@misc{MartinaKammererPrantletal., author = {Martina, Georgieva and Kammerer, Sarah and Prantl, Lukas and Jung, Friedrich and Stroszczynski, Christian and Jung, Ernst Michael}, title = {Imaging of breast implant and implant-associated complications: Capsular contracture and intraor extracapsular rupture}, series = {Clinical Hemorheology and Microcirculation}, volume = {76}, journal = {Clinical Hemorheology and Microcirculation}, number = {2}, issn = {1875-8622}, doi = {10.3233/CH-209218}, pages = {221 -- 231}, abstract = {BACKGROUND: In recent years, follow-up after breast reconstruction with silicone implants and the detection of complications have been relieved by the possibility of improved diagnostic methods. METHODS: Between January 2015 and December 2019 a total of 40 patients (29-84 years) with silicone implants were included in this retrospective study. The implants were examined clinically and with modern imaging: general ultrasound imaging (US), magnetic resonance imaging (MRI), high resolution computed tomography (CT) and positron emission tomography -computed tomography (PET-CT). If necessary, a histological/cytological sample was taken. The breast implants were assessed by three radiologists specialized in breast imaging. The grade of capsular contracture was classified according to the Baker classification. RESULTS: All 40 women obtained a clinical examination and an US diagnostic to identify early and more common complications such as implant folding and capsular fibrosis. Depending on the clinical examination and ultrasound findings additional MRI (n = 10), CT (n = 9) and/or PET-CT (n = 2) were performed. 16 patients had implants folding proven with US (n = 16), MRI (n = 6) and CT (n = 1). The grade of capsular fibrosis was determined according to the Baker classification. The following results were obtained in our study: 25 breast implants with Baker grade I and eleven breast implants with Baker grade II, both proven with US; one breast implants with Baker grade III and one breast implant with Baker grade IV, proven with US (n = 2), MRI (n = 1) and CT (n = 1). One patient had intracapsular rupture and one patient had extracapsular rupture, both detected on CT and surgically proven. No patient had a silicone accumulation in the lymph nodes. One patient had pathologically enlarged axillary lymph nodes, which were evaluated as inflammatory changes in PET-CT. Long-term complications such as the development of malignant breast tumors could not be observed. CONCLUSION: To detect early complications after breast implant surgery, a regular clinical examination is indispensable. Imaging methods complement each other and if they are used multimodal, it is easier to identify early complications. Modern diagnostic modalities like ultrasound and magnetic resonance imaging expand the spectrum and improve diagnostic safety.}, language = {en} } @misc{JungWertheimerPutzetal., author = {Jung, Ernst Michael and Wertheimer, T. and Putz, F. J. and Jung, Friedrich and Kammerer, Sarah and Pregler, B. and Luerken, L. and Stroszczynski, Christian and Beyer, L.}, title = {Contrast enhanced ultrasound (CEUS) with parametric imaging and time intensity curve analysis (TIC) for evaluation of the success of prostate arterial embolization (PAE) in cases of prostate hyperplasia}, series = {Clinical Hemorheology and Microcirculation}, volume = {76}, journal = {Clinical Hemorheology and Microcirculation}, number = {2}, issn = {1875-8622}, doi = {10.3233/CH-209202}, pages = {143 -- 153}, abstract = {AIM: To evaluate the use of dynamic contrast enhanced ultrasound (CEUS) with parametric color-coded imaging and time intensity curve analysis (TIC) for planning and follow-up after prostate arterial embolization (PAE). MATERIAL/METHOD: Before and after selective iliacal embolization by PAE with a follow up of 6 months 18 male patients (43-78 years, mean 63±3.5 years) with histopathological proven benign prostate hyperplasia were examined by one experienced examiner. A multifrequency high resolution probe (1-6 MHz) was used for transabdominal ultrasound and CEUS with bolus injections of 2.4 ml sulphur-hexafluoride microbubbles. Independent evaluation of color-coded parametric imaging before and after PAE by in PACS stored DICOM loops from arterial phase (10-15 s) up to 1min were performed. Criteria for successful treatment were reduction of early arterial enhancement by changes of time to peak (TTP) and area under the curve (AUC) by measurements in 8 regions of interest (ROI) of 5 mm in diameter at the margin and in the center and changes from hyperenhancement in parametric imaging (perfusion evaluation of arterial enhancement over 15 s) from red and yellow to blue and green by partial infarctions. Reference imaging method was the contrast high resolution 3 tesla magnetic resonance tomography (MRI) using 3D vibe sequences before and after PAE and for the follow up after 3 and 6 months. RESULTS: PAE was technically and clinically successful in all 18 patients with less clinical symptoms and reduction of the gland volume. In all cases color-coded CEUS parametric imaging was able to evaluate partial infarction after embolization with changes from red and yellow to green and blue colors in the embolization areas. Relevant changes could be evaluated for TIC-analysis of CEUS with reduced arterial enhancement in the arterial phase and prolonged enhancement of up to 1 min with significant changes (p = 0.0024). The area under the curve (AUC) decreased from 676±255.04 rU (160 rU-1049 rU) before PAE to 370.43±255.19 rU (45 rU-858 rU) after PAE. Time to peak (TTP) did not change significantly (p = 0.6877); TTP before PAE was 25.82±9.04 s (12.3 s-42.5 s) and after PAE 24.43±9.10 s (12-39 s). Prostate volume decreased significantly (p = 0.0045) from 86.93±34.98 ml (30-139 ml) before PAE to 50.57±26.26 ml (19-117 ml) after PAE. There were no major complications and, in most cases (14/18) a volume reduction of the benign prostate hyperplasia occurred. CONCLUSION: Performed by an experienced examiner CEUS with parametric imaging and TIC-analysis is highly useful to further establish prostatic artery embolization (PAE) as a successful minimal invasive treatment of benign prostatic hyperplasia.}, language = {en} } @misc{JungKammererBrandensteinetal., author = {Jung, Ernst Michael and Kammerer, Sarah and Brandenstein, M. and Putz, F. J. and Stroszczynski, Christian and Jung, Friedrich}, title = {High resolution flow (HR Flow) and Glazing Flow in cases of hepatic flow changes: Comparison to color-coded doppler sonography (CCDS)}, series = {Clinical Hemorheology and Microcirculation}, volume = {79}, journal = {Clinical Hemorheology and Microcirculation}, number = {1}, issn = {1875-8622}, doi = {10.3233/CH-219102}, pages = {3 -- 17}, abstract = {AIM: To evaluate the possibilities of flow detection using high resolution flow (HR Flow) and Glazing Flow technique in patients with liver parenchymal changes and flow changes in comparison to color-coded Doppler sonography (CCDS). MATERIAL AND METHODS: All examinations were performed using a multi frequency matrix convex probe with high resolution technique (SC6-1U/Resona7, Mindray, Shenzhen, China) by one experienced examiner to evaluate the venous, portal venous and arterial liver flow with digital documentation of the dynamic flow parameters like peak systolic flow, end-diastolic flow and resistance index. For liver parenchymal stiffness changes shear wave elastography was performed with at least 10 measurements. By two independent readers an elevation was performed to evaluate the image quality and the degree of flow artefacts, from 0 = not available to 5 points with excellent image quality without flow artefacts. RESULTS: All 40 patients (24 men, 16 women, age 27-83 years, mean 56±5 years) showed morphology changes from B-Mode of the liver parenchyma to inhomogeneous tissue with higher stiffness evaluated by the shear wave elastography (1.45 m/s up to 2.79 m/s±1.79 m/s, considering F1 up to F4 fibrosis) and in 15 cases histopathologically proven liver cirrhosis. In 9 cases after non-acute thrombosis flow reduction of the portal vein was the reason for the diameter less than 5 mm. Flow parameters for the venous flow were between 8 cm/s up to 29 cm/s, mean 14±4 cm/s, for the hepatic portal vein 5 cm/s up to 57 cm/s, mean 17±5 cm/s, for the hepatic artery systolic flow between 50 cm/s up to 127±33 cm/s, end-diastolic flow from 22 cm/s up to 47±8 cm/s. Resistance index for the hepatic artery was between 0.41 up to 0.73, mean 0.67±0.25. The image quality for CCDS over all cases was evaluated for CCDS between 1 up to 4. The mean quality was 2.5±0.5, for HR Flow in combination with Glazing Flow 3±0.5, with significant differences for the 2 readers (P < 0.01). CONCLUSION: Combination of HR Flow with Glazing Flow could be helpful to evaluate morphological und hemodynamic changes of liver arterial flow, portal venous and venous flow. Reduction of flow artefacts in combination with a higher image quality could be helpful for optimizing the digital measurements also for follow up examinations.}, language = {en} }