    <title language="eng">Non-Combustible MLI Based Insulation Behavior Under Fire Condition - Experimental and Numerical Investigation</title>
    <abstract language="eng">The number of applications that demand zero-emission energy carriers, such as liquified hydrogen (LH2), is increasing worldwide. LH2 is typically transported or stored under cryogenic conditions. Storage in such conditions requires super thermal insulations which maintain very low boil-off for a prolonged time. Multi-Layer insulation (MLI) finds widespread use in cryogenic applications, designed to effectively restrict heat inleak towards cryogenic fluids. However, recent studies evidenced that exposure to high heat fluxes, such as in the event of a fire accident, can cause the thermal degradation of the insulation material, resulting in the severe collapse of its heat resistance performance. Therefore, the risk of rapid tank pressurization and its connection to the risk of BLEVE may be possible. This study proposes a numerical model to assess the performances of aluminum-based MLI materials under fire conditions. The model offers insights into the total heat transfer rate through the insulation, serving as an indicator of the deterioration's impact on overall heat transfer. The proposed numerical model is validated against experimental data obtained by a High-Temperature Thermal Vacuum Chamber test facility that reproduces fire exposure conditions. The experiments conducted in this study underscore the emergence of pressure build-up within the insulation system, which contributes to increased gas conduction. Furthermore, it demonstrates that the spacer material is not entirely damaged under simulated fire conditions. The numerical calculation also underscores the significance of the modifications in material surface emissivity due to the deterioration process. The innovative approach proposed in this study thus paves the way for the development of improved tools aiming at the stationary and mobile cryogenic tanks behavior (e.g., LNG, LOX, LN2, and LH2) in fire accident scenarios. The model developed may, in perspective, be integrated into both CFD and lumped models for the calculation of the time to failure of cryogenic equipment under external fires. Therefore, this study offers valuable insights to improve the safety of processes and equipment for the storage of cryogenic fluids, thereby supporting emergency response planning in case of fire accidents.</abstract>
    <parentTitle language="eng">Process Safety and Environmental Protection</parentTitle>
    <identifier type="doi">10.1016/j.psep.2024.11.037</identifier>
    <identifier type="issn">0957-5820</identifier>
    <enrichment key="opus_doi_flag">true</enrichment>
    <enrichment key="opus_doi_json">{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,11,14]],"date-time":"2024-11-14T05:25:07Z","timestamp":1731561907826,"version":"3.28.0"},"reference-count":94,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,11,1]],"date-time":"2024-11-01T00:00:00Z","timestamp":1730419200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,11,1]],"date-time":"2024-11-01T00:00:00Z","timestamp":1730419200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,11,11]],"date-time":"2024-11-11T00:00:00Z","timestamp":1731283200000},"content-version":"vor","delay-in-days":10,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Process Safety and Environmental Protection"],"published-print":{"date-parts":[[2024,11]]},"DOI":"10.1016\/j.psep.2024.11.037","type":"journal-article","created":{"date-parts":[[2024,11,13]],"date-time":"2024-11-13T14:11:26Z","timestamp":1731507086000},"update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Non-Combustible MLI Based Insulation Behavior Under Fire Condition - Experimental and Numerical Investigation"],"prefix":"10.1016","author":[{"given":"Aliasghar","family":"HAJHARIRI","sequence":"first","affiliation":[]},{"given":"Robert","family":"EBERWEIN","sequence":"additional","affiliation":[]},{"given":"Davide","family":"CAMPLESE","sequence":"additional","affiliation":[]},{"given":"Giordano Emrys","family":"SCARPONI","sequence":"additional","affiliation":[]},{"given":"Valerio","family":"COZZANI","sequence":"additional","affiliation":[]},{"given":"Frank","family":"OTREMBA","sequence":"additional","affiliation":[]},{"given":"Holger","family":"SEIDLITZ","sequence":"additional","affiliation":[]}],"member":"78","reference":[{"issue":"3","key":"10.1016\/j.psep.2024.11.037_bib1","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1016\/j.jhazmat.2006.09.056","article-title":"The boiling liquid expanding vapour explosion (BLEVE): Mechanism, consequence, assessment, and management","volume":"141","author":"Abbasi","year":"2007","journal-title":"J. Hazard. Mater."},{"key":"10.1016\/j.psep.2024.11.037_bib2","unstructured":"ADR. (2023). United Nations Economic Commission for Europe. Agreement Concerning the International Carriage of Dangerous Goods by Road. doi:https:\/\/doi.org\/10.18356\/9789210014328"},{"issue":"35","key":"10.1016\/j.psep.2024.11.037_bib3","doi-asserted-by":"crossref","first-page":"13308","DOI":"10.1016\/j.ijhydene.2022.12.152","article-title":"Liquid hydrogen storage system for heavy duty trucks: Configuration, performance, cost, and safety","volume":"48","author":"Ahluwalia","year":"2023","journal-title":"Int. J. Hydrogen. Energ."},{"key":"10.1016\/j.psep.2024.11.037_bib4","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1016\/j.jlp.2018.06.001","article-title":"Predicting triggering and consequence of delayed LNG RPT","volume":"55","author":"Aursand","year":"2018","journal-title":"J. Loss Prev. Process Ind."},{"issue":"3","key":"10.1016\/j.psep.2024.11.037_bib5","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1520\/JTE10010J","article-title":"Heat transfer in fibrous materials","volume":"1","author":"Bankvall","year":"1973","journal-title":"J. Test. Eval."},{"issue":"8","key":"10.1016\/j.psep.2024.11.037_bib6","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1016\/0011-2275(90)90235-5","article-title":"Experimental investigations of multilayer insulation","volume":"30","author":"Bapat","year":"1990","journal-title":"Cryogenics"},{"key":"10.1016\/j.psep.2024.11.037_bib7","unstructured":"Barnett, P.G., Gentry, P.J., Jackson, J.D., &amp; Tong, D.K. (1986). Emissivity measurements of liquid sodium and some sodium contaminated steel surfaces."},{"issue":"3","key":"10.1016\/j.psep.2024.11.037_bib8","first-page":"31","article-title":"Emissivity of aluminium and its importance for radiometric measurement","volume":"4","author":"Bartl","year":"2004","journal-title":"Meas. Sci. Rev."},{"issue":"1","key":"10.1016\/j.psep.2024.11.037_bib9","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1016\/0017-9310(85)90033-X","article-title":"On the effect of annealing on total normal emittance of oxidized steel","volume":"28","author":"Bartolini","year":"1985","journal-title":"Int. J. Heat. Mass. Tran."},{"key":"10.1016\/j.psep.2024.11.037_bib10","unstructured":"BASt (Bundesanstalt f\u00fcr Stra\u00dfenwesen). (2015). Zus\u00e4tzliche Technische Vertragsbedingungen und Richtlinien f\u00fcr Ingenieurbauten (ZTV-ING) Teil 5 \u201cTunnelbau\u201d und Teil 3 \u201cMassivbau\u201d, Abschnitt 1 \u201cBeton\u201d."},{"key":"10.1016\/j.psep.2024.11.037_bib11","series-title":"SFPE Handbook of fire protection engineering","author":"Beyler","year":"1995"},{"key":"10.1016\/j.psep.2024.11.037_bib12","first-page":"272","article-title":"Heat-Transfer Model for Fibrous Insulations","author":"Bhattacharyya","year":"1980","journal-title":"ASTM Int."},{"key":"10.1016\/j.psep.2024.11.037_bib13","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.psep.2019.11.023","article-title":"Analysis of BLEVE overpressure using spherical shock theory","volume":"134","author":"Birk","year":"2020","journal-title":"Process Saf. Environ. Prot."},{"key":"10.1016\/j.psep.2024.11.037_bib14","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/j.psep.2020.07.047","article-title":"An overview of test standards and regulations relevant to the fire testing of pressure vessels","volume":"145","author":"Bradley","year":"2021","journal-title":"Process Saf. Environ. Prot."},{"key":"10.1016\/j.psep.2024.11.037_bib15","doi-asserted-by":"crossref","unstructured":"Brunner, T., &amp; Kircher, O. (2016). Cryo-compressed Hydrogen Storage. doi:https:\/\/doi.org\/10.1002\/9783527674268.ch29","DOI":"10.1002\/9783527674268.ch29"},{"key":"10.1016\/j.psep.2024.11.037_bib16","first-page":"415","article-title":"Analysis of high temperature degradation of multi-layer insulation (MLI) systems for liquid hydrogen storage tanks","volume":"99","author":"Camplese","year":"2023","journal-title":"Chem. Eng. Trans."},{"key":"10.1016\/j.psep.2024.11.037_bib17","doi-asserted-by":"crossref","DOI":"10.1016\/j.psep.2024.04.061","article-title":"Modeling the performance of Multilayer Insulation in Cryogenic Tanks undergoing external Fire Scenarios","author":"Camplese","year":"2024","journal-title":"Process Saf. Environ. Prot."},{"key":"10.1016\/j.psep.2024.11.037_bib18","series-title":"In Applied Mathematical Sciences.","doi-asserted-by":"crossref","DOI":"10.1007\/978-1-4419-8524-8","article-title":"The Mathematical Theory of Dilute Gases","author":"Cercignani","year":"1994"},{"key":"10.1016\/j.psep.2024.11.037_bib19","series-title":"Fibrous materials","author":"Chawla","year":"2016"},{"issue":"23","key":"10.1016\/j.psep.2024.11.037_bib20","doi-asserted-by":"crossref","first-page":"8716","DOI":"10.1016\/j.ijhydene.2022.09.114","article-title":"Rethinking \u201cBLEVE explosion\u201d after liquid hydrogen storage tank rupture in a fire","volume":"48","author":"Cirrone","year":"2023","journal-title":"Int. J. Hydrogen Energ."},{"key":"10.1016\/j.psep.2024.11.037_bib21","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/0042-207X(59)90766-3","article-title":"Gaseous heat conduction at low pressures and temperatures","volume":"7","author":"Corruccini","year":"1959","journal-title":"Vacuum"},{"key":"10.1016\/j.psep.2024.11.037_bib22","unstructured":"Coston, R.M., Murray, D.O., &amp; Lambert, L. (1967). A Study On High-Performance Insulation Thermal Design Criteria. Sunnyvale, CA: NASA Contract BAS8-20358, 1."},{"key":"10.1016\/j.psep.2024.11.037_bib23","article-title":"A study of heat-transfer processes in multilayer insulations","volume":"607","author":"Cunnington","year":"1969","journal-title":"4th Thermody. Conf., (p."},{"issue":"15","key":"10.1016\/j.psep.2024.11.037_bib24","first-page":"3441","article-title":"Thermal Stability of Aluminum Alloys","volume":"13","author":"Czerwinski","year":"2020","journal-title":"Mat. 2020"},{"issue":"1","key":"10.1016\/j.psep.2024.11.037_bib25","doi-asserted-by":"crossref","first-page":"10","DOI":"10.2514\/2.6746","article-title":"Heat Transfer in High-Temperature Fibrous Insulation","volume":"17","author":"Daryabeigi","year":"2003","journal-title":"J. Thermophys. Heat. Tr."},{"issue":"4","key":"10.1016\/j.psep.2024.11.037_bib26","doi-asserted-by":"crossref","first-page":"536","DOI":"10.2514\/1.T3616","article-title":"Combined heat transfer in high-porosity high-temperature fibrous insulation: Theory and experimental validation","volume":"25","author":"Daryabeigi","year":"2011","journal-title":"J. Thermophys. Heat. Tr."},{"key":"10.1016\/j.psep.2024.11.037_bib27","unstructured":"Daryabeigi, K., Miller, S.D., &amp; Cunnington, G.R. (2007). Heat transfer in high temperature multilayer insulation. In 5th Euro. Workshop on Thermal Protec. Sys. Hot Struc. Retrieved from \u3008https:\/\/ntrs.nasa.gov\/citations\/20080013560\u3009"},{"key":"10.1016\/j.psep.2024.11.037_bib28","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.cryogenics.2019.01.005","article-title":"Study of the thermal performance of multilayer insulation used in cryogenic transfer lines","volume":"100","author":"Deng","year":"2019","journal-title":"Cryogenics"},{"key":"10.1016\/j.psep.2024.11.037_bib29","first-page":"263","article-title":"Multi-foil Type Thermal Insulation","author":"DeWitt","year":"1968","journal-title":"IEEE T-AES (No. 5, p. 810)"},{"key":"10.1016\/j.psep.2024.11.037_bib30","unstructured":"DIN(1076:1999-11). (1999). Engineering structures in connection with roads - inspection and test. DIN. doi:https:\/\/dx.doi.org\/10.31030\/8499929"},{"key":"10.1016\/j.psep.2024.11.037_bib31","unstructured":"DIN(EN1991-1-2). (2010). Eurocode 1: Actions on structures - Part 1-2: General actions - Actions on structures exposed to fire. doi:https:\/\/doi.org\/10.31030\/1719025"},{"key":"10.1016\/j.psep.2024.11.037_bib32","unstructured":"DIN, &amp; EN1363-2. (1999). Fire resistance tests - Part 2: Alternative and additional procedures;. DIN. doi:https:\/\/doi.org\/10.31030\/8080779"},{"key":"10.1016\/j.psep.2024.11.037_bib33","series-title":"The Navier-Stokes equations: a classification of flows and exact solutions (No.334)","author":"Drazin","year":"2006"},{"key":"10.1016\/j.psep.2024.11.037_bib34","doi-asserted-by":"crossref","unstructured":"Eberwein, R., Hajhariri, A., Camplese, D., Scarponi, G.E., Cozzani, V., &amp; Otremba, F. (2023). A comparative study on insulation materials in tanks for the storage of cryogenic fluids in fire incidents. In ASME Int. Mech. Eng. Cong. Expo., (Vol. 87707, p. V013T14A004). doi:https:\/\/doi.org\/10.1115\/IMECE2023-110470","DOI":"10.1115\/IMECE2023-110470"},{"key":"10.1016\/j.psep.2024.11.037_bib35","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1016\/j.psep.2024.04.131","article-title":"Experimental investigation on the behavior of thermal super insulation materials for cryogenic storage tanks in fire incidents","author":"Eberwein","year":"2024","journal-title":"Process Saf. Environ. Prot."},{"key":"10.1016\/j.psep.2024.11.037_bib36","unstructured":"ECE. (2022). R-110, Part II - Approval of vehicles with regard to the installation of specific components of an approved type for the use of compressed natural gas (CNG) and\/or liquefied natural gas (LNG) in their propulsion system. UNITED NATIONS. Retrieved from \u3008https:\/\/unece.org\/sites\/default\/files\/2022-07\/R110r6e.pdf\u3009"},{"key":"10.1016\/j.psep.2024.11.037_bib37","unstructured":"Fesmire, J., &amp; Swangerl, A. (2019). Advanced cryogenic insulation systems. Proceedings of the 25th IIR International Congress of Refrigeration:. Montr\u00e9al. doi:http:\/\/dx.doi.org\/10.18462\/iir.icr.2019.1732"},{"key":"10.1016\/j.psep.2024.11.037_bib38","unstructured":"Gebhart, B. (1988). Buoyancy-induced flows and transport. Hemisphere Pub."},{"issue":"21","key":"10.1016\/j.psep.2024.11.037_bib39","doi-asserted-by":"crossref","first-page":"18358","DOI":"10.1021\/acsomega.3c01072","article-title":"Strategies to improve the performance of hydrogen storage systems by liquefaction methods: a comprehensive review","volume":"8","author":"Ghorbani","year":"2018","journal-title":"ACS omega"},{"issue":"1","key":"10.1016\/j.psep.2024.11.037_bib40","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1016\/j.ijhydene.2017.10.128","article-title":"Study of key parameters in modeling liquid hydrogen release and dispersion in open environment","volume":"43","author":"Giannissi","year":"2018","journal-title":"Int. J. Hydrogen. Energ."},{"key":"10.1016\/j.psep.2024.11.037_bib41","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1016\/j.psep.2023.09.044","article-title":"Flame behavior and temperature distribution of coupled fire induced by the interaction of hydrogen jet flame and pool flame","volume":"179","author":"Gong","year":"2023","journal-title":"Process Saf. Environ. Prot."},{"key":"10.1016\/j.psep.2024.11.037_bib42","unstructured":"GTR-13. (2013). Global technical regulation No. 13 on hydrogen and fuel cell. ECE-TRANS-180a13e. Retrieved from \u3008https:\/\/unece.org\/fileadmin\/DAM\/trans\/main\/wp29\/wp29wgs\/wp29gen\/wp29registry\/ECE-TRANS-180a13e.pdf\u3009"},{"key":"10.1016\/j.psep.2024.11.037_bib43","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1016\/j.psep.2023.04.021","article-title":"CFD-modelling of large-scale LH2 release and explosion experiments","volume":"174","author":"Hansen","year":"2023","journal-title":"Process Saf. Environ. Prot."},{"issue":"18","key":"10.1016\/j.psep.2024.11.037_bib44","first-page":"633","article-title":"Vapor pressure curves and triple points in the temperature region from 14 to 90 k Abs","volume":"37","author":"Henning","year":"1936","journal-title":"Phys. Z."},{"key":"10.1016\/j.psep.2024.11.037_bib45","series-title":"Heat transfer","author":"Holman","year":"1990"},{"key":"10.1016\/j.psep.2024.11.037_bib46","first-page":"15","article-title":"Induction heating of thin nonmagnetic sheets in transverse time-variable magnetic field","author":"Hrbek","year":"2015","journal-title":"Acta Tech"},{"issue":"12","key":"10.1016\/j.psep.2024.11.037_bib47","doi-asserted-by":"crossref","first-page":"1364","DOI":"10.1016\/j.eng.2020.04.016","article-title":"A review of technical advances, barriers, and solutions in the power to hydrogen (P2H) roadmap","volume":"6","author":"Hu","year":"2020","journal-title":"Engineering"},{"issue":"3","key":"10.1016\/j.psep.2024.11.037_bib48","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1080\/00295450.2017.1311120","article-title":"Total hemispherical emissivity of SS 316L with simulated very high temperature reactor surface conditions","volume":"198","author":"Hunnewell","year":"2017","journal-title":"Nucl. Technol."},{"key":"10.1016\/j.psep.2024.11.037_bib49","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1016\/j.psep.2021.03.027","article-title":"Numerical simulation of LNG tanks exposed to fire","author":"Iannaccone","year":"2021","journal-title":"Process Saf. Environ. Prot."},{"key":"10.1016\/j.psep.2024.11.037_bib50","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1007\/BF01637703","article-title":"Influence of surface treatments on the total normal emittance of AISI316 stainless steel","volume":"14","author":"Isetti","year":"1980","journal-title":"W\u00e4rme- und Stoff\u00fcbertragung"},{"issue":"2","key":"10.1016\/j.psep.2024.11.037_bib51","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/0021-8502(88)90219-4","article-title":"The mean free path in air","volume":"19","author":"Jennings","year":"1988","journal-title":"J. Aerosol. Sci."},{"key":"10.1016\/j.psep.2024.11.037_bib52","first-page":"1519","article-title":"Thermal analysis of low layer density multilayer insulation test results","volume":"1434","author":"Johnson","year":"2012"},{"key":"10.1016\/j.psep.2024.11.037_bib53","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1016\/j.cryogenics.2017.07.002","article-title":"Transmissivity Testing of Multilayer Insulation at Cryogenic Temperatures","volume":"86","author":"Johnson","year":"2017","journal-title":"Cryogenics"},{"key":"10.1016\/j.psep.2024.11.037_bib54","unstructured":"Johnson, W.R., &amp; Sprague, E.L. (1968). Analytical Investigation of Thermal Degradation of High-performance Multilayer Insulation in the Vicinity of a Penetration (No. NASA-TN-D-4778). Cleveland, OH.: National Aeronautics and Space Administration."},{"key":"10.1016\/j.psep.2024.11.037_bib55","series-title":"Heat load resistance of cryogenic storage tanks \u2013 Results of LNG Safety Program TNO Report no. TNO 2016 R10352","author":"Kamperveen","year":"2016"},{"issue":"3","key":"10.1016\/j.psep.2024.11.037_bib56","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1071\/CH9510305","article-title":"The temperature dependence of the thermal conductivity of air","volume":"4","author":"Kannuluik","year":"1951","journal-title":"Aust. J. Chem."},{"key":"10.1016\/j.psep.2024.11.037_bib57","series-title":"Microflows and nanoflows: fundamentals and simulation","author":"Karniadakis","year":"2006"},{"key":"10.1016\/j.psep.2024.11.037_bib58","unstructured":"Kundu, P.K., Cohen, I.M., &amp; Dowling, D.R. (2016). Fluid Mechanics. Elsevier, 6. doi:https:\/\/doi.org\/10.1016\/C2012-0-00611-4"},{"issue":"3","key":"10.1016\/j.psep.2024.11.037_bib59","doi-asserted-by":"crossref","DOI":"10.2514\/2.6356","article-title":"Heat transfer in fibrous insulations: comparison of theory and experiment","volume":"12","author":"Lee","year":"1998","journal-title":"J. Thermophys. Heat. Tr."},{"key":"10.1016\/j.psep.2024.11.037_bib60","first-page":"240","article-title":"Influence of vacuum level on insulation thermal performance for LNG cryogenic road tankers","volume":"240","author":"Lisowski","year":"2018","journal-title":"International Conference on Computational Heat, Mass and Momentum Transfer (ICCHMT 2018)"},{"key":"10.1016\/j.psep.2024.11.037_bib61","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1016\/j.applthermaleng.2015.12.084","article-title":"Thermal performance of foam\/MLI for cryogenic liquid hydrogen tank during the ascent and on orbit period","volume":"98","author":"Liu","year":"2016","journal-title":"Appl. Therm. Eng."},{"key":"10.1016\/j.psep.2024.11.037_bib62","doi-asserted-by":"crossref","first-page":"1683","DOI":"10.1007\/978-1-4615-2522-6_206","article-title":"Layer by layer MLI calculation using a separated mode equation","volume":"39","author":"McIntosh","year":"1994","journal-title":"Adv. Cryog. Eng."},{"key":"10.1016\/j.psep.2024.11.037_bib63","series-title":"Review of current state of the art and key design issues with potential solutions for liquid hydrogen cryogenic storage tank structures for aircraft applications NASA\/TM\u20142006-214346","author":"Mital","year":"2006"},{"key":"10.1016\/j.psep.2024.11.037_bib64","first-page":"418","article-title":"Development of a new multi-layer insulation blanket with non-interlayer-contact spacer for space cryogenic mission","author":"Miyakita","year":"2014","journal-title":"Cryogenics"},{"key":"10.1016\/j.psep.2024.11.037_bib65","volume":"69","author":"NIST","year":"2019","journal-title":"National Institute for Standards and Technology, Standard Reference Database Number"},{"issue":"12","key":"10.1016\/j.psep.2024.11.037_bib66","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1016\/j.cryogenics.2005.06.009","article-title":"Thermal performance of multilayer insulation around a horizontal cylinder","volume":"45","author":"Ohmori","year":"2005","journal-title":"Cryogenics"},{"issue":"5","key":"10.1016\/j.psep.2024.11.037_bib67","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/0360-3199(95)00092-5","article-title":"Aspects of safety and acceptance of LH2 tank systems in passenger cars.","volume":"21","author":"Pehr","year":"1996","journal-title":"Int. J. Hydrogen Energ."},{"key":"10.1016\/j.psep.2024.11.037_bib68","first-page":"2169","article-title":"Experimental examinations on the worst-case behaviour of LH2\/LNG tanks for passenger cars","author":"Pehr","year":"1996","journal-title":"Proc. 11th World Hydrogen Energy Conference"},{"key":"10.1016\/j.psep.2024.11.037_bib69","series-title":"In Liquid Hydrogen: Fuel of the Future","first-page":"117","article-title":"Liquid hydrogen as fuel","author":"Peschka","year":"1992"},{"key":"10.1016\/j.psep.2024.11.037_bib70","first-page":"662","article-title":"Measuring the gas pressure within a high- performance insulation blanket","volume":"13","author":"Price","year":"1967","journal-title":"Adv. Cryog. Eng."},{"key":"10.1016\/j.psep.2024.11.037_bib71","first-page":"3","article-title":"Introduction to aluminum and aluminum alloys. In Properties and selection: nonferrous alloys and special-purpose materials","author":"Rooy","year":"1990","journal-title":"ASM International."},{"issue":"1","key":"10.1016\/j.psep.2024.11.037_bib72","article-title":"Analysis of gas thermal conductivity at low pressures using a mathematical-physical model","volume":"2382","author":"\u0160aback\u00e1","year":"2022","journal-title":"In J. of Phys. v: Conference Series"},{"key":"10.1016\/j.psep.2024.11.037_bib73","first-page":"119","article-title":"Explosion (overpressure) driven domino effect","volume":"5","author":"Salzano","year":"2021"},{"key":"10.1016\/j.psep.2024.11.037_bib74","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1016\/j.psep.2023.12.048","article-title":"Modelling the behaviour of LPG tanks exposed to partially engulfing pool fires.","volume":"182","author":"Scarponi","year":"2024","journal-title":"Process Saf. Environ. Prot."},{"key":"10.1016\/j.psep.2024.11.037_bib75","first-page":"228","volume":"2","author":"Sherman","year":"1963","journal-title":"A survey of experimental results and methods for the transition regime of rarefied gas dynamics"},{"issue":"6-7","key":"10.1016\/j.psep.2024.11.037_bib76","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.1016\/j.ijheatmasstransfer.2003.08.012","article-title":"Studies on high-temperature multilayer thermal insulations","volume":"47","author":"Spinnler","year":"2004","journal-title":"Int. J. Heat Mass Tran. (IJHMT)"},{"key":"10.1016\/j.psep.2024.11.037_bib77","series-title":"Glass-fibre Directory and Databook","author":"Starr","year":"1996"},{"issue":"1","key":"10.1016\/j.psep.2024.11.037_bib78","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1063\/1.555749","article-title":"The thermal conductivity of fluid air","volume":"14","author":"Stephan","year":"1985","journal-title":"J. Phys. Chem. Ref. Data"},{"key":"10.1016\/j.psep.2024.11.037_bib79","series-title":"Degradation of a Multilayer Insulation Due to a Seam and a Penetration (No. E-8622)","author":"Sumner","year":"1976"},{"issue":"12","key":"10.1016\/j.psep.2024.11.037_bib80","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1016\/j.cryogenics.2009.09.003","article-title":"Experimental study of the influences of degraded vacuum on multilayer insulation blankets","volume":"49","author":"Sun","year":"2009","journal-title":"Cryogenics"},{"key":"10.1016\/j.psep.2024.11.037_bib81","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1016\/S0065-2717(08)70065-0","article-title":"Cryogenic insulation heat transfer","volume":"9","author":"Tien","year":"1973","journal-title":"Adv. Heat Transf."},{"key":"10.1016\/j.psep.2024.11.037_bib82","first-page":"718","article-title":"Radiation heat transfer in multilayer insulation having perforated shields","author":"Tien","year":"1974","journal-title":"AIAA 8th Thermophysics conference"},{"key":"10.1016\/j.psep.2024.11.037_bib83","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.ress.2011.11.002","article-title":"Mitigation of fire damage and escalation by fireproofing: A risk-based strategy","volume":"105","author":"Tugnoli","year":"2012","journal-title":"Reliab. Eng. Syst. Saf"},{"issue":"3","key":"10.1016\/j.psep.2024.11.037_bib84","first-page":"179","article-title":"On the existence of global solutions of mixed problem for non-linear Boltzmann","volume":"50","author":"Ukai","year":"1974","journal-title":"Proceedings of the Japan Academy"},{"key":"10.1016\/j.psep.2024.11.037_bib85","first-page":"535","article-title":"Cryogenic Hydrogen Storage Tanks Exposed to Fires: a CFD study","author":"Ustolin","year":"2022","journal-title":"Chem. Eng. Trans."},{"key":"10.1016\/j.psep.2024.11.037_bib86","first-page":"547","article-title":"Medium-scale tests to investigate the possibility and effects of BLEVEs of storage vessels containing liquified hydrogen","volume":"90","author":"van Wingerden","year":"2022","journal-title":"17th European Federation of Chemical Engineering (EFCE)"},{"issue":"6","key":"10.1016\/j.psep.2024.11.037_bib87","first-page":"961","article-title":"Heat Transfer by Gas Conduction and Radiation in Fibrous Insulations","volume":"74","author":"Verschoor","year":"1952","journal-title":"T. Am. Sco. Mech. Eng."},{"key":"10.1016\/j.psep.2024.11.037_bib88","doi-asserted-by":"crossref","DOI":"10.1016\/j.applthermaleng.2021.116569","article-title":"Characterization and monitoring of vacuum pressure of tank containers with multilayer insulation for cryogenic clean fuels storage and transportation","volume":"187","author":"Wang","year":"2021","journal-title":"Appl. Therm. Eng."},{"issue":"38","key":"10.1016\/j.psep.2024.11.037_bib89","doi-asserted-by":"crossref","first-page":"17118","DOI":"10.1016\/j.ijhydene.2016.06.254","article-title":"Correlations for calculating heat transfer of hydrogen pool boiling","volume":"41","author":"Wang","year":"2016","journal-title":"Int. J. Hydrogen Energ."},{"key":"10.1016\/j.psep.2024.11.037_bib90","series-title":"Handbook of cryogenic engineering","author":"Weisend","year":"1998"},{"issue":"9","key":"10.1016\/j.psep.2024.11.037_bib91","doi-asserted-by":"crossref","first-page":"5779","DOI":"10.3390\/app13095779","article-title":"Inversion of Interlayer Pressure in High-Vacuum Multilayer Insulation Structures for Cryogen Storage Using Extreme Learning Machine","volume":"13","author":"Wu","year":"2023","journal-title":"Appl. Sci."},{"key":"10.1016\/j.psep.2024.11.037_bib92","first-page":"2338","article-title":"Hydrogen fuel tank fire exposure burst test","volume":"114","author":"Zalosh","year":"2005","journal-title":"SAE Int. J. Passeng. Cars Mech. Syst."},{"key":"10.1016\/j.psep.2024.11.037_bib93","series-title":"Fibrous-Glass Board, for Thermal Conductivity from 280 K to 340 K, Special Publication (NIST SP)","author":"Zarr","year":"2011"},{"issue":"8","key":"10.1016\/j.psep.2024.11.037_bib94","doi-asserted-by":"crossref","DOI":"10.1088\/2053-1591\/aa7fc9","article-title":"Effect of surface oxidation on emissivity properties of pure aluminum in the near infrared region","volume":"4","author":"Zhang","year":"2017","journal-title":"Mater. Res. Express"}],"container-title":["Process Safety and Environmental Protection"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0957582024014502?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0957582024014502?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,11,13]],"date-time":"2024-11-13T14:11:53Z","timestamp":1731507113000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0957582024014502"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11]]},"references-count":94,"alternative-id":["S0957582024014502"],"URL":"http:\/\/dx.doi.org\/10.1016\/j.psep.2024.11.037","relation":{},"ISSN":["0957-5820"],"issn-type":[{"value":"0957-5820","type":"print"}],"subject":[],"published":{"date-parts":[[2024,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Non-Combustible MLI Based Insulation Behavior Under Fire Condition - Experimental and Numerical Investigation","name":"articletitle","label":"Article Title"},{"value":"Process Safety and Environmental Protection","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.psep.2024.11.037","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Author(s). Published by Elsevier Ltd on behalf of Institution of Chemical Engineers.","name":"copyright","label":"Copyright"}]}}</enrichment>
    <enrichment key="opus_crossrefDocumentType">journal-article</enrichment>
    <enrichment key="opus_crossrefLicence">https://www.elsevier.com/tdm/userlicense/1.0/</enrichment>
    <enrichment key="opus_import_origin">crossref</enrichment>
    <enrichment key="opus_doiImportPopulated">PersonAuthorFirstName_1,PersonAuthorLastName_1,PersonAuthorFirstName_2,PersonAuthorLastName_2,PersonAuthorFirstName_3,PersonAuthorLastName_3,PersonAuthorFirstName_4,PersonAuthorLastName_4,PersonAuthorFirstName_5,PersonAuthorLastName_5,PersonAuthorFirstName_6,PersonAuthorLastName_6,PersonAuthorFirstName_7,PersonAuthorLastName_7,PublisherName,TitleMain_1,Language,TitleParent_1,PublishedYear,IdentifierIssn,Enrichmentopus_crossrefLicence</enrichment>
    <enrichment key="BTU">nicht an der BTU erstellt / not created at BTU</enrichment>
    <enrichment key="Referiert">Beitrag ist referiert / Article peer-reviewed</enrichment>
    <enrichment key="Publikationsweg">Open Access</enrichment>
    <enrichment key="opus.source">doi-import</enrichment>
    <author>
      <firstName>Aliasghar</firstName>
      <lastName>Hajhariri</lastName>
    </author>
    <submitter>
      <firstName>René</firstName>
      <lastName>Wickmann</lastName>
    </submitter>
    <author>
      <firstName>Robert</firstName>
      <lastName>Eberwein</lastName>
    </author>
    <author>
      <firstName>Davide</firstName>
      <lastName>Camplese</lastName>
    </author>
    <author>
      <firstName>Giordano Emrys</firstName>
      <lastName>Scarponi</lastName>
    </author>
    <author>
      <firstName>Valerio</firstName>
      <lastName>Cozzani</lastName>
    </author>
    <author>
      <firstName>Frank</firstName>
      <lastName>Otremba</lastName>
    </author>
    <author>
      <firstName>Holger</firstName>
      <lastName>Seidlitz</lastName>
    </author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Multi-Layer Insulation (MLI)</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Cryogenic Vessels</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Liquefied Hydrogen</value>
    </subject>
    <collection role="institutes" number="3422">FG Polymerbasierter Leichtbau</collection>
  </doc>
</export-example>