TY - GEN A1 - Kazak, Fedor A1 - Schleuß, Leander A1 - Ossenbrink, Ralf A1 - Michailov, Vesselin A1 - Weiß, Sabine T1 - Particularities of testing structured sheet metals in 3-point bending tests T2 - Materials Testing N2 - Thin sheet metals from deep drawing steel DC04 are very often used in the production of car body and case parts. Quality improvement of sheet metal components by new constructive solutions (structuring) as well as adapted joining technology is going on. Structured sheet metals differ from each other by their high bending stiffness. At the same time, they show certain anisotropy due to the structure. Therefore a typical testing method of structured semi-finished parts (single sheet metals, sandwiches)is the bending test. The literature review revealed that in many studies no special demands on tests of structured materials were made. This concerns particularly the structure arrangement, structure direction and structure location of the specimen relative to the mandrel position during bending tests, i. e., the direction of the fixed load relative to the structure. The aim of this study was to determine the influence of the test specification on flexural behavior. In the present paper, honeycomb-structured sheet metals were examined using 3-point bending tests. Bending stiffness and lightweight potential were calculated with respect to the location of load application and compared for different structure arrangements,directions and locations. The influence of the anisotropy on flexural behavior of the honeycomb-patterned sheet metals was moderate. Y1 - 2016 U6 - https://doi.org/10.3139/120.110883 SN - 0025-5300 SN - 2195-8572 VL - 58 IS - 6 SP - 495 EP - 500 ER - TY - GEN A1 - Naveed, Muhammad A1 - Flores Renteria, Arturo A1 - Weiß, Sabine T1 - Role of alloying elements during thermocyclic oxidation of β/γ-TiAl alloys at high temperatures T2 - Journal of Alloys and Compounds N2 - Gamma titanium aluminides are promising alloys known for their good mechanical properties and low densities, but their low oxidation resistance at high temperatures limits their application. This work discusses the thermocyclic oxidation behavior of newly developed β/γ-TiAl alloys at temperatures between 600 °C and 900 °C. An influence of β-stabilizing alloying elements like Nb and V on the oxidation of these alloys has been investigated here. The selected alloys are tested in an in-house developed thermocyclic furnace. The oxidation study is supported by gravimetric measurements along with Scanning Electron Microscopy (SEM) and Electron Diffraction Spectroscopy (EDS) mapping of the oxide layers. Additionally, phase formation after oxidation has been determined using X-Ray Diffraction (XRD). Results show that the Nb containing alloys are more oxidation resistant as compared to V containing alloys. The formation of a mixture of Al2O3 and TiO2 layers was found for all the alloys. The oxide kinetics controlled oxide growth and formation of various phases at different testing temperatures. KW - Aluminum oxide KW - γ-TiAl KW - thermocyclic oxidation KW - β-stabilizing elements Y1 - 2016 U6 - https://doi.org/10.1016/j.jallcom.2016.08.259 SN - 0925-8388 VL - 691 SP - 489 EP - 497 ER - TY - GEN A1 - Bambach, Markus A1 - Sizova, Irina A1 - Bolz, Sebastian A1 - Weiß, Sabine T1 - Devising Strain Hardening Models Using Kocks-Mecking Plots - A Comparison of Model Development for Titanium Aluminides and Case Hardening Steel T2 - Metals KW - titanium aluminides alloy KW - single phase steel KW - hot forming Y1 - 2016 U6 - https://doi.org/10.3390/met6090204 SN - 2075-4701 VL - 6 IS - 9 SP - 204 ER - TY - GEN A1 - Naveed, Muhammad A1 - Obrosov, Aleksei A1 - Zak, Andrzej A1 - Dudzinski, Wlodzimierz A1 - Volinsky, Alex A. A1 - Weiß, Sabine T1 - Sputtering Power Effects on Growth and Mechanical Properties of Cr2AlC MAX Phase Coatings T2 - Metals N2 - Coating growth and mechanical properties of nanolamellar Cr2AlC coatings at various sputtering power were investigated in the present study. Cr2AlC coating was deposited on the IN 718 superalloy and (100) Si wafers by DC magnetron sputtering at different sputtering powers. The structure and properties were characterized using X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and nanoindentation. It was found that coatings had columnar structure with nanocrystalline substructure. Deposition rate increased with the sputtering power. XRD results showed the presence of the Cr2AlC MAX phase, intermetallic AlCr2 and Cr7C3 carbide phases, along with the change in preferential coating growth orientation. TEM observations confirmed the occurrence of these phases, and the SAED patterns demonstrated significant texture of the coatings. Hardness values were measured in the range between 11–14 GPa, showing a slight increase with the sputtering power. KW - MAX Phase KW - Cr2AlC KW - TEM Y1 - 2016 U6 - https://doi.org/10.3390/met6110265 SN - 2075-4701 VL - 6 IS - 11 SP - 265 ER - TY - GEN A1 - Obrosov, Aleksei A1 - Naveed, Muhammad A1 - Volinsky, Alex A. A1 - Weiß, Sabine T1 - Substrate Frequency Effects on CrxN Coatings Deposited by DC Magnetron Sputtering T2 - Journal of Materials Engineering and Performance N2 - Controlled ion bombardment is a popular method to fabricate desirable coating structures and modify their properties. Substrate biasing at high frequencies is a possible technique, which allows higher ion density at the substrate compared with DC current bias. Moreover, high ion energy along with controlled adatom mobility would lead to improved coating growth. This paper focuses on a similar type of study, where effects of coating growth and properties of DC magnetron-sputtered chromium nitride (CrxN) coatings at various substrate bias frequencies are discussed. CrxN coatings were deposited by pulsed DC magnetron sputtering on Inconel 718 and (100) silicon substrates at 110, 160 and 280 kHz frequency at low duty cycle. Coating microstructure and morphology were studied by X-ray diffraction (XRD), atomic force microscopy (AFM), scanning electron microscopy (SEM), scratch adhesion testing and nanoindentation. Results indicate a transformation of columnar into glassy structure of CrxN coatings with the substrate bias frequency increase. This transformation is attributed to preferential formation of the Cr2N phase at high frequencies compared with CrN at low frequencies. Increase in frequency leads to an increase in deposition rate, which is believed to be due to increase in plasma ion density and energy of the incident adatoms. An increase in coating hardness along with decrease in elastic modulus was observed at high frequencies. Scratch tests show a slight increase in coating adhesion, whereas no clear increase in coating roughness can be found with the substrate bias frequency. KW - adhesion of coatings KW - CrN coatings KW - frequency KW - mechanical properties KW - microstructure KW - PVD KW - X-ray diffraction Y1 - 2016 UR - http://link.springer.com/article/10.1007/s11665-016-2426-4 U6 - https://doi.org/10.1007/s11665-016-2426-4 SN - 1544-1024 VL - 26 IS - 1 SP - 366 EP - 373 ER - TY - GEN A1 - Obrosov, Aleksei A1 - Gulyaev, Roman A1 - Zak, Andrzej A1 - Ratzke, Markus A1 - Naveed, Muhammad A1 - Dudzinski, Wlodzimierz A1 - Weiß, Sabine T1 - Chemical and Morphological Characterization of Magnetron Sputtered at Different Bias Voltages Cr-Al-C Coatings T2 - Materials N2 - MAX phases (M = transition metal, A = A-group element, and X = C/N) are of special interest because they possess a unique combination of the advantages of both metals and ceramics. Most attention is attracted to the ternary carbide Cr2AlC because of its excellent high-temperature oxidation, as well as hot corrosion resistance. Despite lots of publications, up to now the influence of bias voltage on the chemical bonding structure, surface morphology, and mechanical properties of the film is still not well understood. In the current study, Cr-Al-C films were deposited on silicon wafers (100) and Inconel 718 super alloy by dc magnetron sputtering with different substrate bias voltages and investigated using Scanning Electron Microscopy (SEM), X-ray Photoelectron Spectroscopy (XPS), X-ray Diffraction (XRD), Atomic Force Microscopy (AFM), and nanoindentation. Transmission Electron Microscopy (TEM) was used to analyze the correlation between the growth of the films and the coating microstructure. The XPS results confirm the presence of Cr2AlC MAX phase due to a negative shift of 0.6–0.9 eV of the Al2p to pure aluminum carbide peak. The XRD results reveal the presence of Cr2AlC MAX Phase and carbide phases, as well as intermetallic AlCr2. The film thickness decreases from 8.95 to 6.98 µm with increasing bias voltage. The coatings deposited at 90 V exhibit the lowest roughness (33 nm) and granular size (76 nm) combined with the highest hardness (15.9 GPa). The ratio of Al carbide to carbide-like carbon state changes from 0.12 to 0.22 and correlates with the mechanical properties of the coatings. TEM confirms the columnar structure, with a nanocrystalline substructure, of the films. KW - XPS KW - AFM KW - MAX phase KW - TEM KW - chemical bonding KW - surface morphology Y1 - 2017 UR - http://www.mdpi.com/1996-1944/10/2/156/htm U6 - https://doi.org/10.3390/ma10020156 SN - 1996-1944 VL - 10 IS - 2 SP - 156 ER - TY - GEN A1 - Obrosov, Aleksei A1 - Gulyaev, Roman A1 - Ratzke, Markus A1 - Volinsky, Alex A. A1 - Bolz, Sebastian A1 - Naveed, Muhammad A1 - Weiß, Sabine T1 - XPS and AFM Investigations of Ti-Al-N Coatings Fabricated Using DC Magnetron Sputtering at Various Nitrogen Flow Rates and Deposition Temperatures T2 - Metals N2 - Ti-Al-N coatings were deposited by direct current magnetron sputtering (DCMS) onto IN 718 at different nitrogen flow rates and deposition temperatures. The coatings’ properties were characterized using atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS) as well as nanoindentation. It was found that higher deposition temperature leads to higher surface roughness and nitrogen flux influences the shape of grains. According to XPS, the bonding structure of all coatings exhibited the (Ti,Al)N phase. Mechanical properties depend on the Al content within the films. The coating with the best mechanical properties (deposited at 500 °C and 20 standard cubic centimeters per minute (sccm)) was further deposited onto tungsten carbide (WC) cutting tools for cylindrical turning experiments. A quasi-constant flank wear was observed until a machining volume of 23,500 mm³. KW - Ti-Al-N coatings KW - DC magnetron sputtering KW - XPS KW - AFM KW - nitrogen flow rate KW - surface morphology Y1 - 2017 UR - http://www.mdpi.com/2075-4701/7/2/52/htm U6 - https://doi.org/10.3390/met7020052 SN - 2075-4701 VL - 7 IS - 2 SP - 52 ER - TY - CHAP A1 - Schulze, Marcus A1 - Seidlitz, Holger A1 - König, Franziska A1 - Weiß, Sabine ED - Dobrzański, Leszek A. T1 - Nanoindentation measurements of PVD coated multilayer constructions T2 - Programme and proceedings of the 22nd Winter International Scintific Conference on Achivements in Mechanical and Materials Engineering (AMME'15), Gliwice - Zakopane (Poland), 2015 Y1 - 2015 SN - 978-83-63553-39-5 PB - Gliwice CY - International OCSCO World Press ER - TY - GEN A1 - Obrosov, Aleksei A1 - Sutygina, Alina A1 - Volinsky, Alex A. A1 - Manakhov, Anton A1 - Weiß, Sabine A1 - Kashkarov, Egor B. T1 - Effect of Hydrogen Exposure on Mechanical and Tribological Behavior of CrₓN Coatings Deposited at Different Pressures on IN718 T2 - Materials N2 - In the current study, the properties of the CrₓN coatings deposited on the Inconel 718 superalloy using direct current reactive magnetron sputtering are investigated. The influence of working pressure on the microstructure, mechanical, and tribological properties of the CrₓN coatings before and after high-temperature hydrogen exposure is studied. The cross-sectional scanning electron micrographs indicate the columnar structure of the coatings, which changes from dense and compact columns to large columns with increasing working pressure. The Cr/N ratio increases from 1.4 to 1.9 with increasing working pressure from 300 to 900 mPa, respectively. X-ray diffraction analysis reveals a change from mixed hcp-Cr₂N and fcc-CrN structure to approximately stoichiometric Cr₂N phase. After gas-phase hydrogenation, the coating deposited at 300 mPa exhibits the lowest hydrogen absorption at 600 °C of all investigated coatings. The results indicate that the dense mixed cubic and hexagonal structure is preferential for hydrogen permeation resistance due to the presence of cubic phase with higher packing density in comparison to the hexagonal structure. After hydrogenation, no changes in phase composition were observed; however, a small amount of hydrogen is accumulated in the coatings. An increase of coating hardness and elastic modulus was observed after hydrogen exposure. Tribological tests reveal that hydrogenation leads to a decrease of the friction coefficient up to 20%–30%. The best value of 0.25 was reached for hydrogen exposed CrₓN coating deposited at 300 mPa. KW - CrₓN coatings KW - PVD KW - hydrogenation KW - tribology KW - mechanical properties KW - GDOES Y1 - 2017 UR - http://www.mdpi.com/1996-1944/10/5/563/htm U6 - https://doi.org/10.3390/ma10050563 SN - 1996-1944 VL - 10 IS - 5 SP - 563 ER - TY - CHAP A1 - Obrosov, Aleksei A1 - Kashkarov, Egor B. A1 - Weiß, Sabine A1 - Volinsky, Alex A. ED - Tiwari, Ashutosh T1 - Mechanical and tribological behaviour of hydrogenated CrxN coatings deposited at different pressure and voltages on IN718 T2 - American Advanced Materials Congress 2016 N2 - Hydrogen degradation is a serious problem in industrial applications like power plants (boilers, turbines), marine structures, car and aircraft components, as it leads to failures as well as to deterioration of properties. Inconel 718 is one of the most commonly used materials for these applications. Different metal nitrides like TiN coatings have been deposited in past to prevent hydrogen degradation, which are also known for their high hardness and good wear resistance [1, 2]. However, reports on hydrogen degradation of CrN coatings, which shows better oxidation and corrosion resistance, higher temperature stability and lower friction coefficient than TiN [3, 4] has not been reported till now. Despite a lot of publications about CrN films, up to now the effect of hydrogenation on mechanical and tribological properties of CrN coatings is still not completely understood. In the current work CrxN coatings were deposited by Direct Current Magnetron Sputtering (dcMS) on Inconel 718 substrate at different chamber pressures and substrate voltages. Substrate voltage is one of the most important process parameters which determines the structure of the coating and the adhesion between substrate and coating. Simultaneously a study of the chamber pressure is also needed to understand the deposited structure and growth rate because at higher pressures the high number of argon atoms reduce the number of ionized ions available for the deposition leading to low deposition rates [5]. Gas-phase hydrogenation of the samples was performed at a temperature of 600° C and hydrogen pressure of 2 atm. It was found that CrxN coatings are resistant against hydrogen exposure as compared to uncoated surfaces. The results of changes in the mechanical, tribological properties and phase composition of the coatings after hydrogenation are discussed. Coating microstructure was studied by scanning electron microscopy (SEM). The mechanical properties of the coatings were characterized by means of nanoindentation and scratch test. KW - CrxN coating KW - mechanical properties KW - microstructure KW - hydrogenation KW - XRD Y1 - 2016 SN - 978-91-88252-03-6 PB - VBRI Press CY - Linköping ER - TY - GEN A1 - Obrosov, Aleksei A1 - Naveed, Muhammad A1 - Krupp, Ulrich A1 - Solovev, Mikhail A1 - Weiß, Sabine T1 - Investigation of TiAlN HiPIMS coating deposited on the newly developed Ni-based superalloy AD730 N2 - The development of new alloys for gas turbine engines has been focused on withstanding against increasing service temperatures. AD730™ is a recently developed nickel-based superalloy for turbine disk applications with superior properties at 700°C, which is higher than the common service temperature for IN718. Use of coatings to enhance the properties of materials, such as wear resistance is widely known in various applications. This research presents an experimental study of TiAlN coatings, deposited onto AD730 superalloy using High Power Impulse Magnetron Sputtering (HiPIMS). Phase structure and chemical composition of the TiAlN films were characterized by X-ray diffractometry. Transmission electron microscopy as well as scanning electron microscopy were used to analyze the microstructure of the coating. Mechanical properties, including hardness, Young's modulus, and adhesion strength were measured using nanoindentation und scratch test. KW - TiAlN coating KW - HiPIMS KW - Ni-based superalloy KW - AD730 TEM XRD Y1 - 2016 UR - http://www.pse-conferences.net/poster-wednesday.html UR - http://www.pse-conferences.net/tl_files/abstract-print/PSE2016-PO3023.pdf N1 - 16th International Conference on Plasma Surface Engineering ER - TY - GEN A1 - Obrosov, Aleksei A1 - Naveed, Muhammad A1 - Weiß, Sabine T1 - Effect of pulse time on structure and mechanical properties of HPPMS deposited AlTiN coatings N2 - The use of PVD AlTiN as a protective coating on cutting tools is well known. With the introduction of pulsed deposition techniques like High Power Pulsed Sputtering (HPPMS), a possibility is provided to the coating developers to design their coatings by the variation in pulse parameters. To analyze the effect of pulse time HPPMS AlTiN coatings were deposited on Si (100) as well as 100Cr6 steel plates at a temperature of 500°C in a reactive gas environment. Oscilloscope measurements depicted a change in current-voltage characteristics with variation in pulse time. This influence the coating structure, deposition rates and phase formations as well. Nanoindentation results show a variation in the mechanical properties of the coatings with the change in pulse time. This study focuses on the potential of HPPMS technology for enhancement of mechanical and structural properties of AlTiN coating. KW - HPPMS KW - AlTiN KW - wear KW - cutting tools KW - pulse time Y1 - 2016 UR - http://www.pse-conferences.net/poster-wednesday.html UR - http://www.pse-conferences.net/tl_files/abstract-print/PSE2016-PO3055.pdf N1 - 16th International Conference on Plasma Surface Engineering ER - TY - CHAP A1 - Bambach, Markus A1 - Sizova, Irina A1 - Bolz, Sebastian A1 - Weiß, Sabine T1 - Development of a dynamic recrystallization model for a β-solidifying titanium aluminide alloy using Kocks-Mecking plots T2 - ESAFORM 2016, proceedings of the 19th International ESAFORM Conference on Material Forming, Nantes, France, 27-29 April 2016 Y1 - 2016 SN - 978-0-7354-1427-3 U6 - https://doi.org/10.1063/1.4963545 SP - 160002-1 EP - 160002-7 PB - AIP Publishing CY - Melville, New York ER - TY - GEN A1 - Kashkarov, Egor B. A1 - Nikitenkov, Nikolay A1 - Sutygina, Alina A1 - Laptev, Roman A1 - Bordulev, Yuriy A1 - Obrosov, Aleksei A1 - Liedke, Maciej O. A1 - Zak, Andrzej A1 - Weiß, Sabine T1 - Microstructure, defect structure and hydrogen trapping in zirconium alloy Zr-1Nb treated by plasma immersion Ti ion implantation and deposition T2 - Journal of Alloys and Compounds N2 - The effect of low energy plasma immersion ion implantation and deposition of titanium on microstructure, defect structure and hydrogen trapping in zirconium alloy Zr-1Nb was studied. Defect structure and distribution were analyzed by Doppler broadening using slow positron beam. The surface microstructure after modification is represented by nanostructured Ti grains with random orientation. The gradient distribution of titanium as well as vacancy type defects were analyzed. The concentration of vacancy type defects is rising with increasing bias voltage. Gas-phase hydrogenation of the Ti-modified Zr-1Nb alloy was performed at 400 °C for 60 min. The strong interaction of hydrogen with vacancy type defects was demonstrated. Two different changes in the defect structure after hydrogenation were observed: when a titanium film is formed on the surface (after deposition at 500 V) hydrogen trapping occurs with the formation of titanium hydride phases, while in the implanted layer (deposition at 1000 and 1500 V) hydrogen is trapped due to interaction with vacancy type defects. The physical basis of Ti diffusion and its influence on the evolution of defect structure after surface modification and hydrogenation were discussed. KW - Zirconium KW - Ion implantation KW - Titanium KW - Diffusion KW - Surface modification KW - Hydrogen trapping KW - Microstructure KW - Slow positrons KW - Doppler broadening KW - Defects Y1 - 2018 UR - http://www.sciencedirect.com/science/article/pii/S0925838817335879 U6 - https://doi.org/10.1016/j.jallcom.2017.10.151 SN - 0925-8388 VL - 732 SP - 80 EP - 87 ER - TY - GEN A1 - Shulepov, Ivan A. A1 - Kashkarov, Egor B. A1 - Stepanov, Igor B. A1 - Syrtanov, Maxim S. A1 - Sutygina, Alina A1 - Shanenkov, Ivan A1 - Obrosov, Aleksei A1 - Weiß, Sabine T1 - The Formation of Composite Ti-Al-N Coatings Using Filtered Vacuum Arc Deposition with Separate Cathodes T2 - Metals N2 - Ti-Al-N coatings were deposited on high-speed steel substrates by filtered vacuum arc deposition (FVAD) during evaporation of aluminum and titanium cathodes. Distribution of elements, phase composition, and mechanical properties of Ti-Al-N coatings were investigated using Auger electron spectroscopy (AES), X-ray diffraction (XRD), transmission electron microscopy (TEM) and nanoindentation, respectively. Additionally, tribological tests and scratch tests of the coatings were performed. The stoichiometry of the coating changes from Ti0.6Al0.4N to Ti0.48Al0.52N with increasing aluminum arc current from 70 A to 90 A, respectively. XRD and TEM showed only face-centered cubic Ti-Al-N phase with preferred orientation of the crystallites in (220) direction with respect to the sample normal and without precipitates of AlN or intermetallics inside the coatings. Incorporation of Al into the TiN lattice caused shifting of the (220) reflex to a higher 2θ angle with increasing Al content. Low content and size of microdroplets were obtained using coaxial plasma filters, which provides good mechanical and tribological properties of the coatings. The highest value of microhardness (36 GPa) and the best wear-resistance were achieved for the coating with higher Al content, thus for Ti0.48Al0.52N. These coatings exhibit good adhesive properties up to 30 N load in the scratch tests. KW - filtered vacuum arc KW - deposition KW - TiAlN KW - separate cathodes KW - phase composition KW - hardness KW - wear-resistance Y1 - 2017 UR - http://www.mdpi.com/2075-4701/7/11/497/htm U6 - https://doi.org/10.3390/met7110497 SN - 2075-4701 VL - 7 IS - 11 ER - TY - GEN A1 - Severin, Stefanie A1 - Naveed, Muhammad A1 - Weiß, Sabine T1 - Effect of HPPMS pulse-frequency on plasma discharge and deposited AlTiN coating properties T2 - Advances in Materials Science and Engineering N2 - Coatings like TiAlN (titanium content more than 50 %) or AlTiN (aluminium content more than 50 %) are well established as hard and wear resistant tool coatings, often prepared by physical vapour deposition (PVD) like arc evaporation or direct current magnetron sputtering (dcMS). With increasing challenges of operating conditions, a constant need in improvement of mechanical properties is required to withstand extreme loading conditions. This can be obtained by a higher amount of ionized sputtered metal atoms during the deposition process. To increase the metal-ion flux a high-power pulse magnetron sputtering (HPPMS) was developed. In order to understand the relation between HPPMS process parameters and mechanical properties of the AlTiN coatings, the present study discusses how different pulse frequencies (for a constant pulse length) influence AlTiN coating structure growth and their mechanical properties. In addition, film deposition rate and phase formation are influenced by altering process parameters like pulse length and frequency. Hence, different pulse-frequencies produce specific coatings with corresponding properties for functional requirements. Based on the established findings, answers to new scientific queries along with the demand to further optimize these coatings for tool applications are required. KW - High power pulsed magnetron sputtering KW - Pulse frequency KW - Nanostructured AlTiN coatings KW - Mechanical properties Y1 - 2017 SN - 1687-8442 VL - 2017 ER - TY - GEN A1 - Doncheva Bambach, Margarita A1 - Bambach, Markus A1 - Sviridov, Alexander A1 - Weiß, Sabine T1 - New process chains involving additive manufacturing and metal forming - a chance for saving energy? T2 - Procedia Engineering KW - additive manufacturing KW - laser deposition welding KW - aluminium KW - energy consumption Y1 - 2017 U6 - https://doi.org/10.1016/j.proeng.2017.10.1049 SN - 1877-7058 N1 - International Conference on the Technology of Plasticity, ICTP 2017, 17-22 September 2017, Cambridge, United Kingdom VL - 207 SP - 1176 EP - 1181 ER - TY - GEN A1 - Obrosov, Aleksei A1 - Sutygina, Alina A1 - Manakhov, Anton A1 - Bolz, Sebastian A1 - Weiß, Sabine A1 - Kashkarov, Egor B. T1 - Oxidation Behavior of Zr–1Nb Corroded in Air at 400 °C after Plasma Immersion Titanium Implantation T2 - Metals N2 - In this paper, the influence of plasma immersion titanium implantation into the zirconium alloy Zr-1Nb on the oxidation behavior at 400 °C for 5, 24, 72, and 240 h in air under normal atmospheric pressure (101.3 kPa) was shown. The influence of implantation on the protective properties of the modified layer was shown. The valence of the oxides before and after implantation was analyzed by means of X-ray photoelectron spectroscopy (XPS). Grazing incidence X-ray diffraction (GIXRD) was carried out to examine the phase composition after titanium ion implantation and oxidation. Differential scanning calorimetry (DSC) revealed that titanium implantation exhibited effects of stabilizing the β phase. The formation of the t-ZrO2 and m-ZrO2 was observed during the oxidation of the as-received and modified Zr-1Nb. The measurement of weight gain showed an improvement in oxidation resistance of Ti implanted Zr-1Nb at the oxidation up to 24 h when compared with that of the as-received Zr-1Nb. However, at longer oxidation cycle the oxidation rate of Ti-implanted zirconium alloy is the same with the as-received alloy, which attributed to the layer thickness. Nevertheless, the corrosion of the Ti-implanted alloy is more uniform, while a local corrosion and cracks was detected on the surface of the as-received alloy. KW - zirconium alloy KW - titanium KW - ion implantation KW - PIII KW - oxidation KW - DSC KW - XPS KW - surface morphology KW - X-ray diffraction Y1 - 2018 UR - http://www.mdpi.com/2075-4701/8/1/27/htm U6 - https://doi.org/10.3390/met8010027 SN - 2075-4701 VL - 8 IS - 1 ER - TY - GEN A1 - Kashkarov, Egor B. A1 - Nikitenkov, Nikolay A1 - Sutygina, Alina A1 - Obrosov, Aleksei A1 - Manakhov, Anton A1 - Polčak, Josef A1 - Weiß, Sabine T1 - Hydrogen absorption by Ti-implanted Zr-1Nb alloy T2 - International journal of hydrogen energy N2 - This paper describes the hydrogenation behavior of Zr-1Nb alloy Ti-implanted by plasma immersion ion implantation (PIII). Hydrogen sorption kinetics of the Ti-modified alloy was investigated under gas-phase hydrogenation at 400 °C for 1 h. The influence of implantation time on the protective properties of the modified layer was shown. The lowest hydrogen absorption as well as the highest hydrogen trapping efficiency was achieved after PIII for 30 min. The main contribution to the reduction of hydrogen permeation is the formation of an oxide layer consisting of mixed TiO2 and ZrO2 on the modified surface of the alloy. X-ray photoelectron spectroscopy (XPS) revealed that PIII titanium oxide exists on the surface in the form of TiO2, which transforms to mixed Ti2O3 and TiO2 after hydrogenation. The thickness of the modified layer increases with implantation time that improves the efficiency of hydrogen trapping. All the absorbed hydrogen is gradually distributed in the modified layer and no hydrides are formed after hydrogenation in Ti-modified Zr-1Nb for 15 and 30 min. KW - Zirconium KW - Titanium implantation KW - Hydrogenation KW - X-ray photoelectron spectroscopy KW - Glow discharge optical emission spectroscopy KW - X-ray diffraction Y1 - 2018 UR - https://www.sciencedirect.com/science/article/pii/S0360319917346359 U6 - https://doi.org/10.1016/j.ijhydene.2017.12.003 SN - 0360-3199 VL - 43 IS - 4 SP - 2484 EP - 2491 ER - TY - GEN A1 - Kashkarov, Egor B. A1 - Obrosov, Aleksei A1 - Sutygina, Alina A1 - Uludintceva, Elena A1 - Mitrofanov, Andrei A1 - Weiß, Sabine T1 - Hydrogen Permeation, and Mechanical and Tribological Behavior, of CrNx Coatings Deposited at Various Bias Voltages on IN718 by Direct Current Reactive Sputtering T2 - Coatings N2 - In the current work, the microstructure, hydrogen permeability, and properties of chromium nitride (CrNₓ) thin films deposited on the Inconel 718 superalloy using direct current reactive sputtering are investigated. The influence of the substrate bias voltage on the crystal structure, mechanical, and tribological properties before and after hydrogen exposure was studied. It was found that increasing the substrate bias voltage leads to densification of the coating. X-ray diffraction (XRD) results reveal a change from mixed fcc-CrN + hcp-Cr₂N to the approximately stoichiometric hcp-Cr₂N phase with increasing substrate bias confirmed by wavelength-dispersive X-ray spectroscopy (WDS). The texture coefficients of (113), (110), and (111) planes vary significantly with increasing substrate bias voltage. The hydrogen permeability was measured by gas-phase hydrogenation. The CrN coating deposited at 60 V with mixed c-CrN and (113) textured hcp-Cr₂N phases exhibits the lowest hydrogen absorption at 873 K. It is suggested that the crystal orientation is only one parameter influencing the permeation resistance of the CrNx coating together with the film structure, the presence of mixing phases, and the packing density of the structure. After hydrogenation, the hardness increased for all coatings, which could be related to the formation of a Cr₂O₃ oxide film on the surface, as well as the defect formation after hydrogen loading. Tribological tests reveal that hydrogenation leads to a decrease of the friction coefficient by up to 40%. The lowest value of 0.25 ± 0.02 was reached for the CrNₓ coating deposited at 60 V after hydrogenation. KW - CrNx coatings KW - Physical Vapour Deposition (PVD) KW - hydrogenation KW - tribology KW - mechanical properties KW - X-ray diffraction Y1 - 2018 UR - http://www.mdpi.com/2079-6412/8/2/66/htm U6 - https://doi.org/10.3390/coatings8020066 SN - 2079-6412 N1 - Special Issue "Surface Preparation and Treatments for Enhancing the Coating Performance" VL - 8 IS - 2 ER - TY - GEN A1 - Evdokimov, Anton A1 - Obrosov, Aleksei A1 - Ossenbrink, Ralf A1 - Weiß, Sabine A1 - Michailov, Vesselin T1 - Mechanical properties of dissimilar steel-aluminum weld T2 - Materials Science and Engineering: A N2 - Knowledge of the properties of dissimilar welds is of great significance for the development of multi-material lightweight structures. In this study, stainless steel (1.4301) and aluminum alloy (6082-T6) sheets were welded in overlap configuration in keyhole mode. The resulting weld metals were investigated with respect to their mechanical properties. Several samples were cut out of different locations along the welds and their cross-sections were subjected to indentation testing and energy dispersive X-ray (EDS) analysis. Young's modulus E, yield stress σy, and strain hardening exponent n, were determined by means of reverse analysis of the indentation load (P) – depth (h) curves, allowing construction of true stress – true strain relations. An essential increase in yield stress in comparison to the one of the base alloys was observed inside the weld metal. In contrary, Young's modulus and strain hardening exponent of the welds were almost identical to corresponding values of the base steel metal. Due to the sensitivity of yield stress to the aluminum content, slight variations of the welding parameters lead to significant changes in elastic-plastic behavior of the weld metal. KW - Mechanical properties KW - Indentation KW - Reverse analysis KW - EDS measurements KW - Dissimilar steel aluminum welding KW - FEM Y1 - 2018 UR - https://www.sciencedirect.com/science/article/pii/S0921509318303563 U6 - https://doi.org/https://doi.org/10.1016/j.msea.2018.03.019 SN - 0921-5093 VL - Volume 722 SP - 242 EP - 254 ER - TY - GEN A1 - Obrosov, Aleksei A1 - Sutygina, Alina A1 - Kashkarov, Egor B. A1 - Weiß, Sabine T1 - Oxidation behavior of Zr–1Nb in air at 400°C after Titanium Plasma Immersion Ion Implantation N2 - Zirconium alloys have been widely used in nuclear reactors due to low thermal neutron capture cross-section, excellent corrosion resistance and acceptable mechanical properties [1, 2]. Nowadays several methods apply for improving hydrogen and corrosion resistance such as addition of stabilizing additives (yttrium) [3, 4], deposition of thin solid films [5, 6], micro-arc oxidation [7] and modification of the surface by electron beam [8, 9]. Despite the multiplicity of the methods hydrogen embrittlement is still a pressing issue. Previous results [10, 11] have shown the positive influence of plasma immersion titanium implantation on the hydrogenation behavior of Zr–1Nb and Zr–2.5 Nb. After Ti implantation hydrogen preferably accumulates in the modified surface layer comprising the implanted Ti. Furthermore, the hydrogen concentration is considerably less inside the zirconium modified sample than in the as-received samples. The integration of elements into the zirconium lattice can influence the valence of the surface and change corrosion and oxidation rates of the alloys. So it is very important not to decrease the zirconium oxidation resistance due to Ti implantation. Therefore, the purpose of this research is to study of the influence of Ti implantation on surface morphology, oxidation rate and phase structure of the Zr–1Nb alloy after oxidation on air at 400 0C for 5, 24, 72 and 240 h. The surface structure of the samples and their elemental composition were investigated with the scanning electron microscope Mira II XMH (Tescan) with energy dispersive x-ray spectroscopy system (EDS). X-ray photoelectron spectroscopy (XPS), differential scanning calorimetry (DSC) as well as X-ray diffraction (XRD) was used to characterise the influence of titanium implantation on the oxidation behaviour. The results show that the oxidation kinetics after Ti modification of the zirconium alloy changed. Although the weight gain of the implanted sample remains approximately the same, it can be considered that Ti implantation stabilizes the oxide layer and has beneficial influence on the oxidation protection of Zr-1Nb. KW - Zr–1Nb KW - titanium ion implantation KW - oxidation KW - DSC KW - plasma immersion ion implantation (PIII) Y1 - 2018 UR - https://www.pse-conferences.net/tl_files/abstract-print/PSE2018-PO4029.pdf ER - TY - GEN A1 - Abang, Roger Atini A1 - Weiß, Sabine A1 - Krautz, Hans Joachim T1 - Impact of increased power plant cycling on the oxidation and corrosion of coal-fired superheater materials T2 - Fuel N2 - As power generation from variable renewable energy sources such as wind and solar power continues to increase in the future, fewer baseload power plants will be needed. As a result, high operational flexibility is becoming a vital requirement for conventional power plants to allow for the smooth integration of the variable renewable energy sources (v-RES) into the grid. To understand the impact of high operational flexibility (increased cycling) for coal-fired power plant materials, five commercial coal boiler superheater and reheater materials were investigated under isothermal and cyclic conditions for 1000 h each. The candidate alloys investigated were: T91, VM12-SHC, TP347-HFG, DMV304 HCu and DMV310 N. The results (weight change kinetics and metallographic analysis) after exposure at a metal surface temperature of 650 °C clearly showed the impact of increased flexibility on the corrosion and oxidation of the materials. Oxide growth (weight gain), metal loss, oxide spallation, and grain boundary attack were found to be more severe under cyclic conditions than under isothermal conditions. KW - Power plant flexibility, Isothermal oxidation, Cyclic oxidation, High temperature corrosion, Superheaters Y1 - 2018 U6 - https://doi.org/10.1016/j.fuel.2018.02.047 SN - 0016-2361 VL - 2018 IS - 220 SP - 521 EP - 534 ER - TY - GEN A1 - Santhanakrishnan Balakrishnan, Venkateswaran A1 - Seidlitz, Holger A1 - Weiß, Sabine T1 - Layup Configuration Effect on Notch Residual Strength in Composite Laminates T2 - Materials N2 - The current trend shows an increasing demand for composites due to their high stiffness to weight ratio and the recent progress in manufacturing and cost reduction of composites. To combine high strength and stiffness in a cost-effective way, composites are often joined with steel or aluminum. However, joining of thermoset composite materials is challenging because circular holes are often used to join them with their metal counterparts. These design based circular holes induce high stress concentration around the hole. The purpose of this paper is to focus on layup configuration and its impact on notch stress distribution. To ensure high quality and uniformity, the holes were machined by a 5 kW continuous wave (cw) CO2 laser. The stress distribution was evaluated and compared by using finite element analysis and Lekhnitskii’s equations. For further understanding, the notch strength of the laminates was compared and strain distributions were analyzed using the digital image correlation technique. KW - composite KW - notch stress KW - digital image correlation KW - ekhnitskii’s equation Y1 - 2018 U6 - https://doi.org/10.3390/ma11020308 SN - 1996-1944 VL - 11 IS - 2 ER - TY - GEN A1 - Kashkarov, Egor B. A1 - Ryabchikov, Alexander I. A1 - Kurochkin, Alexander A1 - Syrtanov, Maxim S. A1 - Shevelev, Alexey A1 - Obrosov, Aleksei A1 - Weiß, Sabine T1 - Hydrogen Interaction with Deep Surface Modified Zr-1Nb Alloy by High Intensity Ti Ion Implantation T2 - Metals N2 - A deep surface modified TiZr layer was fabricated by high-intensity low-energy titanium ion implantation into zirconium alloy Zr-1Nb. Gas-phase hydrogenation was performed to evaluate protective properties of the modified layer against hydrogen permeation into Zr-1Nb alloy. The effects of ion implantation and hydrogen on microstructure, phase composition and elemental distribution of TiZr layer were analyzed by scanning electron microscopy, X-ray diffraction, and glow-discharge optical emission spectroscopy, respectively. It was revealed that TiZr layer (~10 μm thickness) is represented by α′ + α(TiZr) lamellar microstructure with gradient distribution of Ti through the layer depth. It was shown that the formation of TiZr layer provides significant reduction of hydrogen uptake by zirconium alloy at 400 and 500 °C. Hydrogenation of the modified layer leads to refinement of lamellar plates and formation of more homogenous microstructure. Hydrogen desorption from Ti-implanted Zr-1Nb alloy was analyzed by thermal desorption spectroscopy. Hydrogen interaction with the surface modified TiZr layer, as well as its resistance properties, are discussed. KW - zirconium alloy KW - titanium KW - low energy ion implantation KW - hydrogen KW - sorption KW - microstructure KW - morphology KW - martensitic phase Y1 - 2018 UR - https://www.mdpi.com/2075-4701/8/12/1081/htm U6 - https://doi.org/10.3390/met8121081 SN - 2075-4701 VL - 8 IS - 12 ER - TY - GEN A1 - Gunther, Victor A1 - Yasenchuk, Yuri A1 - Chekalkin, Timofey A1 - Marchenko, Ekaterina A1 - Gunther, Sergey A1 - Baigonakova, Gulsharat A1 - Hodorenko, Valentina A1 - Kang, Ji-hoon A1 - Weiß, Sabine A1 - Obrosov, Aleksei T1 - Formation of pores and amorphous-nanocrystalline phases in porous TiNi alloys made by self-propagating high-temperature synthesis (SHS) T2 - Advanced Powder Technology N2 - The objective of this study was to examine the mechanism how the surface of porous TiNi compounds produced by SHS method evolves. The prepared samples were investigated using light-microscopy, X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and energy dispersive x-ray spectroscopy (EDS). The results indicated that the surface of all pores is represented by a granular stratum due to dendrite liquation by peritectic crystallization mechanism. The voids of 2–15 μm in size are formed owing to a capillary spreading of the liquid. Reaction gases with dissociated carbon, nitrogen, and oxygen are responsible for heat-and-mass transfer through the forming pores. High pressure-temperature effect of reaction gases on the melt causes the forming voids to coalesce, as well as transfers the peritectic liquid (PL) throughout the open pores catalyzing a distinctive spitted topography. It is through the chemisorption of gasiform nonmetallics by the pore surface melt, where these impurities are chemically bound, that it was formed a massive corrosion-resistant amorphous-nanocrystalline stratified shell deduced as an intermetallic oxycarbonitride layer. KW - Porous TiNi alloys KW - SHS KW - Pore formation KW - Surface structures KW - Heat-and-mass transfer Y1 - 2019 UR - https://www.sciencedirect.com/science/article/pii/S092188311830387X?via%3Dihub U6 - https://doi.org/10.1016/j.apt.2018.12.011 SN - 0921-8831 VL - 30 IS - 4 SP - 673 EP - 680 ER - TY - GEN A1 - Yasenchuk, Yuri A1 - Gunther, Victor A1 - Marchenko, Ekaterina A1 - Chekalkin, Timofey A1 - Baigonakova, Gulsharat A1 - Hodorenko, Valentina A1 - Gunther, Sergey A1 - Kang, Ji-hoon A1 - Weiß, Sabine A1 - Obrosov, Aleksei T1 - Formation of mineral phases in self-propagating high-temperature synthesis (SHS) of porous TiNi alloy T2 - Materials Research Express N2 - The complex structural-phase composition, morphology and elemental composition of surface and nonmetallics in porous TiNi compounds produced by self-propagating high-temperature synthesis (SHS) in a flow reactor in the layer-by-layer combustion mode were analyzed. The samples were investigated using light microscopy (LM), X-ray diffraction (XRD), scanning electron microscopy (SEM), scanning transmission electron microscopy (STEM), and energy dispersive X-ray spectroscopy (EDS). The findings indicate that in addition to the TiNi and Ti2Ni intermetallic constituents, the pore's surface contains numerous Ti4Ni2(O,N,C) nanocrystalline oxycarbonitrides, spinels, polysilicates, and residual amorphous phases. The elemental composition of the surface and crystalline inclusions is investigated by the EDS method. LM, SEM, TEM, and EDS instrumental examination revealed the entire surface comprising a continuous shell of intermetallic superficial bulb-shaped structures, as well as crystalline inclusions of polysilicates and spinels in the intergranular peritectic phase. Prominent morphology was confirmed to appear throughout the pore's surface owing to the interaction of the peritectic liquid (PL) with reaction gases. The epitaxial, nanocrystalline strata of intermetallic oxycarbonitrides were shown to have the intricate nature. Reaction gases chemisorbed by the PL are responsible for the continuous and dense substrate, which ultrafine structure modulates a high corrosion resistance. On the contrary, the sparse and foamy overlay resulted from a convective transfer of the PL by reaction gases facilitates in vivo bio-integration of the alloy. Overall, this sheds light on and may be more indicative of the complex role of superficial strata and nonmetallic crystals in enhanced biocompatibility of the unwrought porous TiNi alloy. KW - Porous TiNi alloys KW - SHS KW - Pore formation KW - Surface structures KW - Reaction gases KW - Amorphous layer Y1 - 2019 UR - https://iopscience.iop.org/article/10.1088/2053-1591/ab01a1 U6 - https://doi.org/10.1088/2053-1591/ab01a1 SN - 2053-1591 VL - 6 IS - 5 ER - TY - GEN A1 - Fellah, Mamoun A1 - Hezil, Naouel A1 - Djellabi, Ridha A1 - Samad, Mohammed Abdul A1 - Touhami, Mohamed Zine A1 - Montagne, Alex A1 - Iost, Alain A1 - Obrosov, Aleksei A1 - Weiß, Sabine T1 - Rapid and enhanced recovery of poly-dispersed nonionic surfactant (TX-100) from organic mediums using dehydrated and rehydrated kaolin T2 - Applied Clay Science N2 - The recovery of surfactants from organic mediums is of great economic and environmental interests in the field of petrochemicals sector. The aim of this study was to recover poly-dispersed nonionic surfactant (TX-100) from organic medium by the use of dehydrated and rehydrated kaolin. It was found that the presence of water after kaolin rehydration decreases considerably the amount of TX-100 adsorption from 28.7 μmol.g−1 onto dehydrated kaolin to 23.4 μmol.g−1 onto rehydrated kaolin. The estimation of the number of statistical layers of water deposited on kaolin was observed to be about 7 to 9. The effect of type of solvents (heptane, cyclohexane and benzene) on the adsorption onto rehydrated kaolin revealed a reduction in the adsorbed quantity; the adsorbed amounts were found to be 28.7 μmol.g−1, 26.7 μmol.g−1 and 24.2 μmol.g−1 in heptane, cycloheptane and benzene phases, respectively. On the other hand, it was observed that a temperature increased from 20 °C to 35 °C and 45 °C negatively affects the adsorption of TX-100 onto dehydrated and/or hydrated kaolin in heptane medium. KW - Adsorption KW - Organic medium KW - Surfactant recovery KW - Dehydrated/rehydrated kaolin KW - Petrochemical pollution Y1 - 2019 U6 - https://doi.org/10.1016/j.clay.2019.05.004 SN - 0169-1317 VL - 177 SP - 43 EP - 50 ER - TY - GEN A1 - Santhanakrishnan Balakrishnan, Venkateswaran A1 - Obrosov, Aleksei A1 - Kuke, Felix A1 - Seidlitz, Holger A1 - Weiß, Sabine T1 - Influence of metal surface preparation on the flexural strength and impact damage behaviour of thermoplastic FRP reinforced metal laminate made by press forming T2 - Composites Part B: Engineering N2 - In this paper the relationship between surface energy and flexural strength of metal laminate made by reinforcing glass fibre reinforced polymer on steel surfaces was investigated. Sand blasting was performed on 22MnB5 steel surface. This steel was stacked together with layers of unidirectional glass/polyamide-6 prepreg, followed by pressing in a hot press. Influenced parameters are pressure, temperature and time. 3D profilometer analysis was used to investigate the roughness profile on the surface of the steel generated by the sand blasting. The surface energy of the steel surface was calculated from a set of contact angles measured by three different liquids. To identify the optimal surface treatment, the variation of surface energy, flexural strength and roughness of the steel surface was determined as function of the surface treatment. Surface roughness (Ra of 1.08 μm), results indicate that increasing surface roughness leads to improvement in flexural modulus. The increase further leads to decrease in flexural modulus. In addition, the influence of surface energy and flexural strength on the impact damage behaviour was investigated too. The results showed that the sample with highest flexural modulus had the lowest impact-induced damage area. KW - Fiber reinforced plastic (FRP) KW - FRP reinforced metal composite KW - Sand blasting surface treatment KW - Surface energy KW - Contact angle Y1 - 2019 UR - https://www.sciencedirect.com/science/article/pii/S135983681930318X U6 - https://doi.org/10.1016/j.compositesb.2019.05.094 SN - 1359-8368 VL - 173 ER - TY - GEN A1 - Fellah, Mamoun A1 - Hezil, Naouel A1 - Samad, Mohammed Abdul A1 - Montagne, Alex A1 - Kosman, Stephania A1 - Megias, Alberto A1 - Iost, Alain A1 - Obrosov, Aleksei A1 - Weiß, Sabine T1 - Biotribocorrosion behaviour of newly developed nanostructured near β-types Titanium based Alloys for Biomedical Applications T2 - nanoMAT2019 – 2nd International Conference on Nanomaterials and Their Applications N2 - The biotribocorrosion behavior of newly developed nanocristalline near β-types Ti-15Nb and Ti-15Mo alloys surfaces, sintered by powder metallurgy and sequentially milled, has been investigated in SBF simulated body fluid (PBS solution) at OCP, an applied potential in the passive region and EIS. Reciprocating sliding tests using a ball-on-plate tribometer under differentes applied loads 3, 7 and 10 N load and anodic potentials were applied to evaluate the effect of applied lad and the effect of Nb and Mo elements on tribocorrosion behaviors of samples. Results showed that, Ti-Nb exhibited better anticorrosive properties than Ti-Mo. Under tribological action the nanostructured both of alloys showed similar friction coefficient, while Ti-Nb present lower tendency to corrosion compared to Ti-Mo. Furthermore, Nb diffusion increased the repassivation rate with respect to Ti-Mo surfaces due to its stable passive film. Due to the high chemical reaction rate in β-type Ti-15Mo alloy as compared to Ti-15Nb. The β- Ti-15Nb showed lower volume loss, lower friction coefficient values and exhibited better corrosion resistance during tribocorrosion tests than Ti-15Mo. Prevailing electrochemical conditions between -1 and 2 V influences the wear accelerated corrosion by increasing it with the applied potential and slightly increases the mechanical wear. Also, wear accelerated corrosion can be predicted by existing models as a function of electrochemical and mechanical parameters of the titanium alloys. However, considering biomedical applications, the β- Ti15 Mo and Ti15Nb alloys may be good candidates with low elastic modulus and without toxic alloying elements. KW - Biotribocorrosion KW - titanium based alloys KW - Biomedical Applications Y1 - 2019 UR - http://nanomat2019.org/wp-content/uploads/2019/04/Book-of-Abstracts-nanomath2019.pdf SP - 170 ER - TY - GEN A1 - Obrosov, Aleksei A1 - Yasenchuk, Yuri A1 - Marchenko, Ekaterina A1 - Gunther, Victor A1 - Radkevich, Andrey A1 - Kokorev, Oleg A1 - Gunther, Sergey A1 - Baigonakova, Gulsharat A1 - Hodorenko, Valentina A1 - Chekalkin, Timofey A1 - Kang, Ji-hoon A1 - Weiß, Sabine T1 - Biocompatibility and Clinical Application of Porous TiNi Alloys Made by Self-Propagating High-Temperature Synthesis (SHS) T2 - Materials N2 - Porous TiNi alloys fabricated by self-propagating high-temperature synthesis (SHS) are biomaterials designed for medical application in substituting tissue lesions and they were clinically deployed more than 30 years ago. The SHS process, as a very fast and economically justified route of powder metallurgy, has distinctive features which impart special attributes to the resultant implant, facilitating its integration in terms of bio-mechanical/chemical compatibility. On the phenomenological level, the fact of high biocompatibility of porous SHS TiNi (PTN) material in vivo has been recognized and is not in dispute presently, but the rationale is somewhat disputable. The features of the SHS TiNi process led to a multifarious intermetallic Ti4Ni2(O,N,C)-based constituents in the amorphous-nanocrystalline superficial layer which entirely conceals the matrix and enhances the corrosion resistance of the unwrought alloy. In the current article, we briefly explore issues of the high biocompatibility level on which additional studies could be carried out, as well as recent progress and key fields of clinical application, yet allowing innovative solutions. KW - porous SHS TiNi KW - biocompatibility KW - rheological similarity KW - corrosion resistance KW - bone substitution Y1 - 2019 UR - https://www.mdpi.com/1996-1944/12/15/2405/htm#B2-materials-12-02405 U6 - https://doi.org/10.3390/ma12152405 SN - 1996-1944 VL - 12 IS - 15 ER - TY - GEN A1 - Bouaksa, Fethia A1 - Fellah, Mamoun A1 - Hezil, Naouel A1 - Djellabi, Ridha A1 - Touhami, Mohamed Zine A1 - Iost, Alain A1 - Montagne, Alex A1 - Kosman, Stephania A1 - Weiß, Sabine T1 - Effect of Thermocyclic Treatment with Different Cooling Rates on the Mechanical Characteristics of 42CD4 Low-Alloy Steel T2 - Defect and Diffusion Forum N2 - The aim of this study was to investigate the influence of thermo-cyclic treatments on the mechanical characteristics (Hardness and Resilience) of low-alloy 42CD4 steel. Thermocyclic treatment on 42CD4 steel was operated for four cycles at 850 °C for 30 min. After each cycle, the steel sample was cooled in different medium (open air and water) in order to check the effect of the cooling rate on the microstructure characteristics. It was found that the cooling rate can affect the mechanical characteristics of the steel. The hardness values of steel cooled in water were higher than those of steel cooled in air. Additionally, there was an increase in the resilience of steel sample with the increase of thermocyclic number. KW - Austenization KW - Grain Refinement KW - Grain Size KW - Hardness KW - Resilience KW - Thermocyclic Y1 - 2019 UR - https://www.scientific.net/DDF.397.169 U6 - https://doi.org/10.4028/www.scientific.net/DDF.397.169 SN - 1662-9507 VL - 397 SP - 169 EP - 178 ER - TY - GEN A1 - Fellah, Mamoun A1 - Hezil, Naouel A1 - Samad, Mohammed Abdul A1 - Djellabi, Ridha A1 - Montagne, Alex A1 - Mejias, Alberto A1 - Kossman, Stephania A1 - Iost, Alain A1 - Purnama, Agung A1 - Obrosov, Aleksei A1 - Weiß, Sabine T1 - Effect of Molybdenum Content on Structural, Mechanical, and Tribological Properties of Hot Isostatically Pressed β-Type Titanium Alloys for Orthopedic Applications T2 - Journal of Materials Engineering and Performance N2 - Aiming to develop alloys with better properties for orthopedic applications, the focus of the present research was to evaluate the effect of Mo at.% content on structural, mechanical, and tribological properties of hot isostatically pressed Ti-xMo (x = 4, 8, 12, 15, and 20 at.%) alloys. The structural evolution, mechanical properties, and tribological behavior of the nanostructured Ti-xMo alloys were evaluated using x-ray diffraction, scanning electron microscope, and ball-on-disk tribometer. Wear tests were conducted under different applied loads of 2, 8, and 16 N. Experimental results indicated that the structural evolution and morphological changes of the milled alloys were sensitive to their molybdenum (Mo) content. The morphological characterization showed that the crystallite size and the particle size decreased with increasing Mo content (at.%) reaching the lowest values of 27 and 26 nm in the case of Ti-15Mo and Ti-20Mo, respectively. On the other hand, the coefficient of friction and wear rates were found to be decreasing with increasing Mo content. KW - friction behavior KW - hot isostatic pressing KW - milling KW - nanobiomaterials KW - Ti-Mo alloy KW - β-type titanium alloy KW - tribology KW - wear resistance Y1 - 2019 UR - https://link.springer.com/article/10.1007/s11665-019-04348-w U6 - https://doi.org/10.1007/s11665-019-04348-w SN - 1059-9495 VL - 28 IS - 10 SP - 5988 EP - 5999 ER - TY - GEN A1 - Obrosov, Aleksei A1 - Kashkarov, Egor B. A1 - Sharma, A. A1 - Weiß, Sabine T1 - Microstructure and defect structure of Zr-1Nb alloy deep surface modified by high Intensity Ti Ion implantation T2 - MC Microscopy Conference, 01-05 September 2019, Berlin, Abstracts N2 - A deep surface modified TiZr layer was fabricated by high-intensity low-energy titanium ion implantation into zirconium alloy Zr-1Nb alloy with the various dose in the range of (5.4–9.56) × 1020 ion/cm2. The gradient distribution of titanium as well as vacancy type defects were analysed. The effects of ion implantation on microstructure, phase composition and elemental distribution of TiZr layer were analysed by scanning electron microscopy, transmission electron microscopy, X-ray diffraction, and glow-discharge optical emission spectroscopy, respectively. The results show the appearance of Zr-Ti intermetallic phases of different stoichiometry after Ti implantation. The intermetallic phases are transformed from both Zr0.7Ti0.3 and Zr0.5Ti0.5 to single Zr0.6Ti0.4 phase with the increase in the implantation dose. The depth of Ti penetration into the bulk of Zr increases from 6 to 13 μm with the implantation dose. The higher current density (170 mA/cm2) leads to the increase in the grain size and surface roughness. It was revealed that TiZr layer (~10 μm thickness) is represented by α′ + α(TiZr) lamellar microstructure with gradient distribution of Ti through the layer depth. Transmission electron microscopy was used for investigation of the physical basis of Ti diffusion and its influence on the evolution of the defect structure after surface modification. Furthermore, it was found that on the surface between substrate and implanted layer was found an amorphous layer, which occur as a result of further stress accumulations from the higher implantation doses. Y1 - 2019 UR - https://epub.uni-regensburg.de/40685/1/MC%202019_Proceedings.pdf SP - 86 CY - Berlin ER - TY - GEN A1 - Fellah, Mamoun A1 - Hezil, Naouel A1 - Dekhil, Leila A1 - Samad, Mohammed Abdul A1 - Djellabi, Ridha A1 - Kosman, Stephania A1 - Montagne, Alex A1 - Iost, Alain A1 - Obrosov, Aleksei A1 - Weiß, Sabine T1 - Effect of sintering temperature on structure and tribological properties of nanostructured Ti–15Mo alloy for biomedical applications T2 - Transactions of Nonferrous Metals Society of China N2 - The effect of sintering temperature (1073–1373 K) on the structural and tribological properties of nanostructured ball-milled β-type Ti–15Mo samples was investigated. The prepared samples were characterized using various apperatus such as X-ray diffractometer, scanning electron microscope (SEM) and ball-on-plate type oscillating tribometer. Wear tests were conducted under different applied loads (2, 8 and 16 N). Structural results showed that the mean pore and crystallite size continuously decreased with increasing sintering temperature to reach the lowest values of 4 nm and 29 nm at 1373 K, respectively. The relative density of the sintered sample at 1373 K was as high as 97.0%. Moreover, a higher sintering temperature resulted in higher relative density, greater hardness and elastic modulus of the sample. It was observed that both the friction coefficient and wear rate were lower in the sample sintered at 1373 K which was attributed to the closed porosity. KW - Ti–15Mo KW - wear KW - tribological behaviour KW - nanotribology KW - sintering KW - biomedical applications Y1 - 2019 UR - https://www.sciencedirect.com/science/article/pii/S100363261965137X#! U6 - https://doi.org/10.1016/S1003-6326(19)65137-X SN - 1003-6326 VL - 29 IS - 11 SP - 2310 EP - 2320 ER - TY - GEN A1 - Ermilova, Evgeniia A1 - Kazak, Fedor A1 - Weiß, Sabine T1 - Stability of structured sheet metals during buckling T2 - Materials Testing N2 - Structured materials can be a progressive alternative to commonly used flat sheets. There is an enormous range of possibilities for using structured sheet metals due to their better stability. However, the effective use of these materials as well as their implementation in production requires precise knowledge about specific properties of structured sheet metals. The aim of this work is to obtain new knowledge about stiffness and stability during the deformation of this material. The structured sheet metals were investigated by means of buckling tests. The steel type investigated is a commonly used deep-drawing steel DC04. Six types of structure arrangements were compared to non-structured (flat) specimens as a reference. The influence of the type of structure arrangement as well as the deformation speed on the mechanical properties was investigated. KW - Structured metals KW - flat sheet metals KW - buckling test KW - stiffness KW - stability Y1 - 2019 UR - https://www.hanser-elibrary.com/doi/10.3139/120.111403 U6 - https://doi.org/10.3139/120.111403 SN - 2195-8572 SN - 0025-5300 VL - 61 IS - 10 SP - 929 EP - 935 ER - TY - GEN A1 - Fellah, Mamoun A1 - Hezil, Naouel A1 - Dekhil, Leila A1 - Samad, Mohammed Abdul A1 - Montagne, Alex A1 - Mejias, Alberto A1 - Iost, Alain A1 - Obrosov, Aleksei A1 - Weiß, Sabine T1 - Structural characterization of developed near β-Type Titanium Alloys (Ti-25NbxZr) for biomedical Applications T2 - 3rd International Conference on Mechanics and Materials : ICMM’2019 11-12 November 2019. Setif, Algeria, Abstracts book N2 - The osteoarthritis and degenerative diseases osteoporosis as well as trauma lead to the bone mechanical properties degradation due to absence of normal biological self healing processes or excessive loading [1–5]. These problems solution are artificial biomaterials, as surgical implantation of appropriate shapes helps restore function for the otherwise functionally compromised structures [1–5]. Biocompatibility is considered to be optimal once tissue neoformation and later function occurs around implantable devices [6]. The efficacy of biomaterials implants is determined mostly by their surface characteristics such as microstructure, surface morphology, composition and biological properties [2]. Aiming to develop alloys with better properties for orthopedic applications, the focus of the present research was to evaluate the effect of Zr at. % content on structural, mechanical and tribological properties of hot isostatically pressed Ti-25Nb-xZr (x = 5, 10, 15, 20 and 25 at. %) alloys. The structural evolution, and mechanical properties of the nanostructured Ti-Nb-xZr alloys were evaluated using X-Ray diffraction, scanning electron microscope. The mechanical properties were performed using Vickers hardness and berkovich nanoindentation. Experimental results indicated that the structural evolution and morphological changes of the milled alloys were sensitive to their Zirconium (at. %) content. The morphological characterization showed that the crystallite size and the particle size decreased with increasing Zr content (at. %). As well, as the Zr was added to the Ti-25NbXZr system, there was a clear decrease in the Vickers hardness and young’s modulus. On the other hand, the coefficient of friction and wear rates were found to be decreasing with increasing Zr content. KW - Ti-Nb-Zr alloys KW - Nanobiomaterials KW - tribological behaviour KW - Sintering KW - Biomedical applications Y1 - 2019 UR - https://drive.google.com/file/d/1XCFz_8p3aAacxwT1bWgK_rljAL5_oEXS/view SP - 224 EP - 225 CY - Setif, Algeria ER - TY - GEN A1 - Khalil, S. A1 - Fellah, Mamoun A1 - Hezil, Naouel A1 - Smata, L. A1 - Montagne, Alex A1 - Mejias, Alberto A1 - Kossman, Stephania A1 - Iost, Alain A1 - Obrosov, Aleksei A1 - Weiß, Sabine T1 - Synthèse et caractérisation structurale d’un composé nanostructuré de Ti, Mo et Zr pour applications biomédicales T2 - 3rd International Conference on Mechanics and Materials : ICMM’2019 11-12 November 2019. Setif, Algeria, Abstracts book N2 - Le milieu médical est un perpétuel demandeur de biomatériaux compatibles surtout en orthopédie. Effectivement le nombre important d’arthroplasties effectuées chaque année ne cesse d’augmenter dans le monde, non seulement du fait vieillissement de la population (à partir de 65 ans), mais aussi de demandes de patients plus jeunes entre 45 ans et 55 ans. Actuellement, les composés à base de titane Ti sont largement utilisés comme des biomatériaux pour leur biocompatibilité, leur résistance à la corrosion et leur faible module d’élasticité. Le molybdène et le zirconium sont parmi les meilleurs éléments alliés parce qu’ils sont non toxiques et non allergiques et offrent d’excellentes propriétés. De plus,Le Zr peut augmenter la trempabilité et la résistance à la corrosion de l'alliage . Mo est un élément fort stabilisant pour la phase des alliages de titane et les alliages à base de Ti-Mo présentent des propriétés mécaniques adéquates compatibilité et bonne cyto-compatibilité . Par conséquent, le système Ti-Mo-Zr, qui a montré une bonnes performances et de magnifiques perspectives dans l’application de biomatériaux, a été intensivementétudié [1,2,3]. Cependant, les alliages de Ti largement utilisés, tels que les interstitiels extra-low (ELI) Ti-6Al-4V (wt.% en poids ), Ti- 5Al-2,5 Fe et Ti-6Al-7Nb, ont le risque de libérer de l'aluminium toxique (Al) et les Ions de vanadium (V) in vivo, ce qui peut causer des problèmes de santé, comme la maladie d’Alzheimer et la neuropathie[4].La métallurgie des poudres (MP), y compris la méthode de mixture des composants en poudre, qui consiste à fritter titane en poudre ou ses mélanges avec d’autres composants en poudre, est un procédé économique à moindre cout. La nanotechnologie est intervenue dans la structuration des biomatériaux à l’échelle nanométrique (entre1nmet 100 nm) par soucis d’amélioration des propriétés mécanique surtout le module de Young. KW - Biomatériaux, KW - Ti-Mo-Zr KW - nanomatériaux KW - caractérisation structurale KW - broyage mécanique Y1 - 2019 UR - https://drive.google.com/file/d/1XCFz_8p3aAacxwT1bWgK_rljAL5_oEXS/view SP - 243 EP - 244 CY - Setif, Algeria ER - TY - GEN A1 - Shapovalov, Oleg A1 - Gaal, Mate A1 - Hönig, Gerald A1 - Gradt, Thomas A1 - Weiß, Sabine ED - Ochmann, Martin ED - Vorländer, Michael ED - Fels, Janina T1 - Temperature dependence of the propagation speed of a longitudinal wave in different solids for use as a wedge material in an extreme-temperature-resistant ultrasonic transducer T2 - Proceedings of the 23rd International Congress on Acoustics : integrating 4th EAA Euroregio 2019 : 9-13 September 2019 in Aachen, Germany N2 - In special cases of angle beam ultrasonic measurement – e.g. defect detection in hot solids as well as flow measurement of liquid gases or energy storage mediums [1] – the applied transducer has to withstand extreme temperatures. Since the irradiation angle into the specific material is determined not only by wedge design, but also by the speed of sound in both the wedge material and the tested object, the developer must take into account the speed of the wave propagation in a wedge material over the whole temperature range of transducers application. In this study we investigate the temperature dependence of the speed of longitudinal wave propagation in 10 different materials in the range from -200 °C to 400 °C. The investigated materials belong to different material classes (ceramics, glass, as well as ferrous and non-ferrous metals) and are all temperature-resistant up to at least 600 °C, and therefore applicable as wedge materials in an ultrasonic transducer for use at extreme temperatures. KW - Ultrasonic Transducer KW - Speed of sound KW - Longitudinal Wave KW - Temperature Y1 - 2019 UR - http://publications.rwth-aachen.de/record/770364/files/770364.pdf SN - 978-3-939296-15-7 U6 - https://doi.org/10.18154/RWTH-CONV-239953 SN - 2226-7808 SN - 2415-1599 VL - 2019 SP - 4754 EP - 4760 CY - Aachen ER - TY - GEN A1 - Marchenko, Ekaterina A1 - Yasenchuk, Yuri A1 - Gunther, Sergey A1 - Baigonakova, Gulsharat A1 - Gunther, Victor A1 - Chekalkin, Timofey A1 - Weiß, Sabine A1 - Obrosov, Aleksei A1 - Dubovikov, Kirill T1 - Structural-phase surface composition of porous TiNi produced by SHS T2 - Materials Research Express N2 - The study aimed to characterize the structural-phase composition of the porous SHS TiNi surface explored by the GIXRD method. The surface layers at a depth of up to 100 nm mainly consist of amorphous nanocrystalline intermetallic oxycarbonitrides Ti₄Ni₂(O,N,C) with nonmetallic inclusions of different structural variants and routes of origin. Fine-porous alloys were synthesized at ignition temperatures of 450-480 °C. A distinct feature of the surface of crystalline phases therein was shown to be a low degree of crystallinity (up to 40%) and presence of multifarious glass and cermet phases evident as NiSi₂, NaAlSiO (SO₄), SiO₂, MgSi₂, and CaCO₃. Conversely, large-pore alloys ignited at temperatures of 280-330 °C have a higher degree of crystallinity (up to 70%). An individually selected GIXRD technique and precision structural phase analysis are capable to determine a set of other superficial nonmetallic and cermet phases reported as CaTiO₃, Si (P2O₇), CaSiO₃, MgAl₂O₄, TiNiAl, as well as the Ti₃SiC₂MAX phase. Y1 - 2019 UR - https://iopscience.iop.org/article/10.1088/2053-1591/ab4e32/pdf U6 - https://doi.org/10.1088/2053-1591/ab4e32 SN - 2053-1591 VL - 6 IS - 11 ER - TY - GEN A1 - Fellah, Mamoun A1 - Hezil, Naouel A1 - Samad, Mohammed Abdul A1 - Touhami, Mohamed Zine A1 - Montagne, Alex A1 - Iost, Alain A1 - Obrosov, Aleksei A1 - Weiß, Sabine T1 - Preliminary investigation on the bio-tribocorrosion behavior of porous nanostructured β-type titanium based biomedical alloys T2 - Materials Letters N2 - The bio-tribocorrosion behavior of newly developed near β-types Ti-15Nb and Ti-15Mo alloys was investigated in Phosphate-Buffered Saline (PBS) under different loads. Open-Circuit Potential (OCP), friction coefficient, wear volume and wear rate were evaluated. The results revealed that Ti-15Nb alloy exhibited lower wear rate, lower friction coefficient and better corrosion resistance during tribocorrosion than the Ti-15Mo alloy. This can be attributed to the diffusion of Nb which increases the repassivation rate (formation of a protective layer) in the Ti-15Nb alloy. In contrast Ti-15Mo shows a significantly higher rate of chemical reaction. KW - Ti-15Mo KW - Ti-15Nb KW - Corrosion KW - Bio-tribocorrosion KW - Biomaterials Y1 - 2019 UR - https://www.sciencedirect.com/science/article/pii/S0167577X19313862 U6 - https://doi.org/10.1016/j.matlet.2019.126755 SN - 0167-577X VL - 257 ER - TY - GEN A1 - Fellah, Mamoun A1 - Hezil, Naouel A1 - Touhami, Mohamed Zine A1 - Obrosov, Aleksei A1 - Weiß, Sabine A1 - Kashkarov, Egor B. A1 - Lider, Andrey M. A1 - Montagne, Alex A1 - Iost, Alain T1 - Enhanced Structural and Tribological Performance of Nanostructured Ti–15Nb Alloy for Biomedical Applications T2 - Results in Physics N2 - Low modulus β-type Ti-15Nb alloys were prepared by subjecting them to different sintering temperatures (800, 900, 1000 and 1100 °C) and their morphological and structural properties were evaluated. X-ray diffraction analysis was used for the morphological characterization which indicated that the mean pore and crystallite size continuously decreased with increasing sintering temperature to reach the lowest values of 41 nm and 27.5 nm at 1100 °C, respectively. Moreover, the higher sintering temperature resulted in higher relative density, greater hardness and young’s modulus of the Ti-15Nb alloys. Wear tests were conducted using a ball-on-plate type Oscillating tribometer, under different applied loads (2, 8 and 16 N) to evaluate their tribological characterization. The wear rate and friction coefficient were lower at higher sintering temperature. This enhancement in tribological properties was attributed to a grain refinement. The Ti-15Nb alloys sintered at 1100 °C showed the best tribological performance. KW - Tribological properties KW - Sintering KW - Biomaterial KW - β-Ti Alloys KW - Ti-15Nb alloys KW - Milling Y1 - 2019 UR - https://www.sciencedirect.com/science/article/pii/S2211379719300506 U6 - https://doi.org/10.1016/j.rinp.2019.102767 SN - 2211-3797 VL - 15 ER - TY - GEN A1 - Stendal, Johan Andreas A1 - Bambach, Markus A1 - Eisentraut, Mark A1 - Sizova, Irina A1 - Weiß, Sabine T1 - Applying Machine Learning to the Phenomenological Flow Stress Modeling of TNM-B1 T2 - Metals N2 - Data-driven or machine learning approaches are increasingly being used in material science and research. Specifically, machine learning has been implemented in the fields of materials discovery, prediction of phase diagrams and material modelling. In this work, the application of machine learning to the traditional phenomenological flow stress modelling of the titanium aluminide (TiAl) alloy TNM-B1 (Ti-43.5Al-4Nb-1Mo-0.1B) is investigated. Three model types were developed, analyzed and compared; a physics-based phenomenological model (PM) originally developed for steel by Cingara and McQueen, a purely data-driven machine learning model (MLM), and a hybrid model (HM), which uses characteristic points predicted by a learning algorithm as input for the phenomenological model. The same amount of data was used to both fit the PM and train the MLM and HM. The models were analyzed and compared based on the accuracy of their predictions, development and computing time, and their ability to predict on interpolated and extrapolated inputs. The results revealed that for the same amount of experimental data, the MLM was more accurate than the PM. In addition, the MLM was better able to capture the characteristic peak stress in the TNM-B1 the flow curves, and could be developed and computed faster. Furthermore, the MLM was able to make realistic predictions for inputs outside the experimental data used for training. The HM showed comparable accuracy to the PM for the experimental conditions. However, the HM was able to produce a better fit for input conditions outside the training data. KW - machine learning KW - phenomenological modeling KW - titanium aluminide KW - hot isothermal forging Y1 - 2019 UR - https://www.mdpi.com/2075-4701/9/2/220 U6 - https://doi.org/10.3390/met9020220 SN - 2075-4701 VL - 9 IS - 2 ER - TY - GEN A1 - Eisentraut, Mark A1 - Bolz, Sebastian A1 - Sizova, Irina A1 - Bambach, Markus A1 - Weiß, Sabine T1 - Development of a heat treatment strategy for the γ-TiAl based alloy TNM-B1 to increase the hot workability T2 - SN Applied Sciences Y1 - 2019 U6 - https://doi.org/10.1007/s42452-019-1563-4 SN - 2523-3963 SN - 2523-3971 VL - 1 IS - 11 ER - TY - GEN A1 - Stendal, Johan Andreas A1 - Eisentraut, Mark A1 - Sizova, Irina A1 - Bolz, Sebastian A1 - Bambach, Markus A1 - Weiß, Sabine T1 - Effect of heat treatment on the workability of hot isostatically pressed TNM-B1 T2 - AIP Conference Proceedings Y1 - 2019 SN - 978-0-7354-1847-9 U6 - https://doi.org/10.1063/1.5112544 VL - 2113 IS - 1 ER - TY - CHAP A1 - Fellah, Mamoun A1 - Hezil, Naouel A1 - Abderrahim, Karima A1 - Samad, Mohammed Abdul A1 - Montagne, Alex A1 - Mejias, Alberto A1 - Iost, Alain A1 - Kossman, Stephania A1 - Chekalkin, Timofey A1 - Obrosov, Aleksei A1 - Weiß, Sabine T1 - Investigating the Effect of Sintering Temperature on Structural and Tribological Properties of a Nanostructured Ti–20Nb–13Zr Alloy for Biomedical Applications T2 - Characterization of Minerals, Metals, and Materials N2 - β-type Ti–20Nb–13Zr alloys with low Young’s modulus were prepared at different sintering temperatures (950, 1050, 1150, and 1250 °C). The morphological and structural characteristics of as-prepared samples were investigated by several methods. Wear tests were conducted using a ball-on-plate type oscillating tribometer under different applied loads (2, 10, and 20 N). The morphological characterization indicated that the mean pore and crystallite size continuously decreased with increasing sintering temperature to reach lowest values of 40 nm and 38 nm at 1250 °C, respectively. The relative density of the 1250 °C sintered sample was as high as 98.7%. Moreover, the higher sintering temperature resulted in higher relative density and closed porosity of the sample. Both the friction coefficient and wear rate were lower in the sample sintered at 1250 °C as compared to other samples. This enhancement in tribological properties was attributed to a closed porosity. KW - Ti-20Nb-13Zr KW - Nanobiomaterials KW - Tribological behaviour KW - Nanotribology KW - Sintering KW - Biomedical applications Y1 - 2020 SN - 978-3-030-36628-5 SN - 978-3-030-36627-8 U6 - https://doi.org/10.1007/978-3-030-36628-5_61 SN - 2367-1181 SN - 2367-1696 SP - 619 EP - 629 PB - Springer CY - Cham ER - TY - GEN A1 - Fellah, Mamoun A1 - Hezil, Naouel A1 - Touhami, Mohamed Zine A1 - Hussien, Mohammed A. A1 - Montagne, Alex A1 - Mejias, Alberto A1 - Iost, Alain A1 - Kossman, Stephania A1 - Chekalkin, Timofey A1 - Obrosov, Aleksei A1 - Weiß, Sabine T1 - Effect of Sintering Temperature on Mechanical and Tribological Behavior of Ti–Ni Alloy for Biomedical Applications T2 - TMS 2020 149th Annual Meeting & Exhibition Supplemental Proceedings N2 - Ti–Ni powder compacts were prepared by mechanical alloying (MA), followed by hot isostatic pressing (HIP). Afterwards, the samples were sintered at different temperatures (950, 1050, 1150 and 1250 °C). Microhardness, density, crystallite size as well as microstrain of the sintered samples were measured and analyzed. Wear characteristics in phosphate-buffered saline (PBS) solution was tested under different applied loads of 2 N, 10 N, and 20 N, respectively. The results indicated that the crystallite size continuously decreases with increasing sintering temperature and reaches the lowest value of 31.3 nm at 1250 °C. The relative density of the sample sintered at 1250 °C is 98.0%. Moreover, the higher sintering temperatures lead to the higher relative density and the increase in hardness and young’s modulus of the sample. At the same time the friction coefficient and wear rate were lower for the samples sintered at 1250 °C. This improvement in friction and wear resistance is attributed to the grain size refinement. Ti–Ni sintered at 1250 °C showed good tribological performance under all test conditions. KW - Ti–Ni KW - Nanobiomaterials KW - Tribological behaviour KW - Sintering KW - Biomedical applications Y1 - 2020 SN - 978-3-030-36295-9 SN - 978-3-030-36296-6 U6 - https://doi.org/10.1007/978-3-030-36296-6_157 SN - 2367-1181 SN - 2367-1696 SP - 1701 EP - 1710 PB - Springer CY - Cham ER - TY - GEN A1 - Hezil, Naouel A1 - Fellah, Mamoun A1 - Montagne, Alex A1 - Iost, Alain A1 - Obrosov, Aleksei A1 - Weiß, Sabine T1 - Removal of Chromium (VI) from Water onto Activated Carbon by Adsorption in Dynamic Mode T2 - TMS 2020 149th Annual Meeting & Exhibition Supplemental Proceedings N2 - Hexavalent chromium pollution from industrial waste water is a serious problem as it can cause adverse effects on the environment. Several methods are used to reduce the harmful effects of this pollutant, especially physico-chemical methods, such as adsorption technology. The present study aims to remove Cr (VI) from industrial sources in a fixed-bed column of activated carbon. The experiments were carried out at natural pH and temperature with a flow rate (5, 10, and 20 mL/min) and bed height (3.5 cm). Breakthrough curves for feed concentrations (0.01, 0.03, and 0.05 mol/L) were investigated. The results indicated a marked decrease up to 99%. The value of the flow constant for the Thomas model decreased with the increase in the concentration of the incoming substance, but increased with the increase in the flow rate. KW - Hexavalent chromium KW - Activated carbon KW - Adsorption KW - Breakthrough curve KW - Fixed-bed column Y1 - 2020 SN - 978-3-030-36295-9 SN - 978-3-030-36296-6 U6 - https://doi.org/https://doi.org/10.1007/978-3-030-36296-6_80 SN - 2367-1181 SN - 2367-1696 SP - 855 EP - 863 PB - Springer CY - Cham ER - TY - GEN A1 - Evdokimov, Anton A1 - Doynov, Nikolay A1 - Ossenbrink, Ralf A1 - Obrosov, Aleksei A1 - Weiß, Sabine A1 - Michailov, Vesselin T1 - Thermomechanical laser welding simulation of dissimilar steel-aluminum overlap joints T2 - International Journal of Mechanical Sciences N2 - Mixing of steel and aluminum within the weld pool during keyhole laser welding results in a complex dissimilar microstructure, which in turn, initiates a shift in weld metal mechanical properties. In this study, a numerical model for computation of distortions in laser-welded dissimilar overlap joints (austenitic stainless steel 304 – 6082-T6 aluminum alloy), which considers properties of the mixed steel-aluminum weld metal was developed. The required yield strength, Young's modulus, and strain hardening exponent of the weld metal were experimentally determined using the indentation technique coupled with energy-dispersive X-ray spectroscopy. The designed material model calculates the weld elastic-plastic properties as a function of the aluminum concentration. The softening of the alloys in the heat-affected zone was determined by physical simulations and considered as a function of maximum temperature. Computed and measured distortions showed good agreement for various welding regimes with an average deviation of 18.4%. The sensitivity analyses indicated that the application of the developed weld material model significantly improves the accuracy of the thermomechanical simulations. Y1 - 2021 U6 - https://doi.org/10.1016/j.ijmecsci.2020.106019 SN - 1879-2162 VL - 190 ER - TY - GEN A1 - Baigonakova, Gulsharat A1 - Marchenko, Ekaterina A1 - Chekalkin, Timofey A1 - Kang, Ji-hoon A1 - Weiß, Sabine A1 - Obrosov, Aleksei T1 - Influence of Silver Addition on Structure, Martensite Transformations and Mechanical Properties of TiNi–Ag Alloy Wires for Biomedical Application T2 - Materials N2 - The microstructural and functional behavior of TiNi-based wires with a silver content of 0–1.5 at.% was evaluated. The concentration range for Ag doping determined for the TiNi wires with potential for the medical industry was 0–0.2 at.%. Microstructure analysis of TiNi wires with different silver contents at room temperature indicated a multiphase structural state. Various internal structures with tangled grain boundaries were formed by intense plastic deformation. The nanocrystalline structure and phase state of wire with the minimum silver content (0.1 at.% Ag) provide full shape recovery, the greatest reversible strain, and optimal strength and ductility. TiNi ingots with a high Ag content (0.5–1.5 at.%) cracked under minimum load due to excess silver that crystallized along the grain boundaries and broke cohesion bonds between the TiNi grains. KW - shape memory alloy KW - silver KW - doping KW - mechanical properties KW - nanostructured material KW - wire Y1 - 2020 UR - https://www.mdpi.com/1996-1944/13/21/4721 U6 - https://doi.org/10.3390/ma13214721 SN - 1996-1944 VL - 13 IS - 21 ER - TY - GEN A1 - Hazil, Naouel A1 - Fellah, Mamoun A1 - Montagne, Alex A1 - Iost, Alain A1 - Obrosov, Aleksei A1 - Weiß, Sabine T1 - Study of the photocatalytic degradation of Orange methyl dye in the presence of titanium dioxide T2 - La Troisième Conférence Méditerranéenne de la Biodiversité 2019 (BIODIV 2019) N2 - The use of photocatalytic techniques for water purification and wastewater treatment is very widespread, in our work we used TiO2 to photocatalyrate orange methyl (MO). In addition, the effects of some parameters on photodegradation of MO have been studied, such as the presence and / or absence of light (UV). The use of TiO2 showed a high MO degradation efficiency of up to 98%. The presence of H2O2 in the photocatalytic reaction may favor the photocatalytic degradation efficiencies. In addition, the experimental results have demonstrated an excellent rate of the order of 99%. KW - Titanium Dioxide KW - Photocatalytic Degradation Y1 - 2019 UR - http://ascob.net/files/abstract_book_biodiv2019_finale.pdf SP - 105 PB - L’ASCOB-SYRTIS CY - Hammamet, Tunisie ER -