Objectives: To determine the incidence of gentamicin vestibulotoxicity with current dosing regimens, and to evaluate the feasibility of routine video-oculography on all patients given gentamicin. Materials and methods: In this prospective incidence study serial horizontal vestibulo-ocular reflex (HVOR) gain measurements were recorded using video-oculography on adult inpatients receiving intravenous gentamicin. The primary outcome was the proportion of patients developing impairment of their HVOR gain. Results: After exclusions, 42 patients were included in the analysis. Three patients (7.1%) developed asymptomatic vestibulotoxicity, exact 95% confidence interval 1.5-19.5%. In two of these patients the deficit resolved within several hours. No patients developed symptomatic vestibulotoxicity. There was no evidence for a generalised reduction in group HVOR gain with time. HVOR gain was not associated with total gentamicin dose, dynamic visual acuity or subjective imbalance. Conclusions and significance: Gentamicin may cause reversible, asymptomatic vestibulotoxicity. Video-oculography may be useful to monitor for vestibulotoxicity in patients treated with gentamcin; however, testing all patients routinely may be challenging.
Eye tracking for assessment of workload: a pilot study in an anaesthesia simulator environment
(2011)
Objective
The alternate cover test (ACT) in patients with acute vestibular syndrome is part of the ‘HINTS’ battery test. Although quantitative, the ACT is highly dependent on the examiner’s experience and could theoretically vary greatly between examiners. In this study, we sought to validate an automated video-oculography (VOG) system based on eye tracking and dedicated glasses.
Methods
We artificially induced a vertical strabismus to simulate a skew deviation on ten healthy subjects, aged from 26 to 66, using different press-on Fresnel prisms on one eye while recording eye position with VOG of the contralateral eye. We then compared the system’s performance to that of a blinded trained orthoptist using conventional, semi-quantitative method of skew measurement known as the alternate prism cover test (APCT) as a gold standard.
Results
We found a significant correlation between the reference APCT and the Skew VOG (Pearson’s R2 = 0.606, p < 0.05). There was a good agreement between the two tests (intraclass correlation coefficient 0.852, 95 CI 0.728–0.917, p < 0.001). The overall accuracy of the VOG was estimated at 80.53% with an error rate of 19.46%. There was no significant difference in VOG skew estimations compared with the gold standard except for very small skews.
Conclusions
VOG offers an objective and quantitative skew measurement and proved to be accurate in measuring vertical eye misalignment compared to the ACT with prisms. Precision was moderate, which mandates a sufficient number of tests per subject.