TY - CONF A1 - Mair, Georg W. A1 - Bock, Robert T1 - Key points in compressed hydrogen storage N2 - This presentation highlights some key points in hydrogen safety related to compressed HYDROGEN STORAGE. It explains some needs concerning the Market ramp-up: cost and safety related aspects like Risk-control by consequence and/or frequency limitation. Other aspects are the optimization of design and test standards by using Monte-Carlo based assessments and the Generation of probabilistic data as input for risk management tools during the design type approval and periodic inspection. Further safety aspects of design and manufacturing have to be taken into account as well as aspects of operational safety with material degradation, non-destructive testing and appropriate tools for operational files. T2 - The opening of BAM hydrogen refueling station CY - Horstwalde, Germany DA - 03.07.2025 KW - Market ramp-up KW - Consequence limitation KW - Frequency limitation KW - Accoustic emission KW - Monte-Carlo PY - 2025 AN - OPUS4-63810 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -