TY - CONF A1 - Wosniok, Aleksander A1 - Jansen, R. A1 - Chen, L. A1 - Toet, P. A1 - Doppenberg, E. A1 - De Jong, W. A1 - Chruscicki, Sebastian T1 - Static load monitoring of a concrete bridge using a high-precision distributed fiber optic sensor system T2 - SMAR 2019 - Proceedings N2 - In the present study, the impact of static traffic loading on the slight deflection effects in the concrete structure of an existing bridge has been investigated using distributed fiber optic sensors. In the face of increasing traffic density and severe traffic loading, the results of the load tests on the Amsterdam bridge 705 make an important contribution to the understanding of its structural behavior. The concept of the static loading was based on the use of two 36-ton trucks stopped on the bridge at multiple pre-determined locations. The load applied in this way led to location-dependent small deflection effects recorded as longitudinal strain of the sensing fiber embedded at the underside of the bridge. The measurements were performed with a commercially-available solution based on Tunable Wavelength Coherent Optical Time Domain Reflectometry with the measurement accuracy in the range of 0.5 µm/m. T2 - 5th International Conference on Smart Monitoring, Assessment and Rehabilitation of Civil Structures CY - Potsdam, Germany DA - 27.08.2019 KW - Bridge monitoring KW - Distributed fiber optic sensing KW - Static load monitoring KW - TW-COTDR PY - 2019 UR - https://opus4.kobv.de/opus4-bam/frontdoor/index/index/docId/49040 AN - OPUS4-49040 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-490408 SP - 1 EP - 8 AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany