Within the apron of the opencast mine Jänschwalde (SE Brandenburg, Germany) archaeological excavations on a
multiple populated small dune were complemented with soil-geomorphological investigations in the vicinity. Archaeological findings in the dune stratigraphy (especially cremation graves) are intercalated within aeolian sediments and/or buried soils and thus give a record of the Late Quaternary geomorphodynamic and soil development.
Background: The 3D printing is relevant as a manufacturing technology of functional models for forensic, pharmaceutical and bioanalytical applications such as drug delivery systems, sample preparation and point-of-care tests.
Objective: Melting behavior and autofluorescence of materials are decisive for optimal printing and applicability of the product which are influenced by varying unknown additives.
Methods: We have produced devices for bioanalytical applications from commercially available thermoplastic polymers using a melt-layer process. We characterized them by differential scanning calorimetry, fluorescence spectroscopy and functional assays (DNA capture assay, model for cell adhesion, bacterial adhesion and biofilm formation test).
Results: From 14 tested colored, transparent and black materials we found only deep black acrylonitrile-butadiene-styrene (ABS) and some black polylactic acid (PLA) useable for fluorescence-based assays, with low autofluorescence only in the short-wave range of 300-400 nm. PLA was suitable for standard bioanalytical purposes due to a glass transition temperature of approximately 60°C, resistance to common laboratory chemicals and easy print processing. For temperature-critical methods, such as hybridization reactions up to 90°C, ABS was better suited.
Conclusions: Autofluorescence was not a disadvantage per se but can also be used as a reference signal in assays. The rapid development of individual protocols for sample processing and analysis required the availability of a material with consistent quality over time. For fluorescence-based assays, the use of commercial standard materials did not seem to meet this requirement.