TY - CONF A1 - Schilling, Richard A1 - Oehrl, A. A1 - Wischerhoff, E. A1 - Schukar, Marcus T1 - A fibre optic temperature sensor based on thermoresponsive polymer T2 - Proceedings of SPIE 12643 N2 - We present a temperature sensor based on a polymer exhibiting a Lower Critical Solution Temperature (LCST) in aqueous solution encapsulated in a capillary. Parameters are chosen such that the solution exhibits a cloud point in a temperature range of 30° C to 39°C. The characteristic of thermoresponsive polymers with an LCST, is that above that temperature phase separation of the polymer takes place which leads to a temperature-dependent formation of a cloudy suspension. An optical intensity measurement over the desired temperature range is established by an increase of optical attenuation inside the polymer solution caused by a rising temperature. For our purpose, the polymer capillary is connected to transmitter and receiver via a Polymer Optical Fibre (POF). Our intensity measurement is, to the best of our knowledge, a novel method and can be considered simple when compared to existing fibre-based temperature measurement techniques. Due to the lack of electrical components at the probe, this sensor is suitable for measurements in strong electromagnetic fields and environments for which flying sparks are hazardous, i.e., inflammable fluids or gases. Furthermore, all manufactured sensors share the same temperature dependence and, therefore, are well-suited for comparative measurement, e.g., flow measurement systems. With the given temperature range, a body temperature measurement is also suitable. PB - SPIE CY - Bellingham, Wash. T2 - European Workshop on Optical Fibre Sensors (EWOFS 2023) CY - Mons, Belgium DA - 23.05.2023 KW - Thermoresponsive polymer KW - Aqueous polymer solution KW - Temperature sensor KW - LCST KW - POF PY - 2023 UR - https://opus4.kobv.de/opus4-bam/frontdoor/index/index/docId/57735 AN - OPUS4-57735 SP - 12643-69 AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany