TY - GEN A1 - Spitzer, Stefan T1 - Comparative study on standardized ignition sources used for explosion testing N2 - For the determination of safety characteristics of gases, vapors and dusts different types of ignition sources are used in international standards and guidelines. Table 1 compares technical relevant ignition sources with their main features. The paper presents test results of a comparative calorimetric and visual study between four different types of ignition sources. The ignition procedures were analyzed visually with a high-speed camera and electric recordings. In addition to that, the influence of the electrode-orientation, -distance as well as ignition energy on the reproducibility of the exploding wire igniter was tested. The exploding wire is already in use for standardized determination of safety characteristics of gases, first tests on the suitability of the exploding wire igniter for dust testing have been carried out by Scheid et al. Using the exploding wire, the ignition energy can be varied from 2 to 10 000 J (2 x 5 000 J) and thus it could be used for gases, vapors, dusts and hybrid mixtures. Moreover it can be used at high initial pressures and it is the only ignition source with an easily measurable ignition energy release. Furthermore, it does not introduce another chemical reaction into the system. Finally, a proposal for a standard ignition source for explosion tests on hybrid mixtures is derived from the test results. T2 - 13th International Symposium on Hazards, Prevention and Mitigation of Industrial Explosions CY - Braunschweig, Germany DA - 27.07.2020 KW - Ignition source KW - Exploding Wire KW - Safety characteristics determination KW - Hybrid mixtures PY - 2020 UR - https://opus4.kobv.de/opus4-bam/frontdoor/index/index/docId/51691 AN - OPUS4-51691 AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany