TY - JOUR A1 - Köppen, Robert A1 - Becker, Roland A1 - Esslinger, Susanne A1 - Nehls, Irene T1 - Enantiomer-specific analysis of hexabromocyclododecane in fish from Etnefjorden (Norway) T2 - Chemosphere N2 - High-performance liquid chromatography tandem mass spectrometry (HPLC–MS/MS) was applied to sterospecifically quantify the content of α-, β-, and γ-hexabromocyclododecane (HBCD) in six fish species from the Norwegian Etnefjorden. A combination of a β-PM cyclodextrin and an achiral column enabled the paired chromatographic separation of the stereoisomers in the order (-)-α-, (+)-α-, (-)-β-, (+)-β-, (+)-γ- and, (-)-γ-HBCD. The limits of detection were in the range of 6–21 pg g-1 depending on the stereoisomer and the concentrations of α-, β-, and γ-HBCD in fillets ranged from <5.4 ng g-1 to 11.1 µg g-1 lipid weight. α-HBCD enantiomers were throughout dominating, and in most cases the accumulation of the respective first eluted enantiomers ((-)-α-, (-)-β- and (+)-γ-HBCD) was observed. Deviations from the racemic EF-value were considered to be significant if it was outside of the expanded uncertainty range for each of the racemic HBCD-ratios. The composition of HBCD isomers varied between the investigated fish species and the relative high values for the γ-HBCD concentrations for the bottom-dwellers flounder and thorny skate seems to echo the HBCD pattern of ocean sediments. PB - Elsevier Science CY - Kidlington, Oxford KW - Flame retardant KW - Diastereomers KW - Chiral separation KW - Bioaccumulation KW - Enantiomeric fraction PY - 2010 UR - https://opus4.kobv.de/opus4-bam/frontdoor/index/index/docId/22377 AN - OPUS4-22377 SN - 0045-6535 SN - 0366-7111 VL - 80 IS - 10 SP - 1241 EP - 1245 AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany