TY - JOUR A1 - Oberleitner, Lidia A1 - Dahmen-Levison, U. A1 - Garbe, L.-A. A1 - Schneider, Rudolf T1 - Application of fluorescence polarization immunoassay for determination of carbamazepine in wastewater T2 - Journal of Environmental Management N2 - Carbamazepine is an antiepileptic drug that can be used as a marker for the cleaning efficiency of wastewater treatment plants. Here, we present the optimization of a fast and easy on-site measurement system based on fluorescence polarization immunoassay and the successful application to wastewater. A new monoclonal highly specific anti-carbamazepine antibody was applied. The automated assay procedure takes 16 min and does not require sample preparation besides filtration. The recovery rates for carbamazepine in wastewater samples were between 60.8 and 104% with good intra- and inter-assay coefficients of variations (less than 15 and 10%, respectively). This automated assay enables for the onsite measurement of carbamazepine in wastewater treatment plants. PB - Elsevier Ltd. KW - On-site measurement KW - Wastewater treatment plant KW - Fluorescence polarization immunoassay KW - Assay optimization KW - Mix-and-read assay PY - 2017 UR - https://opus4.kobv.de/opus4-bam/frontdoor/index/index/docId/39152 AN - OPUS4-39152 SN - 0301-4797 SN - 1095-8630 VL - 193 SP - 92 EP - 97 AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany