Dokument-ID Dokumenttyp Autoren/innen Persönliche Herausgeber/innen Haupttitel Abstract Auflage Verlagsort Verlag Herausgeber (Institution) Erscheinungsjahr Titel des übergeordneten Werkes Jahrgang/Band ISBN Veranstaltung Veranstaltungsort Beginndatum der Veranstaltung Enddatum der Veranstaltung Ausgabe/Heft Erste Seite Letzte Seite URN DOI Lizenz Datum der Freischaltung OPUS4-26106 Zeitschriftenartikel Buchholz, Uwe; Jaunich, Matthias; Stark, Wolfgang; Habel, Wolfgang; Petersson, B.A.T. Acoustic data of cross linked polyethylene (XLPE) and cured liquid silicone rubber (LSR) by means of ultrasonic and low frequency DMTA Partial discharges may cause damage to electrical insulation of high voltage equipment. They initiate elastic waves in the insulating material, e.g. in the stress cone of an outdoor termination. Localisation of the origin of such elastic waves can help to predict serious damaging processes in the electrical insulation. In order to measure and evaluate the wave propagation effects in typical multilayered elastomeric structures, knowledge of the material properties is required. The propagating velocity and the attenuation of longitudinal waves are important parameters. Values for these quantities found in the literature were not appropriate. Therefore, for cross-linked polyethylene (XLPE) and cured liquid silicone rubber (LSR), the longitudinal wave velocity and the attenuation were evaluated in the temperature interval from -20°C to 50°C and in the frequency range from 200 kHz to 600 kHz using a two-sample ultrasound technique. The loss factor was determined from these measured quantities. Additionally, low frequency Dynamic Mechanical Thermal Analysis (DMTA) was applied to investigate LSR and XLPE in a temperature interval between -100 and 50°C and to check qualitatively the ultrasound data. New York, NY Institute of Electrical and Electronics Engineers 2012 IEEE transactions on dielectrics and electrical insulation 19 2 558 566 10.1109/TDEI.2012.6180250 2016-02-19 OPUS4-28530 Beitrag zu einem Tagungsband Wolff, Dietmar; Jaunich, Matthias; Stark, Wolfgang Investigating the performance of rubber seals at low temperatures Rubbers are widely used as main sealing materials for Containers for low and intermediate level radioactive waste and as additional component to metal seals in spent fuel and high active waste containers. The save enclosure of the radioactive container inventory has to be guaranteed according to legislation and appropriate guidelines for long term storage periods as well as down to temperatures of -40 °C for transportation. Therefore the understanding of failure mechanisms that lead to leakage at low temperatures is necessary to ensure a proper material choice which is certainly also influenced by additional factors as e.g. the aging behavior. Omnipress American nuclear society (ANS) 2013 IHLRWM 2013 - 14th International high-level radioactive waste management conference (Proceedings) 978-1-62748-644-6 14th International high-level radioactive waste management conference Albuquerque, New Mexico, USA 28.04.2013 02.05.2013 1 7(Paper # 6888) 2016-02-20 OPUS4-26190 Beitrag zu einem Tagungsband Jaunich, Matthias; Stark, Wolfgang; Wolff, Dietmar Low temperature - For a seal this depends on the applied material Frankfurt am Main Deutsche Kautschuk-Gesellschaft 2012 DKT 2012 - German Rubber Conference DKT 2012 - German Rubber Conference Nuremberg, Germany 2012-07-02 2012-07-05 10-2330_5-L-1530 1 4 2016-02-19 OPUS4-28574 Beitrag zu einem Tagungsband Jaunich, Matthias; Stark, Wolfgang; Wolff, Dietmar Behaviour of rubber seals at low temperatures - results of component tests - The investigation of low temperature properties of elastomeric sealing materials by means of thermo-analytical methods is a sound way to get information about the glass transition process. The breakdown temperature of the sealing function of O-ring seals was measured in a component test setup depending on material and degree of compression. An in depth explanation of the observed component tests behaviour is currently in preparation. It requires the results of thermo-analytical methods and measurements as the compression set (not shown here). With that, a model was developed to describe the correlation between physical material parameters and observed component behaviour. Kerntechnische Gesellschaft e.V. (KTG) 2013 Jahrestagung Kerntechnik 2013 (Proceedings) Jahrestagung Kerntechnik 2013 Berlin, Germany 14.05.2013 16.05.2013 1 6 2016-02-20 OPUS4-24971 Beitrag zu einem Tagungsband Jaunich, Matthias; Schulz, Sebastian; Stark, Wolfgang; Wolff, Dietmar Characterization of the low temperature behaviour of rubber sealing materials Rubbers are often used for seal applications due to their special material properties and easy use. In many applications the material is exposed to low temperatures during Operation. Therefore it is important to know the material behavior at low temperatures to determine the temperature ränge that allows a Safe Operation of the seal, e.g. in storage and transport Containers for radioactive materials. The seal function of an elastomer is limited in temperature by the rubber-glass transition during which the material properties change from rubber-like to stiff and glass-like. For a given application this correlation is not trivial and therefore needs an in-depth investigation under consideration of the physical properties and the application conditions. In this work different analytical methods are used to characterize the material behavior at low temperature in the ränge of the glass-rubber-transition and are compared with the quality of Operation of a component which is here defined by the detected leakage rate. 2011 Technomer 2011 - 22. Fachtagung über Verarbeitung und Anwendung von Polymeren 978-3-939382-10-2 Technomer 2011 - 22. Fachtagung über Verarbeitung und Anwendung von Polymeren Chemnitz, Deutschland 10.11.2011 12.11.2011 Kap. 3.7 1 4 2016-02-19 OPUS4-26291 Zeitschriftenartikel Stark, Wolfgang; Jaunich, Matthias; Bohmeyer, W.; Lange, K. Investigation of the crosslinking behaviour of ehtylene vinyl acetate (EVA) for solar cell encapsulation by rheology and ultrasound EVA is a widely used material for the encapsulation of photovoltaic modules. It melts at elevated temperatures, and seals the module before it is crosslinked at temperatures above 130 °C by a peroxide-initiated crosslinking reaction. EVA has good optical properties necessary for application in solar modules. For process optimization and quality management, a method for the quick and reliable characterization of EVA crosslinking behaviour is of great value. Here, the practicability of ultrasound for online crosslinking monitoring is demonstrated. A sound velocity increase of about 8 m/s during the crosslinking reaction is found. The ultrasound results are compared with rheometer measurements performed with a curemeter typically used for the investigation of rubber crosslinking. Amsterdam [u.a.] Elsevier Science 2012 Polymer testing 31 7 904 908 10.1016/j.polymertesting.2012.07.004 2016-02-19 OPUS4-18574 Beitrag zu einem Tagungsband Jaunich, Matthias; Stark, Wolfgang; Hoster, B. In-situ vulcanization monitoring by ultrasonic wave propagation Deutsches Institut für Kautschuktechnologie e.V. 2008 8. Kautschuk-Herbst-Kolloquium, 26.- 28.11.2008, Hannover (Proceedings) 8. Kautschuk-Herbst-Kolloquium Hannover, Deutschland 2008-11-26 2008-11-28 133 2016-02-19 OPUS4-29067 Zeitschriftenartikel Stark, Wolfgang; Jaunich, Matthias; McHugh, J. Cure state detection for pre-cured carbon-fibre epoxy prepreg (CFC) using temperature-modulated differential scanning calorimetry (TMDSC) Carbon-fibre prepregs have found widespread use in lightweight applications. They are based on a carbon-fibre fabric impregnated with reactive epoxy resin. Prepreg materials are generally pre-cured so that they have a higher molecular weight than typical resins in order to reduce resin flow, which facilitates storage and later processing properties. The measurements were carried out using commercially available materials and follow the published DMA investigations of the same material. TMDSC was used to find the correlation between curing conditions, the degree of cure and glass transition temperature. TMDSC has the advantage over standard DSC that it enables better determination of the glass transition temperature, which is often accompanied by an exothermic curing reaction, and thus overshadowed. The influence of the amplitude of temperature modulation was tested in preliminary experiments. For non-cured material a glass transition temperature of approximately 0 °C was determined; whereas for the totally cured material it was approximately 230 °C. The changes in degree of cure, temperature of actual glass transition and post-reaction are given as a function of curing time at 180 °C. The correlation between actual glass transition temperature and degree of cure is derived. Amsterdam [u.a.] Elsevier Science 2013 Polymer Testing 32 7 1261 1272 10.1016/j.polymertesting.2013.07.007 2016-02-20 OPUS4-29221 Beitrag zu einem Tagungsband Jaunich, Matthias; Wolff, Dietmar; Stark, Wolfgang Riedl, A. Was passiert bei tiefen Temperaturen? - Dichtungsverhalten im Bereich des Glasübergangs Elastomere werden vielfach als Dichtungsmaterial für verschiedene Anwendungen eingesetzt. In vielen Bereichen ist die Funktion der Dichtung auch bei tiefen Temperaturen erforderlich. Daher ist das Verständnis des Versagensmechanismus von großer Bedeutung. Normalerweise werden Elastomere oberhalb ihres Glass-Gummi Umwandlungsbereiches eingesetzt, wobei die minimale Einsatztemperatur nicht exakt definiert ist. Daher ist es sinnvoll, diese untere Temperatureinsatzgrenze in Abhängigkeit von den Materialeigenschaften zu bestimmen. Hierfür werden die Ergebnisse der thermischen Analyse mit den Resultaten des Druckverformungsrests aus einer abgewandelten Messung mit der Dynamisch Mechanischen Analyse (DMA) kombiniert. Weiterhin werden Ergebnisse von Bauteilversuchen vorgestellt und diskutiert. Die vorgestellten Untersuchungen wurden zum großen Teil auf Untersuchungen im Rahmen der Dissertation von M. Jaunich durchgeführt. Vulkan 2013 XVIII. Dichtungskolloquium - Sichere und zuverlässige Dichtverbindungen 978-3-8027-2216-5 XVIII. Dichtungskolloquium - Sichere und zuverlässige Dichtverbindungen Rheine, Germany 25.09.2013 26.09.2013 51 58 2016-02-20 OPUS4-29616 Beitrag zu einem Tagungsband Jaunich, Matthias; Stark, Wolfgang; Wolff, Dietmar Druckverformungsrest bei tiefen Temperaturen Für Elastomenwerkstoffe im Allgemeinen und im Bereich der Dichtungstechnik im Besonderen ist der Druckverformungsrest eine wichtige Kenngröße zur Beurteilung der Eignung eines Werkstoffs bzw. der Funktion eines Bauteils. Er ermöglicht eine Einschätzung des zeitabhängigen Rückstellverhaltens eines Werkstoffs nach Deformation. Dieses ist für Dichtungen von besonderer Bedeutung, da der Test deren Einbauzustand nachstellt. Oft wird er, bei der Prüfung unter erhöhten Temperaturen, zur Beurteilung des Alterungsverhaltens verwendet und kann anhand eines definierten Versagenskriteriums zur Lebensdauerabschätzung eingesetzt werden. Bei tiefen Temperaturen dient er dazu, die limitierende Einsatztemperatur zu bestimmen. Dabei spielt eine Alterung im eigentlichen Sinne nur eine untergeordnete Rolle, wohl aber physikalische Effekte wie Tieftemperaturkristallisation und Glasübergang. Diese Effekte sind weit weniger durch lange Lagerzeiten beeinflusst als die eigentliche Alterung. Die Versuchsdurchführung unterscheidet sich je nach angewandter Norm und kann einen deutlichen Einfluss auf den Druckverformungsrest haben. Alle standardisierten Methoden sind aufgrund der langen Lagerzeiten relativ langwierig und erfordern das regelmäßige Eingreifen durch den Prüfer. Zusätzlich sehen einige Methoden nur die Bestimmung eines einzelnen Wertes nach einer definierten Zeit vor. Um die Messungen zu beschleunigen wurde eine Methode entwickelt, die automatisch die erforderlichen Messungen bei mehreren Temperaturen durchführt. Dazu wird ein Prüfgerät der Dynamisch Mechanischen Analyse verwendet, das kontinuierlich die Deformation während eines frei programmierbaren Temperaturzyklus misst, wodurch eine sehr große Datenmenge verfügbar ist. Ein Vergleich der neuen Methode mit den Ergebnissen des nach ISO 815 genormten Messprinzips ergibt eine gute Übereinstimmung. Ergebnisse der neuen Methode werden vorgestellt und die Vorzüge der kontinuierlichen Datenerfassung, z.B. für die Materialauswahl, diskutiert. Die vorgestellten Ergebnisse beziehen sich zum großen Teil auf die in beschriebenen Untersuchungen und Ergebnisse. Technische Universität Chemnitz 2013 Technomer 2013 - 23. Fachtagung über Verarbeitung und Anwendung von Polymeren 978-3-939382-11-9 Technomer 2013 - 23. Fachtagung über Verarbeitung und Anwendung von Polymeren Chemnitz, Germany 14.11.2013 15.11.2013 Kapitel V 3.4 1 8 2016-02-20