TY - CONF A1 - Bletzer, Claus T1 - CONFIRE Temperture development during fire test of a final storagr container Typ V N2 - This presentation focusses on the thermal test of a typical storage container design for the German final storage repository KONRAD. The preparation of the container, the conduction of the fire test itself and results like the temperature evolution and as-sumptions for thermal material properties are shown. As thermal test final storage containers have to be exposed to a fire of 800 °C (1472 °F) for 1 hour according to the final storage conditions provided by the federal com-pany for radioactive waste disposal (BGE). The here discussed cask contains a steel covered concrete layer of a thickness of 100/150 mm. Heating up concrete is a highly nonlinear process since the vaporization of residual water consumes high amounts of thermal energy and produce vast amounts of steam. The constantly measured temperatures provide the basis to adjust common models of thermal properties for concrete esp. for FEAs. Finally in a later step this will allow predictions of similar designed container with different sizes. T2 - SNL BAM Workshop CY - Albuquerque, NM, USA DA - 14.03.2018 KW - KONRAD KW - Fire testing KW - Concrete KW - Final storage KW - Thermal properties PY - 2018 AN - OPUS4-45427 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -