TY - CONF A1 - Epple, Niklas A1 - Sanchez Trujillo, Camila Andrea A1 - Hau, Julia A1 - Niederleithinger, Ernst A1 - Malm, F. T1 - Structural Monitoring in an Urban Underground Metro Station Using Cod T2 - NDTCE 2025 - Conference Proceedings N2 - Active ultrasonic monitoring with coda wave interferometry has demonstrated its potential for structural Health monitoring in concrete structures. This study investigates its application using ultrasonic transducers embedded in the ceiling of a subway station in Munich, Germany. We evaluate the impact of environmental conditions, specifically electromagnetic interference and temperature, on data quality, as well as the influence of regular loading from passing trams. Results indicate that electromagnetic interference significantly affects measurements, while temperature effects remain minimal due to the station’s stable thermal environment. Long-term measurements and a controlled load test show that both dynamic and static loading from trams induce ultrasonic velocity changes of only 0.01%–0.06%. Although the experiment demonstrates the capacity to detect structural responses and supports the feasibility of long-term monitoring, improved electromagnetic shielding and Hardware reliability are required for successful future applications. T2 - NDT-CE 2025 CY - Izmir, Turkey DA - 24.09.2025 KW - Coda Wave Interferometry (CWI) KW - Structural health monitoring (SHM) KW - Concrete KW - Ultrasonic testing KW - Urban infrastructure PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-654619 DO - https://doi.org/10.58286/31706 SN - 1435-4934 SP - 1 EP - 10 PB - e-Journal of Nondestructive Testing (eJNDT) AN - OPUS4-65461 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -