<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>26929</id>
    <completedYear/>
    <publishedYear>2021</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>248</pageFirst>
    <pageLast>259</pageLast>
    <pageNumber/>
    <edition/>
    <issue>1</issue>
    <volume>3</volume>
    <type>articler</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2021-01-28</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Temperature–Pressure Hybrid Sensing All-Organic Stretchable Energy Harvester</title>
    <abstract language="eng">The design and development of intrinsically stretchable all-organic self-powered sensors concurrently perceiving temperature and pressure remain a challenge but deliver an exciting platform to realize environmentally friendly wearable electronics. In this approach, a biomimetic all-organic stretchable energy harvester is designed by a xylitol-added poly(3,4-ethylenedioxythiophene):poly(4-styrenesulfonate) (PEDOT:PSS/Xyl) film as a compatible overlay electrode with polyaniline-reinforced one-dimensional aligned poly(vinylidene fluoride) hybrid electroactive soft nanowires. The gradient of elastic modulus between the electrode and the active nanowire component enables the all-organic device to manifest excellent power-generating performance under external temperature fluctuation (∼3 μW/m2 under ΔT ∼ 92 K) and mechanical force (∼31 μW/cm2 at 30 N). Importantly, the device renders simultaneous energy scavenging of temperature and pressure changes under pressing and stretching conditions (∼20%). The excellent mechanosensitivity (∼100 mV/N), fast response time (∼1 ms), outstanding mechanical and thermal stability, and good temperature resolution &lt;10 K enable the harvester to act as an epidermal sensor, which simultaneously detects and discriminates both subtle pressure and thermal deviations exposed to an epidermis surface. The real-time recording and wireless transferring of physiological signals to a smartphone indicate an effective way to realize remote healthcare monitoring for early intervention.</abstract>
    <parentTitle language="eng">ACS Applied Electronic Materials</parentTitle>
    <identifier type="issn">2637-6113</identifier>
    <identifier type="doi">10.1021/acsaelm.0c00816</identifier>
    <enrichment key="BTU">an der BTU erstellt / created at BTU</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">false</enrichment>
    <enrichment key="Fprofil">1 Energiewende und Dekarbonisierung / Energy Transition and Decarbonisation</enrichment>
    <enrichment key="Fprofil">4 Künstliche Intelligenz und Sensorik / Artificial Intelligence and Sensor Technology</enrichment>
    <author>
      <firstName>Sujoy Kumar</firstName>
      <lastName>Ghosh</lastName>
    </author>
    <submitter>
      <firstName>Karsten</firstName>
      <lastName>Henkel</lastName>
    </submitter>
    <author>
      <firstName>Tridib Kumar</firstName>
      <lastName>Sinha</lastName>
    </author>
    <author>
      <firstName>Mengying</firstName>
      <lastName>Xie</lastName>
    </author>
    <author>
      <firstName>Christopher Rhys</firstName>
      <lastName>Bowen</lastName>
    </author>
    <author>
      <firstName>Samiran</firstName>
      <lastName>Garain</lastName>
    </author>
    <author>
      <firstName>Biswajit</firstName>
      <lastName>Mahanty</lastName>
    </author>
    <author>
      <firstName>Krittish</firstName>
      <lastName>Roy</lastName>
    </author>
    <author>
      <firstName>Karsten</firstName>
      <lastName>Henkel</lastName>
    </author>
    <author>
      <firstName>Dieter</firstName>
      <lastName>Schmeißer</lastName>
    </author>
    <author>
      <firstName>Jin Kuk</firstName>
      <lastName>Kim</lastName>
    </author>
    <author>
      <firstName>Dipankar</firstName>
      <lastName>Mandal</lastName>
    </author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>all-organic</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>piezoelectric</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>pyroelectric</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>energy harvester</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>sensor</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>healthcare monitoring</value>
    </subject>
    <collection role="institutes" number="1503">FG Angewandte Physik und Halbleiterspektroskopie</collection>
  </doc>
</export-example>
