TY - CONF A1 - Pelkner, Matthias A1 - Stegemann, Robert A1 - Sonntag, Nadja A1 - Cabeza, Sandra A1 - Lyamkin, Viktor A1 - Bruno, Giovanni A1 - Skrotzki, Birgit A1 - Kreutzbruck, Marc T1 - Evaluation of high spatial resolution imaging of magnetic stray fields for early damage detection N2 - Metal magnetic memory (MMM) technique with associated ISO 24497-1:3 is gaining considerable interest in the magnetic NDT community. In contrast to traditional Magnetic Flux Leakage (MFL) testing, the inspection objects are not intentionally magnetized by an external magnetic field. Due to the physical coupling between mechanical stress and magnetization of ferromagnetic materials, it is assumed that the distribution of the residual MFL correspond to the internal stress of the specimen, or in the most general sense, to a degradation of the material. Usually, MMM measurements are performed by relatively bulky magnetic inspection sensors. The evaluation of local magnetic field distribution is limited thereby. Highprecision GMR (Giant Magneto Resistance) measurements in the micrometer regime can provide a higher degree of information due to better spatial resolution. We present a concise summary of studies on the correlation of magnetic structure and microstructure of steels. In particular, we compare residual stress measurements in S235JRC steel welds by means of neutron diffraction with high resolution magnetic field mappings. Results indicate a qualitative correlation between residual stresses and local stray field variation. In addition, stray field measurements of plastically deformed specimens for quasi-static and cyclic loading cases are discussed. The present study concludes that GMR sensors can detect inhomogeneous plastic deformations of S235JR steel in a very early stage, without specific signal processing according to the ISO 24497-1:3. T2 - QNDE - Review of Progress in Quantitative Nondestructive Evaluation CY - Atlanta, Georgia, USA DA - 18.07.2016 KW - NDT KW - MMM KW - GMR PY - 2016 AN - OPUS4-37101 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -