TY - CONF A1 - Hübert, Thomas A1 - Majewski, J. A1 - Banach, Ulrich A1 - Detjens, Marc A1 - Tiebe, Carlo T1 - Response Time Measurement of Hydrogen Sensors T2 - Proceedings of 7th International Conference on Hydrogen Safety (ICHS 2017) N2 - The efficiency of gas sensor application for facilitating the safe use of hydrogen depends considerably on the sensor response to a change in hydrogen concentration. Therefore, the response time has been measured for five different-type commercially available hydrogen sensors. Experiments showed that all these sensors surpass the ISO 26142 standard; for the response times t90 values of 2 s to 16 s were estimated. Results can be fitted with an exponential or sigmoidal function. It can be demonstrated that the results on transient behaviour depend on both the operating parameters of sensors and Investigation methods, as well as on the experimental conditions: gas change rate and concentration jump. T2 - 7th International Conference on Hydrogen Safety (ICHS 2017) CY - Hamburg, Germany DA - 11.09.2017 KW - Response time KW - Hydrogen sensor KW - Test facility KW - t90 value PY - 2017 UR - https://opus4.kobv.de/opus4-bam/frontdoor/index/index/docId/47592 AN - OPUS4-47592 SN - 978-88-902391 SP - 1251 EP - 1261 AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany