TY - CONF A1 - Voigt, Marieke A1 - Gardei, Andre A1 - Meng, Birgit ED - di Prisco, M. ED - Meda, A. ED - Balazs, G.L. T1 - The adaption of the set-up for gas permeability measurements for ultra-high performance concrete T2 - Proceedings of the 14th fib PhD symposium in Civil Engineering N2 - In the framework of this project, a steam pressure vessel was to be developed from ultra-high perfor-mance concrete (UHPC) to withstand process temperatures of 200 °C and the respective steam pressure of 15,5 bar. To guarantee the long-term water vapour tightness of the system, the permeability of two UHPC mixtures were tested after long-term cyclic autoclaving. As UPHC shows a high density and therefore low permeability, measurements after the RILEM-Recommendation (TC 116-PCD) reached their detection limit. Therefore, the measurement set-up was adapted to measure the permeability of highly dense UHPC more reliably and quickly. This adaption includes measurements in a higher pres-sure range, the change of sample size thickness and the usage of Ar as a medium compared with the RILEM Recommendation. Additionally, the system was equipped with two pressure sensors and Ar-flowmeters to guarantee a continuous record of the experimental parameters. The new system was tested and evaluated by comparing measurements with the RILEM recommended system. Preliminary results show that the adapted system is capable to provide efficient and reliable results of concrete with low permeability. T2 - 14th fib PhD Symposium in Civil Engineering CY - Rom, Italy DA - 05.09.2022 KW - Durability KW - UHPC KW - gas permeability PY - 2022 SN - 978-2-940643-17-2 SN - 2617-4820 VL - 58 SP - 353 EP - 359 AN - OPUS4-56862 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -