TY - CONF A1 - Harwege, Finn A1 - Schmidt, Heiko A1 - Eberwein, Robert T1 - Testing of vacuum insulation panels for liquid hydrogen storage tanks T2 - The 18th Cryogenics 2025 IIR Conference N2 - Vacuum insulation panel (VIP) based insulation could present an alternative to the common double walled vacuum insulation for large liquefied Hydrogen (LH2) storage tanks. In this paper a brief introduction on VIPs and the envisioned design of VIP-based LH2-tank insulation is given. The design of a flat plate boil-off calorimeter for the testing of the insulation concept is shown, with regard to thermal design, mechanical design and instrumentation. Finally, an overview over the particular challenges for modelling VIP-based insulation and the proposed testing to be performed on the test rig is presented. T2 - 18th Cryogenics IIR International Conference CY - Prague, Czech Republic DA - 07.04.2025 KW - Liquefied Hydrogen KW - Insulation KW - Calorimeter KW - Vacuum Insulation Panel KW - LH2 PY - 2025 SN - 0151-1637 DO - https://doi.org/10.18462/iir.cryo.2025.0010 SN - 978-2-36215-053-1 VL - 2025 SP - 168 EP - 174 PB - ICCEX CY - Prag AN - OPUS4-62959 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -