TY - CONF A1 - Talebi, Elnaz A1 - Korzen, Manfred A1 - Espinós, A. A1 - Hothan, Sascha A2 - Albero, Vicente T1 - The effect of damage location on the performance of seismically damaged concrete filled steel tube columns at fire T2 - Proceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures (ASCCS 2018) N2 - In this paper, a nonlinear three-dimensional finite element (FE) model was developed and validated to study the effect of seismic damage location on the response of concrete filled tube (CFT) columns at fire after earthquakes. Three analyses were conducted consecutively in the modelling, namely, cyclic, thermal and structural. Results of the cyclic loading analysis comprising residual deformations were applied as the Initial condition to the thermal-stress model, replicating the seismic performance of column. Following, a nonlinear sequentially coupled-thermal stress Analysis was carried out to investigate the fire response of CFT columns after the seismic event. Three damage scenarios were contemplated, considering any possible potential damages that could be generated by the earthquake loading on CFT columns. The accuracy of the proposed FE model was examined by comparing the numerical results with that of available tests on fire and cyclic loading. By means of the validated model, the performance of damaged CFT columns was then investigated under fire after earthquakes. The level of damage was assumed as a high damage level, presuming that the column reached 50% of ist lateral resistance while still maintaining its overall stability after the earthquake. The results were presented broadly, including the axial deformation history as well as the fire resistance time for CFT columns. To have a comprehensive insight on the influence of damage location in columns, the fire response of damaged specimens was compared with that of an intact one. PB - Editorial Universitat Politècnica de València CY - València T2 - 12th International Conference on Advances in Steel-Concrete Composite Structures (ASCCS 2018) CY - Valencia, Spain DA - 27.06. 2018 KW - Fire after earthquake KW - Concrete filled tube (CFT) column KW - Finite element model KW - Seismically damaged column KW - Damage location KW - Fire performance PY - 2018 UR - https://opus4.kobv.de/opus4-bam/frontdoor/index/index/docId/45769 AN - OPUS4-45769 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-457694 SN - 978-84-9048-601-6 SP - 835 EP - 842 AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany