Sujoy Kumar Ghosh, Tridib Kumar Sinha, Mengying Xie, Christopher Rhys Bowen, Samiran Garain, Biswajit Mahanty, Krittish Roy, Karsten Henkel, Dieter Schmeißer, Jin Kuk Kim, Dipankar Mandal
- The design and development of intrinsically stretchable all-organic self-powered sensors concurrently perceiving temperature and pressure remain a challenge but deliver an exciting platform to realize environmentally friendly wearable electronics. In this approach, a biomimetic all-organic stretchable energy harvester is designed by a xylitol-added poly(3,4-ethylenedioxythiophene):poly(4-styrenesulfonate) (PEDOT:PSS/Xyl) film as a compatible overlay electrode with polyaniline-reinforced one-dimensional aligned poly(vinylidene fluoride) hybrid electroactive soft nanowires. The gradient of elastic modulus between the electrode and the active nanowire component enables the all-organic device to manifest excellent power-generating performance under external temperature fluctuation (∼3 μW/m2 under ΔT ∼ 92 K) and mechanical force (∼31 μW/cm2 at 30 N). Importantly, the device renders simultaneous energy scavenging of temperature and pressure changes under pressing and stretching conditions (∼20%). The excellent mechanosensitivity (∼100The design and development of intrinsically stretchable all-organic self-powered sensors concurrently perceiving temperature and pressure remain a challenge but deliver an exciting platform to realize environmentally friendly wearable electronics. In this approach, a biomimetic all-organic stretchable energy harvester is designed by a xylitol-added poly(3,4-ethylenedioxythiophene):poly(4-styrenesulfonate) (PEDOT:PSS/Xyl) film as a compatible overlay electrode with polyaniline-reinforced one-dimensional aligned poly(vinylidene fluoride) hybrid electroactive soft nanowires. The gradient of elastic modulus between the electrode and the active nanowire component enables the all-organic device to manifest excellent power-generating performance under external temperature fluctuation (∼3 μW/m2 under ΔT ∼ 92 K) and mechanical force (∼31 μW/cm2 at 30 N). Importantly, the device renders simultaneous energy scavenging of temperature and pressure changes under pressing and stretching conditions (∼20%). The excellent mechanosensitivity (∼100 mV/N), fast response time (∼1 ms), outstanding mechanical and thermal stability, and good temperature resolution <10 K enable the harvester to act as an epidermal sensor, which simultaneously detects and discriminates both subtle pressure and thermal deviations exposed to an epidermis surface. The real-time recording and wireless transferring of physiological signals to a smartphone indicate an effective way to realize remote healthcare monitoring for early intervention.…
![show more show more](/opus4-UBICO/layouts/opus4/img/arrow_down.png)
![show less show less](/opus4-UBICO/layouts/opus4/img/arrow_up.png)