the determination of cadmium in different matrices</title>
    <abstract language="eng">element analysis, offering high sensitivity and precision. However, its effectiveness is limited by sample preparation challenges for solid samples like soils and microplastics. Traditional methods include sample preparation, such as digestion, which is time-consuming and involves reagents, like acids, contributing to measurement uncertainty and higher carbon footprints. Slurry sampling allows direct analysis of suspensions, offering a more efficient alternative. However, maintaining suspension stability is challenging, requiring robust autosampler systems to streamline the process and enhance analytical performance.&#13;
Results: We present a novel autosampler extension for slurry sample introduction into GF-AAS. This system ensures suspension stability with a stirring device and closed vessels to prevent evaporation and contamination, incorporating a cooling unit to reduce solvent and analyte losses. It installs and removes in minutes without&#13;
additional connections. Validation with cadmium analysis in BAM-U110 (Soil) and BAM-H010 (ABS) showed high reliability. For BAM-U110 (Soil), we achieved recovery rates of 94 % ± 13 % in water suspension. The recovery rate for BAM-H010 (ABS) was 104 % ±11 % in acetonitrile suspension. These results demonstrate the system’s robustness, versatility, and accuracy for different matrices.&#13;
Significance:&#13;
The autosampler extension helps solve key problems in trace element analysis of solid samples, making the process faster and more accurate. It works well with complex materials, making it useful for areas like microplastic or nanoparticle analysis. This improvement also helps meet regulations for monitoring environ mental and polymer samples, offering a reliable and flexible tool for high-throughput analysis with fewer errors.</abstract>
    <parentTitle language="eng">Analytica Chimica Acta</parentTitle>
    <identifier type="doi">10.1016/j.aca.2024.343460</identifier>
    <identifier type="issn">0003-2670</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-618531</identifier>
    <enrichment key="opus_doi_flag">true</enrichment>
    <enrichment key="opus_import_data">{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,11,29]],"date-time":"2024-11-29T02:10:20Z","timestamp":1732846220834,"version":"3.30.0"},"reference-count":17,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,11,23]],"date-time":"2024-11-23T00:00:00Z","timestamp":1732320000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100009553","name":"BAM Federal Institute for Materials Research and Testing","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100009553","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Analytica Chimica Acta"],"published-print":{"date-parts":[[2025,1]]},"DOI":"10.1016\/j.aca.2024.343460","type":"journal-article","created":{"date-parts":[[2024,11,21]],"date-time":"2024-11-21T02:12:01Z","timestamp":1732155121000},"page":"343460","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Development of a fully automated slurry sampling introduction system for GF-AAS and its application for the determination of cadmium in different matrices"],"prefix":"10.1016","volume":"1335","author":[{"ORCID":"http:\/\/orcid.org\/0000-0003-2440-3181","authenticated-orcid":false,"given":"Charlie","family":"Tobias","sequence":"first","affiliation":[]},{"given":"Lennart","family":"Gehrenkemper","sequence":"additional","affiliation":[]},{"given":"Thomas","family":"Bernstein","sequence":"additional","affiliation":[]},{"given":"Sven","family":"Schlau","sequence":"additional","affiliation":[]},{"given":"Fabian","family":"Simon","sequence":"additional","affiliation":[]},{"given":"Mathias","family":"R\u00f6llig","sequence":"additional","affiliation":[]},{"given":"Bj\u00f6rn","family":"Meermann","sequence":"additional","affiliation":[]},{"ORCID":"http:\/\/orcid.org\/0000-0002-7225-7396","authenticated-orcid":false,"given":"Marcus","family":"von der Au","sequence":"additional","affiliation":[]}],"member":"78","reference":[{"key":"10.1016\/j.aca.2024.343460_bib1","doi-asserted-by":"crossref","first-page":"3778","DOI":"10.1039\/D0AY01049A","article-title":"Substituting HF by HBF 4\u2013an optimized digestion method for multi-elemental sediment analysis via ICP-MS\/MS","volume":"12","author":"Zimmermann","year":"2020","journal-title":"Anal. Methods"},{"key":"10.1016\/j.aca.2024.343460_bib2","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0236120","article-title":"A metrologically traceable protocol for the quantification of trace metals in different types of microplastic","volume":"15","author":"Hildebrandt","year":"2020","journal-title":"PLoS One"},{"key":"10.1016\/j.aca.2024.343460_bib3","doi-asserted-by":"crossref","first-page":"1391","DOI":"10.1039\/b307581h","article-title":"Measurement uncertainty from physical sample preparation: estimation including systematic error","volume":"128","author":"Lyn","year":"2003","journal-title":"Analyst"},{"key":"10.1016\/j.aca.2024.343460_bib4","doi-asserted-by":"crossref","DOI":"10.1016\/j.greeac.2023.100051","article-title":"Carbon footprint of the analytical laboratory and the three-dimensional approach to its reduction","volume":"4","author":"Nowak","year":"2023","journal-title":"Green Analytical Chemistry"},{"key":"10.1016\/j.aca.2024.343460_bib5","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1007\/s00216-019-02195-1","article-title":"Calibration strategies for elemental analysis of biological samples by LA-ICP-MS and LIBS - a review","volume":"412","author":"Martinez","year":"2020","journal-title":"Anal. Bioanal. Chem."},{"key":"10.1016\/j.aca.2024.343460_bib6","doi-asserted-by":"crossref","DOI":"10.1016\/j.trac.2023.117277","article-title":"New approaches of slurry sampling as an alternative technique of sample preparing for elemental analysis","volume":"167","author":"Cerqueira","year":"2023","journal-title":"TrAC, Trends Anal. Chem."},{"key":"10.1016\/j.aca.2024.343460_bib7","doi-asserted-by":"crossref","first-page":"1331","DOI":"10.1039\/an9891401331","article-title":"Direct determination of beryllium in coal slurries using graphite furnace atomic absorption spectrometry with automatic injection","volume":"114","author":"Haraldsen","year":"1989","journal-title":"Analyst"},{"key":"10.1016\/j.aca.2024.343460_bib8","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1039\/ja9890400157","article-title":"Palladium as a chemical modifier for the determination of lead in food slurries by electrothermal atomisation atomic absorption spectrometry","volume":"4","author":"Lynch","year":"1989","journal-title":"J. Anal. Atomic Spectrom."},{"key":"10.1016\/j.aca.2024.343460_bib9","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1016\/0039-9140(90)80126-Z","article-title":"Development of a slurry atomization method for the determination of cadmium in food samples by electrothermal atomization atomic-absorption spectrometry","volume":"37","author":"Lynch","year":"1990","journal-title":"Talanta"},{"key":"10.1016\/j.aca.2024.343460_bib10","doi-asserted-by":"crossref","first-page":"763","DOI":"10.1039\/JA9930800763","article-title":"Inter-laboratory note. Simple stirring device for a slurry sampling technique in electrothermal atomic absorption spectrometry","volume":"8","author":"Do\u010dekal","year":"1993","journal-title":"J. Anal. Atomic Spectrom."},{"key":"10.1016\/j.aca.2024.343460_bib11","doi-asserted-by":"crossref","first-page":"1303","DOI":"10.1016\/0584-8547(93)80117-D","article-title":"Robotized sampling device for graphite furnace atomic absorption spectrometry slurry analysis with Varian SpectrAA instruments","volume":"48","author":"Hoenig","year":"1993","journal-title":"Spectrochim. Acta B Atom Spectrosc."},{"key":"10.1016\/j.aca.2024.343460_bib12","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1039\/D3AY02116E","article-title":"Green direct ultrasonic slurry sampling and electrothermal atomic absorption spectrometry method for metal analysis of solid plastics samples","volume":"16","author":"Chovancova","year":"2024","journal-title":"Anal. Methods"},{"key":"10.1016\/j.aca.2024.343460_bib13","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1007\/s00216-020-03010-y","article-title":"Determination of organically bound fluorine sum parameters in river water samples-comparison of combustion ion chromatography (CIC) and high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS)","volume":"413","author":"Gehrenkemper","year":"2021","journal-title":"Anal. Bioanal. Chem."},{"key":"10.1016\/j.aca.2024.343460_bib14","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/j.sab.2011.04.004","article-title":"Method development for the determination of cadmium in fertilizer samples using high-resolution continuum source graphite furnace atomic absorption spectrometry and slurry sampling","volume":"66","author":"Borges","year":"2011","journal-title":"Spectrochim. Acta B Atom Spectrosc."},{"key":"10.1016\/j.aca.2024.343460_bib15","doi-asserted-by":"crossref","first-page":"4647","DOI":"10.1007\/s00216-019-01698-1","article-title":"Screening method for extractable organically bound fluorine (EOF) in river water samples by means of high-resolution-continuum source graphite furnace molecular absorption spectrometry (HR-CS GF MAS)","volume":"411","author":"Metzger","year":"2019","journal-title":"Anal. Bioanal. Chem."},{"key":"10.1016\/j.aca.2024.343460_bib16","doi-asserted-by":"crossref","DOI":"10.1016\/j.chemosphere.2022.133922","article-title":"A fast and simple PFAS extraction method utilizing HR-CS-GFMAS for soil samples","volume":"295","author":"Simon","year":"2022","journal-title":"Chemosphere"},{"key":"10.1016\/j.aca.2024.343460_bib17","doi-asserted-by":"crossref","first-page":"1835","DOI":"10.1016\/S0584-8547(02)00140-4","article-title":"Modifiers and coatings in graphite furnace atomic absorption spectrometry\u2014mechanisms of action (A tutorial review)","volume":"57","author":"Ortner","year":"2002","journal-title":"Spectrochim. Acta B Atom Spectrosc."}],"container-title":["Analytica Chimica Acta"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003267024012613?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003267024012613?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,11,29]],"date-time":"2024-11-29T01:47:00Z","timestamp":1732844820000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0003267024012613"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1]]},"references-count":17,"alternative-id":["S0003267024012613"],"URL":"http:\/\/dx.doi.org\/10.1016\/j.aca.2024.343460","relation":{},"ISSN":["0003-2670"],"issn-type":[{"type":"print","value":"0003-2670"}],"subject":[],"published":{"date-parts":[[2025,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Development of a fully automated slurry sampling introduction system for GF-AAS and its application for the determination of cadmium in different matrices","name":"articletitle","label":"Article Title"},{"value":"Analytica Chimica Acta","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.aca.2024.343460","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Authors. Published by Elsevier B.V.","name":"copyright","label":"Copyright"}],"article-number":"343460"}}</enrichment>
    <enrichment key="local_crossrefDocumentType">journal-article</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="date_peer_review">06.01.2025</enrichment>
    <enrichment key="PaperofMonth">1</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Charlie Tobias</author>
    <author>Lennart Gehrenkemper</author>
    <author>Thomas Bernstein</author>
    <author>Sven Schlau</author>
    <author>Fabian Simon</author>
    <author>Mathias Röllig</author>
    <author>Björn Meermann</author>
    <author>Marcus von der Au</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Slurry AAS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Soil</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Cd</value>
    </subject>
    <collection role="ddc" number="628">Sanitär- und Kommunaltechnik; Umwelttechnik</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.1 Anorganische Spurenanalytik</collection>
    <collection role="institutes" number="">1.4 Non-Target-Analytik</collection>
    <collection role="institutes" number="">8 Zerstörungsfreie Prüfung</collection>
    <collection role="institutes" number="">8.3 Thermografische Verfahren</collection>
    <collection role="institutes" number="">9 Komponentensicherheit</collection>
    <collection role="institutes" number="">9.2 Versuchsanlagen und Prüftechnik</collection>
    <collection role="themenfelder" number="">Umwelt</collection>
    <collection role="themenfelder" number="">Umwelt-Material-Interaktionen</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/61853/Analytica Chimica Acta 1335 (2025) 343460.pdf</file>
  </doc>
</export-example>