TY - CONF A1 - Pelkner, Matthias A1 - Neubauer, Andreas A1 - Reimund, Verena A1 - Kreutzbruck, Marc ED - Thompson, D. O. ED - Chimenti, D. E. T1 - Local magnetization unit for GMR array based magnetic flux leakage inspection T2 - Review of progress in quantitative nondestructive evaluation, volume 31 N2 - GMR sensors are increasingly used for magnetic surface inspection due to their high sensitivity and high spatial resolution. In case of simple planar or cylindrical shaped components, the GMR-based inspection procedure can be automated easily. We present GMR measurements of real fatigue cracks. In addition, we present a probe design using a local magnetization unit and commercially available GMR sensors. The design was carried out by means of finite-element method (FEM) simulations. Using the local probe we measured bearings containing artificial reference cracks of different depths and orientations. Cracks with a depth of 40 µm could be resolved with a signal-to-noise ratio better than 6. A further reduction of the measuring time can be obtained using a sensor array. For this purpose we present a study of the optimized size of the sensing GMR-layers for a NDE-adapted sensor array. The geometric sensor parameters were investigated through simulations of the magnetic flux leakage of surface cracks using an analytic model. T2 - 38th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Burlington, VT, USA DA - 2011-07-17 KW - GMR KW - Magnetic flux leakage KW - NDE KW - Sensor array PY - 2012 SN - 978-0-7354-1013-8 DO - https://doi.org/10.1063/1.4716332 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings IS - 1430 SP - 1005 EP - 1012 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-26107 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -